background image

Weller Tools GmbH 

Carl-Benz-Str. 2, 74354 Besigheim, Germany 

Tel: +49 (0) 7143 580- 0, Fax: +49 (0) 7143 580- 108 

 

 

 

 
 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

WHA 3000V Hot Air Station 

 

Operating Instructions 

 

Version 2.3 

 

 
 
 

 

Содержание WHA 3000VS

Страница 1: ...Weller Tools GmbH Carl Benz Str 2 74354 Besigheim Germany Tel 49 0 7143 580 0 Fax 49 0 7143 580 108 WHA 3000V Hot Air Station Operating Instructions Version 2 3...

Страница 2: ...m function 10 2 6 Saving and loading temperature time profiles 10 3 External sensor 11 3 1 External sensor with measuring function MEASURE MODE 11 3 2 Teach in Mode procedure 11 3 3 External sensor wi...

Страница 3: ...ol key time specification auto mode preheating temperature 6 AIR Control key air volume 7 TEMP Control key hot air temperature 8 LED Indicator Vacuum 9 LED Indicator START STOP 10 START STOP Control k...

Страница 4: ...erface 15 PC Interface RS232 16 Connection for External Sensor Type K 17 Hand piece Connecting Hose 18 Connection for Compressed air 19 Connection for Nitrogen N2 400 600k Pa 20 Stand Switch Connectio...

Страница 5: ...ities for use of this repair station The hot air temperature at the hand piece can be adjusted within the range of 50 C 550 C 122 F 999 F Through an external compressed air supply or nitrogen N2 as an...

Страница 6: ...ing pressure is required The nitrogen connection 19 serves to generate hot air The compressed air connection 18 serves to generate vacuum by means of a compressed air converter If a separate nitrogen...

Страница 7: ...air flow rate 200 C 392 F 5l min Note Hot air is automatically disabled after 999 sec for safety reasons 2 2 Automatic operating mode The Automatic operating mode has a 3 step temperature time profil...

Страница 8: ...ce Nozzle temperature during the first step Depressed Twice Temperature of the bottom heater during the first step only with WHP3000 Repeat for Steps 1 3 Symbol for nozzle or bottom heater indicates w...

Страница 9: ...from the Locked center position It must remain in position directly over the Hot Plate to allow for the WHA 3000V to operate 2 5 Control of the vacuum function The nozzle vacuum are activated Directl...

Страница 10: ...riefly in the display 1 THERMOCOUPLE or THERMOCOUPLE MEASURE MODE CONTROL MODE Both operating modes only become active once the external sensor 16 has been connected 3 1 External Sensor with measuring...

Страница 11: ...y be operated using the START STOP 10 and VAC 11 Control Keys 5 Switching Temperature Conversion By pressing the Control Key Temp 7 when switching on the unit 4 you can toggle between the operating mo...

Страница 12: ...C LOCKED WHA locked lock function Unlock WHA TOOL STAND AKT30 Stand or WBH3000 Proximity Sensor Connect to socket 20 not connected 9 Accessories 0053119099 External sensor type K 0 5mm 0058754951 Exte...

Страница 13: ...2 sides heated Type ND 005 87 368 39 NQT Hot air nozzle 22 0 x 22 0 mm 005 87 368 41 NQT10 Hot air nozzle 14 8 x 14 8 mm 005 87 368 42 NQT25 Hot air nozzle 18 0 x 18 0 mm 005 87 368 43 NQT Hot air noz...

Страница 14: ...etting hot air temperature manual mode Setting hot air temperature and bottom heater for step 1 3 auto mode Setting flow rate manual mode setting flow rate for step 1 3 auto mode Time setting for step...