Page 10 of 14
PROGRAM 1
E X I T L O A D S A V E
The program memories 1 - 10 can be selected using the
UP/DOWN
Control Keys (2)/(3).
The preferred program can be selected by pressing the
LOAD
Control Key (6).
The indication on the display changes to the automatic mode and displays the selected parameters.
If a temperature-profile has been prepared, it can be saved in the selected program memory by
pressing the
SAVE
Control Key (5).
The menu can be exited without saving any changes using the
EXIT
Control Key (7).
3. External Sensor
When using an external sensor (Thermocouple Type K), two different operating modes are
available. By pressing the Control Key "
TIME
" / "
PREHEAT
" (5) when switching on the unit (4), you
can toggle between the operating modes "
MEASURE MODE
" and "
CONTROL MODE
". The
following appears briefly in the display (1):
THERMOCOUPLE
or
THERMOCOUPLE
MEASURE
MODE
CONTROL
MODE
Both operating modes only become active once the external sensor (16) has been connected.
3.1 External Sensor with measuring function "MEASURE MODE" (factory setting)
In this operating mode, the external sensor only has a measuring function. The temperature of the
external sensor is shown in the display (1). The Hot Air Tool temperature control regulates the
setpoint value for the nozzle temperature.
External
sensor
active
in
"MEASURE
MODE"
3.2 Teach In Mode procedure
During the sequence of an automatic temperature-time profile, it is possible to continue switching the
process stages 1-3 manually by pressing the Control Key "
TIME
" / "
PREHEAT
" (5). If the external
sensor is suitably positioned on the assembly or component, its temperature can be monitored
during the entire process sequence and can be continued to be switched when the desired specified
UP
PRESS AT
THE SAME
TIME
DOWN
TEMP AIR
PREHEAT
250 °C
25 l
OFF