Weller WHA3000V Скачать руководство пользователя страница 7

Page 7 of 14 

Selection of parameters by pressing button: 
 

 

TEMP

        (7) : Nozzle temperature in °C/°F 

        

(See Switching Temperature Conversation page 12) 

 

 

AIR

            (6) : Air flow rate in l/min 

 

 

TIME/  

 

 

      PREHEAT

 (5) : Switch 

ON-OFF 

the nozzle preheating (standby) at 200°C (392°F)  

         with 5 l/min airflow. 

 
After selection, the setting can be changed using the 

UP

 (2) or 

DOWN

 (3) Control Keys. Keeping the 

Control Key depressed, rapidly changes the values. 
 
The hot air and the nozzle vacuum can activated: 
Directly on the Control Panel: 

Hot air button 

START/STOP

 Control Key (10), 

Vacuum 

VAC

 Control Key (11) 

 
2-Position Foot Switch (21):   

Hot air-Position 1, Vacuum- Position 2 
(hot air and vacuum are only active in the Manual Mode, when 
the Foot Switch is depressed) 

 
Manual Control Console (21): 

Hot air 

"AIR" 

Control Key, Vacuum 

"VAC" 

Control Key 

 
 
When the hand-piece is placed in the AKT30 Safety Stand (20), the hot air is switched off by a Mirco 
Switch. If the nozzle pre-heating is active (PREHEAT ON), the device switches to the standby mode 
with reduced temperature and air flow  rate (200°C/392°F-5l/min). 

 
Note: Hot air is automatically disabled after 999 sec for safety reasons.

 

 
 

2.2 Automatic operating mode 

The Automatic operating mode has a 3-step temperature-time profile.  
The temperature-time profile can be expanded by connecting an optional WHP3000 bottom heater. 
When the WHP3000 is connected via the RS232 interface (14) the bottom heater is integrated into 
the time profile. 
 
The temperature profile is comprised of the following 3-steps: 
Pre-heat phase, system 

Step 1  

(ends with an audible tone) 

Pre-heat phase, component  Step 2  
Reflow process (soldering)  Step 3 
 
The soldering process is normally started with the hot gas nozzle raised. At the end of step 1 there 
is an audible tone, after this tone the nozzle should be placed over the component in the soldering 
position. At the end of Step 3, raise or remove the nozzle from the application. 
 
The following pre-settings must be made on the WHA 3000V controller to define a customer-specific 
temperature-time profile. 
 
 

Settings step 1 – step 3

 

Nozzle temperature   

50°C – 550°C (150°F / 999°F) 

Temperature, bottom heat 

50°C – 400°C (150°F / 750°F) (optional with WHP3000) 

Air flow rate   

 

5 l/min – 50 l/min 

Time for the program step   0 sec. – 999 sec. 

Содержание WHA3000V

Страница 1: ...Weller Tools GmbH Carl Benz Str 2 74354 Besigheim Germany Tel 49 0 7143 580 0 Fax 49 0 7143 580 108 WHA 3000V Hot Air Station Operating Instructions Version 2 3...

Страница 2: ...m function 10 2 6 Saving and loading temperature time profiles 10 3 External sensor 11 3 1 External sensor with measuring function MEASURE MODE 11 3 2 Teach in Mode procedure 11 3 3 External sensor wi...

Страница 3: ...ol key time specification auto mode preheating temperature 6 AIR Control key air volume 7 TEMP Control key hot air temperature 8 LED Indicator Vacuum 9 LED Indicator START STOP 10 START STOP Control k...

Страница 4: ...erface 15 PC Interface RS232 16 Connection for External Sensor Type K 17 Hand piece Connecting Hose 18 Connection for Compressed air 19 Connection for Nitrogen N2 400 600k Pa 20 Stand Switch Connectio...

Страница 5: ...ities for use of this repair station The hot air temperature at the hand piece can be adjusted within the range of 50 C 550 C 122 F 999 F Through an external compressed air supply or nitrogen N2 as an...

Страница 6: ...ing pressure is required The nitrogen connection 19 serves to generate hot air The compressed air connection 18 serves to generate vacuum by means of a compressed air converter If a separate nitrogen...

Страница 7: ...air flow rate 200 C 392 F 5l min Note Hot air is automatically disabled after 999 sec for safety reasons 2 2 Automatic operating mode The Automatic operating mode has a 3 step temperature time profil...

Страница 8: ...ce Nozzle temperature during the first step Depressed Twice Temperature of the bottom heater during the first step only with WHP3000 Repeat for Steps 1 3 Symbol for nozzle or bottom heater indicates w...

Страница 9: ...from the Locked center position It must remain in position directly over the Hot Plate to allow for the WHA 3000V to operate 2 5 Control of the vacuum function The nozzle vacuum are activated Directl...

Страница 10: ...riefly in the display 1 THERMOCOUPLE or THERMOCOUPLE MEASURE MODE CONTROL MODE Both operating modes only become active once the external sensor 16 has been connected 3 1 External Sensor with measuring...

Страница 11: ...y be operated using the START STOP 10 and VAC 11 Control Keys 5 Switching Temperature Conversion By pressing the Control Key Temp 7 when switching on the unit 4 you can toggle between the operating mo...

Страница 12: ...C LOCKED WHA locked lock function Unlock WHA TOOL STAND AKT30 Stand or WBH3000 Proximity Sensor Connect to socket 20 not connected 9 Accessories 0053119099 External sensor type K 0 5mm 0058754951 Exte...

Страница 13: ...2 sides heated Type ND 005 87 368 39 NQT Hot air nozzle 22 0 x 22 0 mm 005 87 368 41 NQT10 Hot air nozzle 14 8 x 14 8 mm 005 87 368 42 NQT25 Hot air nozzle 18 0 x 18 0 mm 005 87 368 43 NQT Hot air noz...

Страница 14: ...etting hot air temperature manual mode Setting hot air temperature and bottom heater for step 1 3 auto mode Setting flow rate manual mode setting flow rate for step 1 3 auto mode Time setting for step...

Отзывы: