PROGRAM 1 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E X I  T     L  O A D     S A V E

 

 
 

 

 
The program memories 1 - 10 can be selected using the 

UP/DOWN

 Control Keys (2)/(3). 

 
The preferred program can be selected by pressing the 

LOAD

 Control Key (6). 

The indication on the display changes to the automatic mode and displays the selected parameters. 
 
If a temperature-profile has been prepared, it can be saved in the selected program memory by 
pressing the 

SAVE

 Control Key (5). 

 
The menu can be exited without saving any changes using the 

EXIT

 Control Key (7). 

 
 

3. External Sensor 

When using an external sensor (Thermocouple Type K), two different operating modes are 
available. By pressing the Control Key "

TIME

" / "

PREHEAT

" (5) when switching on the unit (4), you 

can toggle between the operating modes "

MEASURE MODE

" and "

CONTROL MODE

". The 

following appears briefly in the display (1): 
 
 
 

THERMOCOUPLE 

  or 

  THERMOCOUPLE 

 

MEASURE 

MODE 

     CONTROL 

MODE 

 
Both operating modes only become active once the external sensor (16) has been connected. 
 
 

3.1 External Sensor with measuring function "MEASURE MODE"   (factory setting)

 

In this operating mode, the external sensor only has a measuring function. The temperature of the 
external sensor is shown in the display (1). The Hot Air Tool temperature control regulates the 
setpoint value for the nozzle temperature. 
 
 
      External 

sensor 

active 

in 

"MEASURE 

MODE" 

 

 
 
 
 
 
 

3.2 Teach In Mode procedure 

During the sequence of an automatic temperature-time profile, it is possible to continue switching the 
process stages 1-3 manually by pressing the Control Key "

TIME

" / "

PREHEAT

" (5). If the external 

sensor is suitably positioned on the assembly or component, its temperature can be monitored 
during the entire process sequence and can be continued to be switched when the desired specified 

 
 

           
UP 

PRESS AT          
THE SAME 
TIME

 

 

DOWN 

 

TEMP AIR 

PREHEAT

 

 

 

 

 

250 °C 

25 l 

OFF 

 

 

 

 

Содержание WHA 3000VS

Страница 1: ...Weller Tools GmbH Carl Benz Str 2 74354 Besigheim Germany Tel 49 0 7143 580 0 Fax 49 0 7143 580 108 WHA 3000V Hot Air Station Operating Instructions Version 2 3...

Страница 2: ...m function 10 2 6 Saving and loading temperature time profiles 10 3 External sensor 11 3 1 External sensor with measuring function MEASURE MODE 11 3 2 Teach in Mode procedure 11 3 3 External sensor wi...

Страница 3: ...ol key time specification auto mode preheating temperature 6 AIR Control key air volume 7 TEMP Control key hot air temperature 8 LED Indicator Vacuum 9 LED Indicator START STOP 10 START STOP Control k...

Страница 4: ...erface 15 PC Interface RS232 16 Connection for External Sensor Type K 17 Hand piece Connecting Hose 18 Connection for Compressed air 19 Connection for Nitrogen N2 400 600k Pa 20 Stand Switch Connectio...

Страница 5: ...ities for use of this repair station The hot air temperature at the hand piece can be adjusted within the range of 50 C 550 C 122 F 999 F Through an external compressed air supply or nitrogen N2 as an...

Страница 6: ...ing pressure is required The nitrogen connection 19 serves to generate hot air The compressed air connection 18 serves to generate vacuum by means of a compressed air converter If a separate nitrogen...

Страница 7: ...air flow rate 200 C 392 F 5l min Note Hot air is automatically disabled after 999 sec for safety reasons 2 2 Automatic operating mode The Automatic operating mode has a 3 step temperature time profil...

Страница 8: ...ce Nozzle temperature during the first step Depressed Twice Temperature of the bottom heater during the first step only with WHP3000 Repeat for Steps 1 3 Symbol for nozzle or bottom heater indicates w...

Страница 9: ...from the Locked center position It must remain in position directly over the Hot Plate to allow for the WHA 3000V to operate 2 5 Control of the vacuum function The nozzle vacuum are activated Directl...

Страница 10: ...riefly in the display 1 THERMOCOUPLE or THERMOCOUPLE MEASURE MODE CONTROL MODE Both operating modes only become active once the external sensor 16 has been connected 3 1 External Sensor with measuring...

Страница 11: ...y be operated using the START STOP 10 and VAC 11 Control Keys 5 Switching Temperature Conversion By pressing the Control Key Temp 7 when switching on the unit 4 you can toggle between the operating mo...

Страница 12: ...C LOCKED WHA locked lock function Unlock WHA TOOL STAND AKT30 Stand or WBH3000 Proximity Sensor Connect to socket 20 not connected 9 Accessories 0053119099 External sensor type K 0 5mm 0058754951 Exte...

Страница 13: ...2 sides heated Type ND 005 87 368 39 NQT Hot air nozzle 22 0 x 22 0 mm 005 87 368 41 NQT10 Hot air nozzle 14 8 x 14 8 mm 005 87 368 42 NQT25 Hot air nozzle 18 0 x 18 0 mm 005 87 368 43 NQT Hot air noz...

Страница 14: ...etting hot air temperature manual mode Setting hot air temperature and bottom heater for step 1 3 auto mode Setting flow rate manual mode setting flow rate for step 1 3 auto mode Time setting for step...

Отзывы: