Wells HOLMAN MM14 Скачать руководство пользователя страница 2

INSTALLATION 

NOTE:

  DO NOT discard 

the carton or other packing 
materials until you have 
inspected the hood for hidden 
damage and tested it for 
proper operation. 
Refer to 

SHIPPING DAMAGE 

CLAIM PROCEDURE 

on the 

inside front cover of the     
owners manual. 
 

 

CAUTION! 

RISK OF  
PERSONAL INJURY               

              AND PROPERTY  
              DAMAGE 
 

Unplug conveyor warmer and 
allow to cool before beginning 
installation.

 

 
 
 
 

UNPACKING & INSPECTION 

 

This instruction supplements the installation instructions in Owners 
Manual for WVSW (p/n305812) Carefully read all instructions in the 
owners manual and this instruction before starting any installation. 

 

Carefully remove the accessories from the carton.   

 

Remove all protective plastic film and packing materials from the hood 
accessories performing any installation procedure. 

 

Carefully account for all components and accessories before 
discarding packing materials.   

 

COMPONENTS IN THIS KIT: 
        ADAPTER TOP FOR HOLMAN QT14 WARMER 
        ENTRY CANOPY 
        EXIT CANOPY 

 

COMPONENTS SHIPPED WITH HOOD: 
        HIGH EFFICIENCY FILTER 
        CHARCOAL FILTER 
 

SETUP 

 

The Holman QT14 Sandwich Warmer requires an adapter top for 
mounting the hood.  Place adapter top on oven before setting hood in 
place.  The Holman MM14 Sandwich Warmer does not require an 
adapter top. 
 
Orient hood so that power switch is on the same side as the power 
switch of the warmer.  Center hood over the body of the warmer as 
shown in 

Fig. 2 

below: 

 
 
 
 
 
 
 
 
 
 
 
 
 

       

Fig. 2  Hood installation on warmer

 

 

Check high efficiency filter and charcoal filter for proper installation.  
Charcoal filter slides into clips on the high efficiency filter.  Airflow 
marks must point "up". 

 

Attach entry and exit canopies to pins on sides of hood.  Canopies are 
interchangeable and may be mounted at either end, depending on the 
direction of product flow.  The short  canopy is the ENTRY canopy, and 
the long canopy is the EXIT canopy. 
 
Maintain required clearances of at least 6" between the appliance and 
adjacent  combustible surfaces.

 