Wells G-136 Скачать руководство пользователя страница 6

AGENCY LISTING INFORMATION

INSTALLATION

4

NOTE:

  DO NOT discard

the carton or other packing

materials until you have

inspected the appliance for

hidden damage and tested it 

for proper operation.

Refer to 

SHIPPING DAMAGE 

CLAIM PROCEDURE 

on the 

inside front cover of this

manual.

IMPORTANT:  

This is a  

GENERAL GUIDE.  For 

specific equipment and 

cutout dimensions, and other 

installation details, refer to 

the 

Installation Instructions

 

supplied with the appliance.

IMPORTANT:

  Water damage 

caused by failure to set 

Wellsloks, failure to install 

gasket, or failure to seal flange 

to counter is 

NOT

 covered by 

warranty.

UNPACKING & INSPECTION

Carefully remove the appliance from the carton.  Remove all protective 

plastic film, packing materials and accessories from the appliance      

before connecting electrical power or otherwise performing any          

installation procedure.
Carefully read all instructions in this manual and the 

Installation         

Instruction Sheet

 packed with the appliance before starting any          

installation.
Read and understand all attached labels and diagrams.
Carefully account for all components and accessories before discarding 

packing materials.  Store all accessories in a convenient place for later 

use.

CUT-OUT AND INSTALLATION

Cutouts

a. 

Griddles may be installed in METAL COUNTERS ONLY.

b. 

Cutout dimensions for griddles and control panels are listed on 

the 

Installation Instructions

 provided with the griddle.

c. 

Refer to the 

Installation Instructions 

for Underwriters          

Laboratories 

Conditions of Acceptability.

Mounting the griddle:

a. 

Verify that provided sealants are applied to the under side of 

the griddle top flange prior to setting the unit into the cutout.

b. 

After installation, verify that the tabs on the Wellsloks are 

turned out to lock the appliance into the counter (see Fig. 2).

c. 

Apply a thin bead of food-grade silicone sealant around the 

flange to seal it to the counter.

Refer to the

 Installation Instructions

 for required clearances.  Maintain 

required clearances between the appliance and adjacent combustible 

and non-combustible surfaces.

Sufficient overhead clearance must be provided to allow the element 

assembly to be raised.  Refer to the 

Installation Instruction Sheet 

for 

required clearances.

Avoid storing flammable or combustible materials near the appliance.  

This includes gasoline and other fuels, mops, rags and wrapping paper.

Fig. 2  Set the Wellslloks

This appliance conforms to NSF Standard 4 for sanitation only if        

installed in accordance with the supplied 

Installation Instructions.

This appliance is Underwriters Laboratory recognized (     ).  Since this 

appliance is only a single component of a complete installation, the   

finished installation of this        unit requires additional evaluations to 

Underwriters Laboratory standards.
Refer to 

Installation Instructions

 included with the appliance for                

Underwriters Laboratories conditions of acceptability, electrical          

requirements and other installation concerns.

STD 4

11

1  p/n 

2M-303340

   OpManual Built-In Electric Griddles

Содержание G-136

Страница 1: ...RAINING OPERATORS of this appliance Additional manuals are available from your WELLS DEALER THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR INSTALLING THIS APPLIANCE Contact your WELLS...

Страница 2: ...the note of loss or damage is signed by the delivery person 2 FILE CLAIM FOR DAMAGE IMMEDIATELY Regardless of the extent of the damage 3 CONCEALED LOSS OR DAMAGE if damage is unnoticed until the merch...

Страница 3: ...ppliance and to use and care for the appliance in a manner which will ensure its optimum performance TABLE OF CONTENTS SPECIFICATIONS STANDARD GRIDDLES INTRODUCTION 1 MODEL VOLTS WATTS AMPS 3 AMPS L1...

Страница 4: ...ividually controllable Dial position is an indication of the temperature setting The actual temperature at the griddle surface will vary depending upon the initial type and temperature of the product...

Страница 5: ...ing any wiring diagrams schematics parts breakdown illustrations and or adjustment procedures is intended for use by qualified technical personnel Any procedure which requires the use of tools must be...

Страница 6: ...ith the griddle c Refer to the Installation Instructions for Underwriters Laboratories Conditions of Acceptability Mounting the griddle a Verify that provided sealants are applied to the under side of...

Страница 7: ...to the wrong voltage or phase is NOT covered by warranty ELECTRICAL INSTALLATION Refer to the nameplate Verify the electrical service power Voltage and phase must match the nameplate specifications C...

Страница 8: ...USING THE GRIDDLE Check the chart on page 7 for recommended cooking temperatures Turn temperature control knob to the desired temperature The heating indicator light will glow while the griddle is hea...

Страница 9: ...tries to compensate for heat lost to the low section Teppan griddle JG 246UL heats in the center two quadrants only The outer two quadrants are used for holding prepared food at temperature RECOMMEND...

Страница 10: ...ove all grease and food waste from the grease trough by pushing it down the waste hole and into the grease drawer After scraping all cooking waste from grease trough into the grease drawer take the gr...

Страница 11: ...e drawer After scraping all cooking waste from grease trough into the grease drawer take the grease drawer to kitchen cleaning area and properly dispose of all waste a Clean drawer with hot water and...

Страница 12: ...set to desired temperature Set to desired temperature Damaged internal component Contact Wells Authorized Service Agency for repairs Griddle drips grease Grease drawer full or not installed Empty grea...

Страница 13: ...G136 Cabinet Electrical BUILT IN ELECTRIC GRIDDLE MODEL G136 CABINET ELECTRICAL 208 240V and 480V KNOB 2R 50259 IL1909 Rev B PL111 MODEL G136 GG136 PG136 CABINET ELECTRICAL 208 240V 380 415V and 480V...

Страница 14: ...N ELECTRIC GRIDDLE MODEL G136 G136 HEATING ELEMENTS 208 240V and 480V 12 EXPLODED VIEW G136 Heating Elements GRIDDLE REF shown inverted FRONT IL1908 Rev B PL111 28 29 30 31 32 33 34 35 36 37 38 MODEL...

Страница 15: ...1 16 X 2 X 15FT 0 4 G136 11 2C 31053 NUT 8 32 KEPS MS NICKEL 8 G136 G136 480V 9 G136 400 12 2C 31734 SCREW 8 32X2 1 4 SL RDHD 2 G136 13 G7 31989 SHROUD DRWR G13 136 19 19 1 G136 14 2C 33935 SCREW 6ABX...

Страница 16: ...2 G136 400 GG136 400 34 2E 32054 JUMPER ELEMENT MEDIUM 4 G136 G136 480V 35 2N 30496UL ELEMENT 240V 2250W 4 G136 2N 45922UL ELEM 220V 4500W EU 2 G136 400 GG136 400 2N 48904UL ELEM HEATING 480V 2250W 4...

Страница 17: ...In Electric Griddles PARTS LIST G136 BUILT IN ELECTRIC GRIDDLE MODEL G196 HEATING ELEMENTS 208V 240V 380 415V and 480V IL1910 PL111 MODEL G196 HEATING ELEMENTS 208 240V and 480V GRIDDLE SHOWN INVERTE...

Страница 18: ...es 16 EXPLODED VIEW G196 BUILT IN ELECTRIC GRIDDLE MODEL G196 CABINET ELECTRICAL 208V 240V 380 415V and 480V ELECTRIC GRIDDLE G 196 CABINET COMPONENTS W ELLS IL1911 Rev B PL111 12 13 14 15 16 17 36 35...

Страница 19: ...5 16X132 G196 1 18 2E 37465 TERM BLOCK 3POLE 85AMP 1 208V 240V 480V 2E 40310 TERM BLOCK 4POLE 75AMP 380 415V 19 2C 41974 NUT 8 32 HEX 7 8 LONG ALU 2 20 2K 31040 BUSHING HEYCO 7 8 OD 2 21 1P 36178 TAP...

Страница 20: ...UL 800W 480V 2N 31495UL 4 ea NUT 10 32 HEX 2C 35313 NUT 1 4 20 HEX Ni 2C 31253 36 ea CLAMP ELEM CENTER DD 32037 10 ea CLAMP ELEM END G7 32038 8 ea CLAMP PERIMETER ELEMENT RIGHT G7 32026 CLAMP PERIMETE...

Страница 21: ...2K 31040 NUT HEX ALUMINUM 8 32 x 7 8 2C 41974 HANDLE 2R 38668 TRAY FRONT G7 Z12047 GREASE DRAWER COMPLETE ASSY WS 50279 GRIDDLE PLATE ASSEMBLY SPLASHGUARD LEFT G7 35783 SPLASHGUARD RIGHT G7 35782 SMOO...

Страница 22: ...27 CLAMP ELEM PERIM G7 32025 8 ea CLAMP THERMO BULB GRIDDLE G7 32028 12 ea ELEM PERIM 240V 1000W 2N 30507UL 480V 1000W 2N 31498UL ELEMENT 8ea 208V 2500W 2N 30513UL 240V 2500W 2N 30520UL 480V 2500W 2N...

Страница 23: ...ELLS SHROUD GREASE DRAWER WS 51989 HANDLE 2R 38668 TRAY FRONT G7 Z12047 GREASE DRAWER COMPLETE ASSY WS 50279 LIGHT SIGNAL AMBER 208 240V 2J 30516 480V M3 WL0113 4 reqd KNOB 2R 30259 4 reqd SHIELD THE...

Страница 24: ...2038 16 ea CLAMP PERIMETER ELEMENT RIGHT 2 ea G7 32026 CLAMP PERIMETER ELEMENT LEFT 2 ea G7 32027 CLAMP THERMO G7 32028 24 ea TUBE THERMO 2A 31971 8 ea CLIP INSULATION G7 33474 24 ea pk12 COVER GREASE...

Страница 25: ...2 reqd BUSHING HEYCO 7 8 2K 31040 4 reqd NUT HEX ALUMINUM 8 32 x 7 8 2C 41974 4 reqd THERMO CONTROL 2T 30257 8 reqd LIGHT SIGNAL AMBER 208 240V 2J 30516 480V M3 WL0113 8 reqd KNOB 2R 30259 8 reqd COV...

Страница 26: ...TOP ELECTRIC TEPPAN YAKI GRIDDLE MODEL JG246UL CABINET HEATING ELEMENTS 208 240V 480V GRIDDLE ref shown inverted 2N 41738UL 208 240V 2 ea 2N 304817UL 480V 2 ea I7 41830 2 ea G7 33474 6 ea G7 46178 2C...

Страница 27: ...6X 2 ea 2I Z12311 2 ea 2C 35736 WS 50131 2C 41974 2 ea 1P 36178 1 16 x2 x12 1O 32040 3 DD 45655 2P 2E 300355 1P 2C 31053 2T 46162 2E 30330 2C 33935 22 ea 2E 33192 2R 300356 1 5 0 200 25 0 30 0 350 4 0...

Страница 28: ...208 volt and 240 volt griddles are field convertible to single phase CONTROL KNOB CONFIGURATION For all models control knob p n 50259 is marked in degrees Fahrenheit from 200 F to 450 F When the ther...

Страница 29: ...Griddles are field convertible to single phase CONTROL KNOB CONFIGURATION For Teppan Griddles control knob p n 500536 is marked in degrees Fahrenheit from 150 F to 550 F When the thermostat is OFF th...

Страница 30: ...111 p n 2M 303340 OpManual Built In Electric Griddles 28 WIRING DIAGRAM...

Страница 31: ...29 WIRING DIAGRAM G196 111 p n 2M 303340 OpManual Built In Electric Griddles...

Страница 32: ...340 OpManual Built In Electric Griddles 30 WIRING DIAGRAM G236 L1 L2 L3 208 48 3 51 3 35 0 76 9 240 41 7 44 4 30 4 66 6 480 20 9 22 2 15 5 33 3 NORMAL AMPS PER LINE AMPS 3PH 16 VOLTS KW AMPS 1PH p n 2...

Страница 33: ...31 WIRING DIAGRAM G246 111 p n 2M 303340 OpManual Built In Electric Griddles...

Страница 34: ...111 p n 2M 303340 OpManual Built In Electric Griddles 32 WIRING DIAGRAM G606...

Страница 35: ...33 WIRING DIAGRAM JG246UL 111 p n 2M 303340 OpManual Built In Electric Griddles...

Страница 36: ...111 p n 2M 303340 OpManual Built In Electric Griddles 34 NOTES...

Страница 37: ...35 NOTES 111 p n 2M 303340 OpManual Built In Electric Griddles...

Страница 38: ...111 p n 2M 303340 OpManual Built In Electric Griddles 36 NOTES...

Страница 39: ...________________________________________________ ADDRESS ___________________________ STATE ______ ZIP__________ TELEPHONE NUMBER _____ _____ _________ EQUIPMENT MODEL NO _____________ EQUIP SERIAL NO...

Страница 40: ...WELLS MANUFACTURING 10 Sunnen Dr St Louis MO 63143 telephone 314 678 6314 fax 314 781 2714 www wellsbloomfield com...

Отзывы: