Weldex WDAC-5777C Скачать руководство пользователя страница 3

2.0 Warnings

 

The camera needs periodic inspection.

Contact an authorized technician for inspection.

 

Stop using your camera when you find a malfunction.

If you use your camera around smoke or unusual heat for a long time, fire may be caused.

 

Do not Install the camera on a surface that can not support it.

Unless the surface is suitable, it could cause falling or other hazards.

 

Do not hold plug with wet hands.

It could cause an electric shock.

 

Do not disassemble the camera.

It may result in fire, electric shock or other hazards.

 

Do not use the camera close to a gas or oil leak.

It may result in fire or other hazards.

 

Digital OSD Camera Installation Guide

4

Digital OSD Camera Installation Guide

5

3.0 Precautions

Do not install the camera in extreme 

temperature conditions.

Only use the camera under conditions 
where temperatures are between -10 
Deg. C and +50 Deg. C.(14 Deg. F and 
122 Deg. F) Be especially careful to 
provide ventilation when operating 
under high temperatures.

Do not install or use the camera in an 

environment where the humidity is high.

It can cause the image quality to be 
poor.

Do not install the camera under 

unstable lighting conditions.

Severe lighting change or flicker can 
cause the camera to work improperly.

Do not touch the front lens of the 

camera.

It is one of the most important parts 
of the camera. Be careful not to be 
stained by fingerprint.

Do not drop the camera or subject 

them to physical shocks.

It can cause malfunctions to occur.

Never keep the camera face to 

strong light directly.

It can damage the CCD.

Do not expose the camera to rain 

or spill beverage on it.

If it gets wet, wipe it dry immediately. 
Liquids can contain minerals that 
corrode the electronic components.

Do not expose the camera to 

radioactivity.

If it is exposed to radioactivity, For 
heated CCD, it will be out of order.

Note

 

If the camera is exposed to spotlight or object reflecting strong light, smear or blooming may occur.

 

Please check that the power satisfies the normal specification before connecting the camera. 

Содержание WDAC-5777C

Страница 1: ...orth America 6751 Katella Ave Cypress CA 90630 Phone 1 714 761 2100 Fax 1 714 761 3811 http www weldex com oem weldex com Sale Branch Office Factory in Korea Hansol Bldg 6th Fl 322 Ha an 1Dong KwangMy...

Страница 2: ...intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance This installation should be made by a qualified s...

Страница 3: ...pecially careful to provide ventilation when operating underhightemperatures Do not install or use the camera in an environmentwherethehumidityishigh It can cause the image quality to be poor Do not i...

Страница 4: ...res Warnings Precautions Components Names and Functions of Parts Front Side Bottom Back Installation Lens Connecting to a Monitor ConnectingtoPower 1 0 2 0 3 0 4 0 5 0 5 1 5 2 5 3 5 4 6 0 6 1 6 2 6 3...

Страница 5: ...ver before adjusting the Back Focal length Digital OSD Camera Installation Guide 9 5 2 Side Auto iris lens connector This is the connection terminal for the auto iris lens 5 3 Bottom Mounting bracket...

Страница 6: ...cable to the connector pin in the plug 6 0 Installation 6 1 Lens Lenses are sold separately Lenses such as an auto iris lens CS Mount lens and C Mount lens can be used When using an auto iris lens Ple...

Страница 7: ...and attach the C Mount lens to the camera by screwing it in clockwise 6 2 Connecting to a Monitor Please connect the video output terminal located on the back of the camera to the monitor 6 3 Connecti...

Страница 8: ...reencanbeadjustedinDCmode Thebrightnesscanbeadjustedwithintherangeof1 70 Theoptimumlevelofbrightnessfortheusercanbeachieved byadjustment IfyouselecttheMANUALmode itcanbeadjustedinESCmode Please press...

Страница 9: ...he UP and DOWN buttons Please select the mode you wish to operate by pressing the LEFT or RIGHT button Please select one of the 3 modes below ATW Auto Tracking White Balance This mode can be used with...

Страница 10: ...CKLIGHT OFF SETUP LENS SHUTTER WHITE BAL BACKLIGHT AGC DNR SENS UP SPECIAL EXIT MANUAL ESC ATW OFF LOW LOW OFF BACKLIGHT ON SETUP LENS SHUTTER WHITE BAL BACKLIGHT AGC DNR SENS UP SPECIAL EXIT MANUAL E...

Страница 11: ...DNR SENS UP SPECIAL EXIT MANUAL ESC ATW OFF LOW LOW OFF 7 3 7 SENS UP Low Illuminance SENS UP helps maintain a bright clear screen image by automatically detecting changes in the level of light in lo...

Страница 12: ...nput If you press the SETUP button after moving the cursor to CLR all the letters will be erased If you want to correct a letter please move the cursor to the arrow at the bottom left of the screen an...

Страница 13: ...mode NTSC Models When the power frequency is 60Hz you can not use the line lock mode PAL Models Sync mode is fixed to INT in DC 12V input power COLOR AUTO This camera has a function which automaticall...

Страница 14: ...rates the PRIVACY mode Please press the SETUP button Please select the area you do not wish to appear from the 4 areas in AREA SEL mode Please select ON mode for the chosen area Please adjust the size...

Страница 15: ...ens is being used and adjust the brightness level Please check if an appropriate power source to the camera complies with the manufacturer s standard requirement or if the voltage keeps changing Digit...

Страница 16: ...lor 0 1Lux F1 2 B W 0 002Lux Sens up ON AUTO OFF LOW MIDDLE HIGH ATW AWC MANUAL 1 800 K 10 500 K OFF AUTO Built in ON OFF 4 Programmable Zone OFF LOW MIDDLE HIGH Noise Reduction Built in Horizontal Im...

Отзывы: