4
17. It is forbidden to use this product in case of thundering. Cut off the master supply of the
product and take out the power plug
18. Stop the service of the product with trouble on the electric circuit immediately, for it may
cause the fire by short-circuit or electric shock by trouble. Ask the qualified and licensed
professionals to make the repair.
II. Electrical parameters
Supply Voltage
Power
Output Voltage
Steam
generator
220V/
3KW
Lights
220V
12W
12V
III. Water supply
1. Connect the cold/hot water hose
(
red is hot water hose, blue is cold water hose
)
to water
supply, and make sure install a valve before connecting the cold/hot hose.
2. To prolong the service life of steam generator, we suggest install a wire mesh filter to the
cold/hot water hose.
IV. Electricity installation
: It is essential that the installation is carried out by a qualified
electrician.
1. Connect the master computer control box of the steam room to the wire connectors of all
functional electrical parts. Insert the wiring cords firmly, and keep them away from any
water pipe connector that may have water drips due to leakage. Identify the connection
symbols on the wiring cards before insertion, as the error connection may damage the
electrical parts in the steam room.
2. Reliably connect the earth wire of the steam room to the indoor electrical grounding unit
and make sure that it really works.
3. Connect the power supply.
(1)A fixed socket shall be taken for the power supply of the steam room, which should be
the bipolar switching socket for independent service (i.e., the null and live wires can be on or
off at the same time). No other electrical appliance can be connected to the same supply. The
power wire shall be the rubber-sheathed three-core wire, with the sectional area for each core
no less than 2mm2 (i.e., 3x2mm2). Fire-retardant wall bushing shall be used for the supply
crossing the wall to make it safe.
(2) This product is supplied with the special power wires and special plugs with leakage
protection. The user shall install the socket at the water-resistant place within the length
of the special power wire of the steam room, see installation and construction drawing.