40
WELGER RP 235 • E-LINK
10.13 Standard error:
TWINE DOES NOT RUN
TWINE DOES NOT RUN
TWINE DOES NOT RUN
TWINE DOES NOT RUN
Both twine do not run (cause for example both twine
spools empty).
The error message can be acknowledged.
Subsequently: remove cause.
Then the net tying or twine tying can be started.
Acknowledge fault messages: press key
Start twine- or net tying.
10.14 Standard error:
TWINE RUNS WITHOUT T
TWINE RUNS WITHOUT T
TWINE RUNS WITHOUT T
TWINE RUNS WITHOUT TYING
YING
YING
YING
One twine or both twines run, although no tying was
started.
The error message can be acknowledged or
disappears automatically when both twines stop
running.
Acknowledge fault messages: press key
10.15 Standard error:
1 TAILGATE HOOK OPEN
1 TAILGATE HOOK OPEN
1 TAILGATE HOOK OPEN
1 TAILGATE HOOK OPEN
A locking hook of the baling chamber is open.
The error message can be acknowledged or
disappears automatically when both locking hooks are
open or both locking hooks are closed.
Acknowledge fault messages: press key
10.16 Standard error:
MAXIMUM BALING DENSI
MAXIMUM BALING DENSI
MAXIMUM BALING DENSI
MAXIMUM BALING DENSITY REACHED
TY REACHED
TY REACHED
TY REACHED
The baling density has exceeded the value 10 in the
manual tying mode. The control remains passive:
Thus the operator must start the tying manually.
The error message can be acknowledged or
disappears automatically, when a manual tying cycle is
started. The signal tone stops buzzing when the error
was acknowledged or when manual tying was started.
Acknowledge fault messages: press key
Start tying: Press button
<START/STOP>.