background image

19

Read these instructions and the safety 
guidelines carefully before starting up the unit 
and starting work.

)DLOXUHWRREVHUYHWKHVDIHW\UHJXODWLRQVUHVXOWVLQDULVNWR

life and limb.

Keep these instructions in a place that is accessible to all 
users. Please adhere to the operating instructions of the 
connected devices.

Safety information

7KLVDSSOLDQFHFDQEHXVHGE\FKLOG

-

UHQDJHGIURP\HDUVDQGDERYHDQG
SHUVRQVZLWKUHGXFHGSK\VLFDOVHQVRU\

or mental capabilities or lack of experi-

HQFHDQGNQRZOHGJHLIWKH\KDYHEHHQ

given supervision or instruction concer-

QLQJXVHRIWKHDSSOLDQFHLQDVDIHZD\

and understand the hazards involved. 

&KLOGUHQVKDOOQRWSOD\ZLWKWKHDSSOL

-

ance.

Cleaning and user maintenance shall 

QRWEHPDGHE\FKLOGUHQZLWKRXWVXSHU

-

vision.

Keep other persons well away from your workplace. 

The work area is out of bounds for children and unauthorised 
persons. Never allow other persons to touch the soldering 
tool or cable. 

 

WARNING

  

Electrical shock

Connecting the control unit incorrectly poses a risk of 
injury due to electric shock and can damage the device. 

• 

&DUHIXOO\UHDGWKHDWWDFKHGVDIHW\LQIRUPDWLRQWKHVDIHW\
LQIRUPDWLRQDFFRPSDQ\LQJWKHVHRSHUDWLQJLQVWUXFWLRQVDV
ZHOODVWKHRSHUDWLQJLQVWUXFWLRQVIRU\RXUFRQWUROXQLWEHIRUH

putting the control unit into operation and observe the 

VDIHW\SUHFDXWLRQVVSHFL¿HGWKHUHLQ

• 

2QO\FRQQHFW:(//(5WRROV

If the device is faulty, active electrical conductors may be 
bare or the PE conductor may not be functional.

• 

5HSDLUVPXVWDOZD\VEHUHIHUUHGWRD:HOOHUWUDLQHG

specialist.

• 

,IWKHHOHFWULFDOWRROµVSRZHUVXSSO\FRUGLVGDPDJHGLWPXVW
EHUHSODFHGZLWKDVSHFLDOO\SUHIDEULFDWHGSRZHUVXSSO\

cord available through the customer service organisation.

Protect yourself against electric shocks.

 The handles on 

soldering tools with an antistatic design are conductive.

• 

Avoid touching earthed objects such as pipes, heaters, 
cookers and refrigerators.

• 

Do not use the soldering tool in a damp or wet environment.

• 

1HYHUZRUNRQYROWDJHFDUU\LQJSDUWV

 

WARNING

  

Risk of burns

Risk of burns from the soldering tool while the control 
unit is operating. Tools may still be hot long after they 
have been switched off.

(S^H`ZWSHJL[OLZVSKLYPUN[VVSPU[OLZHML[`YLZ[^OPSLUV[
PU\ZL4HRLZ\YL[OLZHML[`OVSKLYPZZ[HISL

6US`YLWSHJLZVSKLY[PWZ^OLUJVSK

Risk of burning through liquid solder. Protect yourself 
against solder splashes.

>LHYHWWYVWYPH[LWYV[LJ[P]LJSV[OPUN[VWYV[LJ[`V\YZLSM
HNHPUZ[I\YUZ7YV[LJ[`V\YL`LZI`^LHYPUNL`L
WYV[LJ[PVU

>OLU^VYRPUN^P[OHKOLZP]LZZWLJPHSH[[LU[PVUT\Z[IL
WHPK[V[OL^HYUPUNPUMVYTH[PVUWYV]PKLKI`[OLHKOLZP]L
THU\MHJ[\YLY

 

WARNING

  

Fire hazard

Covering the soldering iron or the safety holder poses 

D¿UHKD]DUG$OZD\VNHHSREMHFWVZHOODZD\IURPWKH

soldering iron and safety holder.

• 

$OZD\VNHHSREMHFWVZHOODZD\IURPWKHVROGHULQJLURQ
DQGVDIHW\KROGHU

• 

.HHSDOOFRPEXVWLEOHREMHFWVOLTXLGVRUJDVHVZHOODZD\

from the hot soldering tool.

EN

ENGLISH

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание 037103326911

Страница 1: ...gsanvisning FI Alkuper isten ohjeiden k nn s GR TR 2ULMLQDO L OHWPH WDOLPDW oHYLULVL CZ 3 HNODG S YRGQtKR QiYRGX N SRX tYiQt PL 7 XPDF HQLHP LQVWUXNFML RU JLQDOQHM HU UHGHWL KDV QiODWL XWDVtWiV IRUGtW...

Страница 2: ...2 MANUAL FAQ i VIDEO www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 3: ...3 1 2 50 mm WT 2M www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 4: ...20099 WP 120 SET T0052919499 WSP 150 SET T0052918999 3 w w w weller tool s c o m 2 1 1 1 2 2 230 V WTP 90 SET T0052922399 W T 110 120 V WMRT SET T0051317399N WMRP SET T0052919099N www GlobalTestSupply...

Страница 5: ...5 4 5 C F OFF ON 1 2 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 6: ...6 6 1 1 2 2 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 7: ...7 7 8 ON OFF 1 ON OFF ON OFF 2 OFF ON C F C F www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 8: ...8 9 1 99 min 100 300 C 200 600 F 1 999 min MENU 2 1 3 sec www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 9: ...9 1 99 C 1 180 F 1 999 40 40 C 72 72 F C F EXIT ON OFF FE rob 0 100 1 5 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 10: ...UH ES 7HPSHUDWXUD VWDQGE FR 7HPSpUDWXUH 6WDQG E IT 7HPSHUDWXUD VWDQGE PT 7HPSHUDWXUD 6WDQGE NL 6WDQGE WHPSHUDWXXU SV Vilotemperatur DK 6WDQGE WHPSHUDWXU FI Valmiusl mp tila GR TR Bekleme Sicakligi CZ...

Страница 11: ...WD SL Stalna temperatura EE P sitemperatuur LV 1RWHLNW WHPSHUDW UD LT LNVXRWRML WHPSHUDW UD BG RO 7HPSHUDWXUD HR Fiksna temperatura RU CN KO JP DE Verriegelungsfunktion EN lock function ES funci n de...

Страница 12: ...otuitgang SV Zero Smog Robotutg ng DK Zero Smog Robotudgang FI Zero Smog Robottil ht GR Zero Smog TR Zero Smog 5RERW o N CZ Zero Smog 9 VWXS URERWX PL Zero Smog M FLH XU G HQ URERW RZDQ FK HU Zero Smo...

Страница 13: ...150 W Tool combination not possible ES Funci n ilimitada Reducci n de potencia a 150 W Combinaci n de herramientas no permitida FR Fonction sans restriction Diminution de la puissance 150 W Combinaiso...

Страница 14: ...PELQiFLy QHP OHKHW s ges SK 1HREPHG HQi IXQNFLD 5HGXNFLD Y NRQX QD RPELQiFLD QiVWURMRY QLH MH PR Qi SL Neomejeno delovanje PDQM DQMH PR L QD RPELQDFLMD RURGLM QL PRJR D EE Piiranguteta talitlus V imsu...

Страница 15: ...tive electrical conductors may be bare or the PE conductor may not be functional 5HSDLUV PXVW DOZD V EH UHIHUUHG WR D HOOHU WUDLQHG specialist I WKH HOHFWULFDO WRRO V SRZHU VXSSO FRUG LV GDPDJHG LW PX...

Страница 16: ...LQMXU Secure the tool 8VH FODPSLQJ WXUHV WR KROG WKH workpiece Use a solder fume extraction unit If appliances for connecting solder fume extraction units are available ensure WKDW WKH DUH FRQQHFWHG D...

Страница 17: ...mpile technical documentation Weller Tools GmbH DUO HQ 6WUD H HVLJKHLP HUPDQ Technical Data Soldering station WT 2M Dimensions L x W x H mm Inch 150 x 130 x 101 5 91 x 5 12 x 3 98 Fuse 230 V A 120 V A...

Страница 18: ...ervice du bloc de contr le et respectez les mesures de s curit TXL VRQW LQGLTXpHV Raccordez uniquement les outils de WELLER Un appareil d fectueux peut pr senter des conducteurs actifs mis nu ou le co...

Страница 19: ...ement et toutes les con GLWLRQV UHPSOLHV D Q GH SRXYRLU JDUDQWLU OH IRQFWLRQQHPHQW impeccable de l outil Servez vous d un outil adapt Utilisez uniquement des accessoires ou outils auxiliaires indiqu s...

Страница 20: ...clamations pour vices de fabrication expirent 12 mois apr s la livraison Ceci ne s applique pas aux droits de recours de l acqu reur d apr s le 478 479 du code civil allemand La garantie que nous acco...

Отзывы: