SMP180 IRD Quick Installation Guide 

V1.1-N 

 

 

 

 

 

 

SMP180 Integrated Digital Receiver 

 

Quick Installation Guide

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание SMP180

Страница 1: ...SMP180 IRD Quick Installation Guide V1 1 N SMP180 Integrated Digital Receiver Quick Installation Guide...

Страница 2: ...ake sure the rack has been correctly grounded before switching on the device To mount the SMP180 unit to a 19 42U rack please perform the following steps 1 Make sure the mounted rack surface is stable...

Страница 3: ...ces are required grounded Turn on the devices only after the wiring connection is completed Otherwise the device may be damaged Follow the below connection diagram to set up cable connection PIC 1 2 1...

Страница 4: ...t and output simultaneously User only needs to connect one RJ45 cable to the TS IP port of the device 1 3 Power Connection Connect this equipment only to the power sources that are identified on the e...

Страница 5: ...following PIC 2 1 1 The initialization takes about 30 seconds to complete If the unit fails to initialize and hangs at the booting screen swtiching off the device and then powering up again may help I...

Страница 6: ...menu Step 3 To change parameter settings press arrow RIGHT and arrow LEFT button to move the cursor in which change must be made Press arrow UP button and arrow DOWN to input select an appropriate se...

Страница 7: ...stallation NMS operation is highly recommended In this installation guide operation instruction is based on NMS style For front panel operation instruction please refer to product user manual z Instal...

Страница 8: ...user wants to directly log on the NMS without inputting the user name and password Select Login to log on the device Possible reasons for unsuccessful log on IP address network mask gateway doesn t m...

Страница 9: ...rea by its IP address 3 Parameter setting and configuration area The parameters of the equipment are shown and configured here by selecting different tabs This is the main operation area of the NMS It...

Страница 10: ...selecting this item the NMS displays the current system operation data status of the equipment User can swtich between tab under the Status to check the current working status of the equipment PIC 2 3...

Страница 11: ...te Input the symbol rate of the transponder The unit is KS s Polarization Select the voltage provided to LNB 13V for vertical or 18V for Horizontal LOLow frequency The low frequency of LNB The unit is...

Страница 12: ...5 Key Parameters Description Type The status of each ASI port is Input or Output not editable Constant Rate Mbit Set constant bit rate for ASI output Note For the input parameters it is all automatic...

Страница 13: ...iving multicast unicast IP stream PIC 6 3 7 Key Parameters Description ChannelSelect In this ChannelSelect user can select a channel to configure its parameters Enable On enable the IP receiving funct...

Страница 14: ...n RowPortMatching FEC Parameter The bigger values it is the stronger capabilities it has to correct the data mistakes But the FECL and FECD should be less than 100 After setting all the parameters you...

Страница 15: ...o 76Mbit input TS 10 5MHz support up to 84Mbit input TS 11 5MHz support up to 92Mbit input TS 13MHz support up to 104Mbit input TS The correct TSClock need to be selected according the inserted CAM pr...

Страница 16: ...ts transmitting parameters Enable On enable the IP transmission function Off disable the IP transmission function Note this parameter setting applies to all channels Channel configuration EnableChanne...

Страница 17: ...hich is connected with input stream and then click the mouse right button and select Scan TS menu All the input stream of that port will be scanned and displayed PIC 2 3 11 Please select the port whic...

Страница 18: ...configuration is done From the mainboard item user can find the current system operation data status of the equipment User can swtich between tab under the Status to check the current working status o...

Страница 19: ...be not updated in time You need check the network connection and restart the NMS After completing the configuration and making sure it s done from checking the status of mainboard and sub module user...