welldana D66-112015 Скачать руководство пользователя страница 4

1.4 

Specifications 

 

 

Type no. 

Power 

(kW) 

Current  

(A)  

400V 50Hz 

(1ph.230V50Hz) 

Max. 

airflow 

(m³/hour) 

Max. 

Vacuum / 

compression 

(mbar) 

Noise 

level 

(dB) 

Weight 

(Kg) 

KB-129 

KB-129L 

KB-129 

0.18 
0.18 

0.2 

0.52 (1.45) 

0.52 

0.69 (1.5) 

48 
48 
48 

50 / 60 
50 / 60 
70 / 70 

53 
50 
53 

6.5 
6.5 
6.5 

KB-229 

KB-229L 

0.4 
0.4 

1.2 (2.8) 
1.2 (2.8) 

84 
84 

110 / 130 
110 / 130 

58 
58 

11 

11.5 

KB-329 

KB-329L 

KB-329 
KB-339 

0.75 
0.75 

0.9 
1.3 

1.9 (6.5) 
1.9 (6.5) 

2.4 
2.7 

144 
144 
144 
144 

140 / 140 
140 / 140 
165 / 180 
175 / 200 

63 
63 
63 
63 

14.5 

15 

15.5 

16 

KB-429 
KB-429 

KB-429L 

KB-429 
KB-429 

KB-429L 

KB-429 

0.9 
1.3 
1.3 
1.5 

1.75 
1.75 

2.2 

2.4 (8.0) 
3.3 (9.5) 
3.3 (9.5) 

(12.3) 

3.9 
3.9 
4.5 

216 
216 
216 
216 
216 
216 
216 

130 / 130 
180 / 180 
180 / 180 
210 / 220 
210 / 220 
210 / 220 
220 / 270 

70 
70 
70 
70 
70 
70 
70 

20.5 

22 

22.5 
22.5 

23 

23.5 

26 

KB-529 

KB-529L 

KB-629 

KB-629L 

KB-639 

2.2 
2.2 
3.4 
3.4 

5.6 (16.7) 

5.6 

7.2 (28) 

7.2 
8.2 

312 
312 
312 
312 
312 

230 / 230 
230 / 230 
260 / 280 
260 / 280 
270 / 330 

72 
72 
72 
72 
72 

32 
33 
35 
36 
38 

KB-729 
KB-829 

5.5 
7.5 

12 

15.6 

552 
552 

270 / 300 
300 / 400 

74 
74 

78 
82 

KB-919  
KB-929 
KB-939 

13 
20 

21.4 

30 
44 

1134 
1134 
1134 

200 / 200 
300 / 300 
350 / 450 

76 
76 
76 

100 
112 
159 

KB-2308 

0.75 

2.0 

90 

200 / 240 

60 

17 

KB-3319 
KB-3326 

1.75 

2.2 

3.9 
4.5 

156 
156 

275 / 320 
280 / 375 

66 
66 

25 
28 

KB-4337 
KB-4346 

3.4 
4.0 

7.2 
8.2 

222 
222 

345 / 410 
355 / 495 

74 
74 

43 
45 

KB-6346 
KB-6355 
KB-6375 

4.0 
5.5 
7.5 

8.2 

12 

15.6 

312 
312 
312 

360 / 380 
410 / 515 
420 / 580 

75 
75 
75 

55 
72 
81 

KB-6455 
KB-6475 

5.5 
7.5 

12 

15.6 

468 
468 

200 / 220 
240 / 270 

75 
75 

70 
81 

KB-8310 
KB-8315 
KB-8320 

7.5 

11 
16 

15.6 

27 

37.5 

576 
576 
576 

320 / 320 
430 / 600 
450 / 700 

76 
76 
76 

112 
142 
160 

KB-8410 
KB-8415 

7.5 

11 

15.6 

27 

990 
990 

150 / 150 
260 / 260 

76 
76 

110 
140 

 
 

Содержание D66-112015

Страница 1: ...Operation Instructions Compressor Vacuum pumps Models D66 112015 Welldana A S All rights reserved Edition 11 2014...

Страница 2: ...ation 2 1 Transport and storage 6 2 2 Installation 6 2 3 Electrical connection 10 2 4 Commissioning 11 1 Maintenance 3 1 Cleaning 13 3 2 Lubrication 14 3 3 Parts list drawing for single stage blowers...

Страница 3: ...technical data Blowers with limited performance curves in the high pressure range should be fitted with the relative pressure relief valves in order to avoid an overload of the motor Pressure relief...

Страница 4: ...0 70 70 20 5 22 22 5 22 5 23 23 5 26 KB 529 KB 529L KB 629 KB 629L KB 639 2 2 2 2 3 4 3 4 4 5 6 16 7 5 6 7 2 28 7 2 8 2 312 312 312 312 312 230 230 230 230 260 280 260 280 270 330 72 72 72 72 72 32 33...

Страница 5: ...achine commissioning under favourable circumstances storage in a dry dust free and vibration free room Under unfavourable circumstances this period is considerably reduced 2 2 Installation A Kleeblowe...

Страница 6: ...ntly Do not mount the piping to the blower flange or casing to avoid damaging the blower I The sectional area curve of the pipe diameter should be no less than 60 of the sectional area curve of the bl...

Страница 7: ...uild up heat around the outlet of the blower To lead away the heat an iron pipe at minimum 1 meter is thus needed to be connected to the outlet N On the discharge side the cover impeller and silencer...

Страница 8: ...connection Pressure increases Model A Pressure 90 of Model A Model B Air flow Model A Model B Parallel connection airflow increases Model A Pressure Model A or Model B Air flow Model A Model B Model...

Страница 9: ...s are used as power supply high frequency current and voltage harmonics in the motor cables can cause electromagnetic interference Therefore shielded motor cables are recommended D Exceeding the opera...

Страница 10: ...properly assembled aligned and connected to piping or hoses as appropriate D The elevation of the installation location is taken into account when adjusting the pressure control valves E The direction...

Страница 11: ...hazard for eyes and skins When air is sucked in from the atmosphere the inlet must be covered with protective devices i e gratings in order to prevent foreign elements including parts of the body and...

Страница 12: ...NG Before any work is performed on the blower or equipment especially covers over moving parts are removed the blower should be properly disconnected from the power supply or frequency drive Wait unti...

Страница 13: ...hould have the old grease removed and be recharged with new grease About 50 of the free space in the rolling contact bearings and about 65 of the adjacent grease spaces should be filled with grease B...

Страница 14: ...ng 06 Motor Housing 11 1 Cable Gland 15 1 Silencer Gasket 02 3 Disc 06 1 Sponge Filler 11 2 Rubber Gasket Under 16 Inlet Outlet 02 1E Bearing Socket 06 1E Bracket 11 3 Terminal Board 16 1 Inlet Outlet...

Страница 15: ...Cover 11 3E Rubber Ring 17 Middle Cover 02 3 Disc 07 1 Rear Bearing 12 Terminal Box Cover 18 Middle Housing 02 1E Bearing Socket 07 2 Wave Washer 12 1 Rubber Gasket Upper 18 1 Impeller Fixing Set 03 C...

Страница 16: ...9 KB 529L KB 629 KB 629L Kb 639 6206ZZCM 6304ZZCM KB 729 KB 829 6207ZC3 6207ZZCM KB 919 KB 929 KB 939 6308ZC3 6209ZZCM KB 2308 KB 2309 KB 2315 6203ZZCM 6202ZZCM KB 3319 KB 3326 6204ZC3 6204ZZCM KB 433...

Страница 17: ...again after motor is switched on power consumption is too high Short circuit in the winding Arrange for winding to be inspected Motor overloaded Reduce operating pressure clean filter silencer connec...

Страница 18: ...3 7 EC Declaration of Conformity...