Installing the Relief Valve
11.
Either wrap the threads of the relief valve with PTFE tape or apply pipe dope to the threads.
12.
Using a wrench, install the relief valve to the correct port on the instrument it will be relieving.
13.
Installation is complete, and the relief valve is now operational.
2.3 Installing and Setting the Relief: RV-2CP
If setting and installing an RV-1, RV-2, or RV-3, see
Section 2.2, Setting and Installing the Relief: RV-1, RV-2, and RV-3
.
Installing the RV-2CP
Prior to being set, the RV-2CP must be installed to the cylinder it will be relieving.
1.
Install the seat of the RV-2CP to the cylinder the RV-2CP will be relieving (
). The O-ring side of the seat must face
away from the RV-2CP.
2.
Either wrap the threads of the RV-2CP with PTFE tape or apply pipe dope to the threads.
3.
Install the RV-2CP on top of the seat.
4.
Using a torque wrench, tighten the RV-2CP to 30 ft•lb. The RV-2CP may now be set.
Setting the RV-2CP
To accurately set the relief, a safe gas source, regulator, and pressure gauge are needed.
5.
Connect the regulator to a safe gas source.
6.
Using a hex key, screw the spring adjuster of the RV-2CP clockwise to fully close the RV-2CP.
7.
Connect from the regulator to the cylinder end cap to which the RV-2CP is installed.
8.
Set the regulator to the desired pressure, and then apply auxiliary gas through the regulator to the RV-2CP.
9.
Using a hex key, screw the spring adjuster of the RV-2CP counterclockwise until pressure starts to relieve. A hissing
sound will be audible.
10.
Screw the spring adjuster of the RV-2CP clockwise until the hissing sound stops and the RV-2CP obtains a positive
shutoff.
Testing the RV-2CP
11.
Set the regulator to a pressure slightly below the RV-2CP set point, and then slowly increase the pressure of the
regulator until it is slightly higher than the RV-2CP set point. A hissing sound should be audible.
12.
Slowly decrease the pressure of the regulator until it is slightly below the RV-2CP set point. The hissing sound should
stop as the RV-2CP reseats.
13.
If the RV-2CP does not begin to relieve pressure or does not reseat, it may be necessary to repeat steps 8–10 to reset
the RV-2CP.
14.
Disconnect the regulator from the cylinder end cap.
15.
The RV-2CP is now operational.