Welch 2511 Скачать руководство пользователя страница 20

Welch Rietschle Thomas

Vacuum Pump Repair Facility

 

 

 

 

 

 

7301 North Central Avenue

 

 

 

 

 

 

Skokie, IL  60077

 

 

 

 

 

 

Phone: (847) 676-8800 

 

 

 

 

 

 

Fax: (847) 677-8606 (Technical Support)

 

 

 

 

 

 

Fax: (920) 451-4397 (Ordering) 

Copyright© 1997-2004 Welch Rietschle Thomas       

Welch is registered trademarks of Welch Rietschle Thomas

Содержание 2511

Страница 1: ...chnical Support Fax 920 451 4397 Ordering E Mail welchvacuum thomasind com Part No 67 1772R1 1 Web Page www welchvacuum com Printed in USA For outside of U S and Canada contact your local Rietschle Thomas sales office see back page Approval Agency s Warning Not recommended for pumping acid base or organic vapors or gases Model 2515B 75 Model 2511B 75 2511C 75 Model 2515C 75 ...

Страница 2: ...re failure to observe the instruction could result in damage to the equipment associated equipment and process These units confirm to the SI International system of units of measurement The following symbols with recommendation of IEC1010 of warning will be found on the pump Caution refer to accompanying documents Caution risk of electrical shock Caution hot surface Double Insulated OFF Power ON Po...

Страница 3: ...3 OPERATION 3 10 Starting Procedures 3 20 Leak Detection 3 30 Operating Pressure Range 3 40 Shutdown Procedures Section 04 MAINTENANCE 4 10 Maintenance Procedures Section 05 TROUBLESHOOTING 5 10 Vacuum Problems 5 20 Pressure Problems 5 30 Trouble Shooting Guide For 2515 5 40 Trouble Shooting Guide For 2511 And 2515 Section 06 SPECIFICATION 6 10 Specification Table Section 07 WARRANTY Section 08 EXP...

Страница 4: ...t determining maximum air pressure for that tool or attachment applies to model 2511 only Be sure to properly identify intake and discharge before using pump See Section 2 50 WARNING Do not fill the collection jar above the safe fill level line indicated on the jar 1 20 Caution To Reduce Risk Of Electrical Shock 1 21 Do not disassemble Disassembly or attempted repairs if accomplished incorrectly can...

Страница 5: ...ons involving a semi flexible surface such as a bench top they help to isolate noise and eliminate creeping All Aspiration Filtration Vacuum Systems should be mounted on a horizontal plane 2 40 Pump Location 2 41 The Aspiration Filtration Vacuum System should be located preferably in a clean dry and well ventilated area Please be sure not to block the ventilation holes located on the motor housing ...

Страница 6: ...eric and the maximum possible for the pump model Model 2511 is equipped with a pressure port Note Adjusting the vacuum regulators will affect the performance of the pump WARNING Never block the discharge port If the exhaust is blocked pressure will build up in the pump above its rated operating pressure Be sure to call Welch technical service prior to start up at 847 676 8800 if you have any quest...

Страница 7: ...ld a means for grounding to be added to the product Servicing of a double insulated product requires extreme care and knowledge of the system and should be done only by qualified service personnel Replacement parts for the double insulated product must be identical to those parts in the product 2 64 Classification And Symbol Glossary 2 70 Vacuum Connection 2 71 For best results Welch recommends the ...

Страница 8: ... vacuum level by turning the regulator knob counter clockwise to increase vacuum or clockwise to decrease vacuum Note This procedure should be performed each time you use this device 3 12 Cleaning The Device 1 Make sure the ON OFF switch is in the OFF down position 2 Unplug the device from the wall outlet and allow suction level to drop 3 Remove the application tube from the lid vacuum port Tubing...

Страница 9: ...Filtration Vacuum System These units are 100 oil free The pump employs a non lube piston and cylinder No maintenance is necessary for the bearings All bearings are sealed and permanently lubricated Lubrication should not be attempted The units are built for continuous duty operation with the quietness and durability of a diaphragm but with piston performance 4 12 Hydrophobic Filter Replacement Cha...

Страница 10: ...e See Section 2 80 5 20 PRESSURE PROBLEMS 5 21 Leakage and contamination are the general causes of problems associated with poor pressure To operate at maximum efficiency a system must be thoroughly clean If the system is completely clean and free from leaks and unwarranted pressure problems still exist the pump compressor should be checked by a service technician 5 30 TROUBLE SHOOTING GUIDE FOR 25...

Страница 11: ... 2 Defective switch 2 Contact your service center or distributor See back page 3 Vacuum still exists 3 Disconnect tubing from the in system collection jar to release vacuum Reconnect tubing and turn on the device Gauge reads 1 Faulty gauge 1 Contact your service incorrectly center for repair 410 712 4100 Device runs but 1 Gauge tubing not 1 Check the tubing and gauge reads connected or is connecto...

Страница 12: ...1 0 32 9 2 0 39 11 1 2 34 1 0 28 1 2 34 Maximum Vacuum in Hg Ultimate Vacuum Torr mbar Dimensions L x W x H in cm Shipping Weight lbs Electrical Requirements 115V 60 Hz 230V 50Hz 100V 50 60Hz 115V 60 Hz 230V 50Hz 100V 50 60Hz 6 4 19 27 2 219 292 70 93 11 0 x 8 3 x 10 0 28 x 21 x 25 5 14 8 x 8 3 x 10 0 37 5 x 21 x 25 5 21 3 Model 2511 Model 2515 12 ...

Страница 13: ...thod of executing this warranty servicing adjusting repairing or replacing shall be at the discretion of Welch Rietschle Thomas Vacuum pumps that have been used for any period however short will be repaired under this warranty rather than replaced The warranty is effective for one year from the date of original purchase when 1 The warranty card has been completed and returned 2 The product is retu...

Страница 14: ...N 8 EXPLODED VIEW PARTS LIST 8 10 Model 2511B 75 2511C 75 2511C 76 PUMP ON OFF SWITCH REGULATOR KNOB VACUUM GAUGE SHORT TUBING LONG TUBING APPLICATION TUBING HYDROPHOBIC FILTER PRESSURE PORT COLLECTION JAR 14 ...

Страница 15: ...8 11 Model 2515B 75 2515C 75 2515C 76 COLLECTION JAR LONG TUBING APPLICATION TUBING HYDROPHOBIC FILTER PUMP ON OFF SWITCH REGULATOR KNOB VACUUM GAUGE SHORT TUBING 15 ...

Страница 16: ...8 12 Model 1475K 20 COLLECTION JAR LONG TUBING APPLICATION TUBING HYDROPHOBIC FILTER SHORT TUBING 16 ...

Страница 17: ...9 10 REPAIR KITS 9 11 Repair Kit for Model 2515 Service Seal Gasket Description Kit Kit 2515K 01 2515K 02 Connecting Rod Assembly 1 1 Handle Screw 2 2 Head Screw 3 4 Head O Ring 4 1 1 Valve Plate Assembly 5 1 Cylinder O Ring 6 1 1 17 ...

Страница 18: ... Adapter for dispoable tips w o ejector 1475K 03 Rubber Adapter for Pasteur pipettes 1475K 04 8 Channel Adapter for dispoable tips w ejector 1475K 05 Adapter S S 150mm 1475K 06 4 Channel Adapter S S 40mm 1475K 07 Adapter S S 280mm 1475K 08 1 Channel Adapter for dispoable tips w ejector 1475K 09 Vacuboy Hand Operator w 1 Channel Adapter S S 1475K 10 18 ...

Страница 19: ...cription Welch Kit 115V 60Hz Maintained on off footswitch 1430A 115V 60Hz Variable on off footswitch 1430B 90 230V 50 60Hz Variable on off footswitch with IEC connections 1430C 19 Description Welch Kit Aspiration Kit Includes 6 ft tubing 2000ml Autoclavable jar w lid and two hydrophobic filters 1475K 20 ten hydrophobic filters 1475K 21 ...

Страница 20: ...Repair Facility 7301 North Central Avenue Skokie IL 60077 Phone 847 676 8800 Fax 847 677 8606 Technical Support Fax 920 451 4397 Ordering Copyright 1997 2004 Welch Rietschle Thomas Welch is registered trademarks of Welch Rietschle Thomas ...

Отзывы: