perform the treatment on dry skin or let the handle directly touch skin.
15. Clean the instrument with normal saline (do not use ethyl alcohol) after operation to ensure
its cleanliness and hygiene and prolong its service life.
16. 40K handle should not be used on head, chest, breast, heart and back.
17. Use this machine or train the operators in strict accordance with instructions in the user
manual.
1. Troubleshooting & Solutions
1. The instrument cannot be started, and the button light on the back of the instrument does
not work?
A. Make sure the power cord is connected to the socket with normal power supply.
B. Whether the fuse on the back of the instrument is loose or blown.
1. The machine works for a while but then stops?
A. It may be because there is no strong water flow or the machine doesn’t sense the presence of
water flow.
B. Check whether there is enough water in the water container.
2. There is a red alert on the top right corner of the machine?
A. Please check whether the water level in the water container is low
B. Please check whether there is something wrong with the water container.
4. No RF output from the instrument?
A. Please check whether the cord connects the handle to the machine properly
B. Please check whether the treatment area has been cleaned. Grease or essential oil products
may cause poor contact between the handle and human body to cause this problem.
5. Weakened RF output?
A. Please check whether the cord connects the handle to the machine properly
B. Please check whether non-conductive grease and other substances are on the treatment
handle, which can cause poor contact between the handle and skin to weaken the output.
C. Please check whether the handle used is the one specified by the instrument.
6. I can start the instrument, but the screen shows erroneous message?
A. Please unplug the power plug behind the instrument and wait for about 1 minute before
restarting the instrument.
B. If the above method cannot solve the problem, please contact the instrument dealer for
assistance.
6. FAQs
1. Does the vacuum&cooling handle have side effects in reducing fat?
A: It is a totally non-invasive and painless. Based on the fact that adipose cells are more
vulnerable to coldness than other cells, it can cool down adipose cells and remove them. What’s
more, it only targets adipose cells instead of other tissue, and so it will not cause damages to
skin or muscles. The dead cells will be excreted from body through metabolism, so it has no side
effects.
2. Is the vacuum&cooling treatment effective for reducing fat?
A: The triglyceride contained in fat can change its form into solid under the low temperature of
5
℃
. If the handle is put on the fat area, fat will quickly congeal into jelly-like substances.
And