background image

INSTRUCTION MANUAL

Royale 400

Rev. June 17

Содержание Royale 400

Страница 1: ...INSTRUCTION MANUAL Royale 400 Rev June 17 ...

Страница 2: ...he steps within The old adage of if all else fails read the instruction manual needs to be applied from the onset Well Tempered Lab cannot be held responsible for consequences resulting from the failure to comprehend these instructions If in doubt always consult with your dealer Well Tempered Lab s policy is the continuous improvements of its products We therefore reserve the right of departure fr...

Страница 3: ...eflon bearing is correctly orientated to the motor pulley See Fig 1 If necessary consult your dealer Fill the bearing with synthetic oil supplied to a level of approx 5mm 1 4 above the bottom Teflon bearing this is not critical Do not overfill Over filling the bearing will cause the oil to overflow the bearing housing when the platter spindle is lowered into the bearing housing Gently lower platte...

Страница 4: ...y take care the other end clears the centre spindle and rotate the platter the belt will track around the platter See Fig 4 Well Tempered Lab belts if dropped are easily misplaced we give you two but suggest you place the belt on something dark to make it easily seen Fig 4 4 ...

Страница 5: ...ary strobe equipment by rotating the knob to adjust to the required speed The Royale 400 also features a 33 RPM to 45 RPM switch function which is operated when the belt is on the 33 position on the stepped motor pulley Note Some early versions of Royale 400 were 120 240VAC Current models are 12VDC 12VDC Fig 6 120 240VAC Fig 7 5 ...

Страница 6: ...rits or white gas We suggest you first try cleaning fluid with caution and or the underside of the plinth The Well Tempered Lab can bear no responsibility for damage caused by cleaning fluid 3 Well Tempered Lab belts are easily lost We recommend placing or hanging on a dark background when not on the turntable 4 For cartridges without threaded fixing holes we find it most convenient to attach the ...

Страница 7: ...motor clear of the mounting cover plate 6 If the platter rotates abnormally please refer to page 3 Installing the Platter to centre the spindle 7 Important For optimum performance Well Tempered turntables require to operate on a flat and level surface 8 When moving or shipping the turntable we recommend the removal of the platter from the bearing assembly Care must be taken as there will be a smal...

Страница 8: ...ed Lab unequivocally reiterate that it should not be moved Heavy handed mounting of the cartridge may result in moving the head shell In which case place the above guide with centre line parallel to tone arm tube and align head shell to 19 angle It will be necessary to gently but firmly retighten the small screw fixing the head shell to the tonearm Do not over tighten this screw 1 2 3 19 8 ...

Страница 9: ...ely decoupled from plinth Voltage The Royale 400 is shipped with the voltage for your country Drive 004mm Polyester thread Tonearm Arm tube 16 Aluminium arm tube with internal damping Symmetrex configuration Azimuth Adjustment Stainless steel collar Suspension Polyester thread providing anti skate Damping Silicone fluid 100 000 cSt viscosity Dimensions H x W x D 250 x 635 x 555 mm 470 x 845 x 765 ...

Страница 10: ...Under This Warranty The product should be returned to the dealer or nearest Well Tempered distributor complete with warranty card and confirmed date of purchase Note special care is required with the fluids and the Well Tempered Lab and its agents can bear no responsibility for spillage or damage caused by incorrect handling and packaging of the fluids The European Waste Electrical and Electronic ...

Отзывы: