36
2.3 Installation: air recirculation
If you do not use an exhaust air pipe to the outside for the
installation of the extractor hood, the exhaust hose is not
required.
The installation of the extractor hood is similar to chapter 2.2
Installation: exhaust air operation -Installation steps- (please
ignore point 5. and point 6.).
WARNING!
Unplug the appliance or disconnect it from the mains
(use the relevant fuse in your household fuse box).
WARNING!
Use the carbon filters in recirculation mode only.
(1)
Remove the grease filter(s).
(2)
The carbon filters are intended to be installed on both sides of
the motor.
(3)
Place the carbon filter on the motor and turn it clockwise
until it is firmly tightened (s. fig. below).
A
Motor
B
Carbon filter
C
Clockwise rotation = Place the carbon filter on the motor und
turn the filter clockwise until it is installed properly.
(4)
Repeat the procedure on the other side of the motor.
(5)
Install the grease filter(s).
(6)
If you want to uninstall the carbon filters, turn the filters anti-
clockwise and remove them.
NOTICE!
If the carbon filters are installed, the suction power is
reduced.