Welch Allyn

®

 

WAM™ PC 

W

IRELESS 

A

CQUISITION 

M

ODULE WITH 

M

EMORY

 

USER MANUAL 

 

 

 

 

 

 

 

 
 
 
 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Manufactured by Welch Allyn. Inc., Skaneateles Falls, NY USA 

 

 

CAUTION:  Federal law restricts this device to sale by or on the order of a physician

 

 

Содержание WAM PC

Страница 1: ...Allyn WAM PC WIRELESS ACQUISITION MODULE WITH MEMORY USER MANUAL Manufactured by Welch Allyn Inc Skaneateles Falls NY USA CAUTION Federal law restricts this device to sale by or on the order of a phys...

Страница 2: ...ows are trademarks or registered trademarks of their respective owners For patent information please visit www welchallyn com patents For information about any Welch Allyn product visit https www welc...

Страница 3: ...FACTURER S DECLARATION ELECTROMAGNETIC IMMUNITY 8 WARRANTY INFORMATION 11 YOUR WELCH ALLYN WARRANTY 11 USER SAFETY INFORMATION 12 EQUIPMENT SYMBOLS AND MARKINGS 15 CARE AND MAINTENANCE 16 PRECAUTIONS...

Страница 4: ...TABLE OF CONTENTS Page 2 ACQUIRING ECG WAVEFORMS 23...

Страница 5: ...eference number on the back of the device Care should be taken so that these numbers are not defaced For questions and service information have both serial and part numbers available when calling The...

Страница 6: ...ications Commission FCC The device with its antenna complies with FCC s RF exposure limits for general population uncontrolled exposure FCC Warning Part 15 21 Changes or modifications not expressly ap...

Страница 7: ...erased from the device nor stored in the receiving application ensuring that partial or corrupted data are not made available to the receiving application If the failure mode persists the user should...

Страница 8: ...can affect the performance of medical equipment See the table below for recommended separation distances between the radio equipment and the device The use of accessories and cables other than those s...

Страница 9: ...supply lines 1 kV for input output lines 2 kV for power supply lines 1 kV for input output lines Mains power quality should be that of a typical commercial or hospital environment Surge IEC 61000 4 5...

Страница 10: ...r and d is the recommended separation distance in meters m Field strengths from fixed RF transmitters as determined by an electromagnetic site surveya should be less than the compliance level in each...

Страница 11: ...aximum Output Power of Transmitter W Separation Distance According to Frequency of Transmitter m 150 KHz to 800 MHz 800 MHz to 2 5 GHz P d 2 1 P d 3 2 0 01 0 1 m 0 2 m 0 1 0 4 m 0 7 m 1 1 2 m 2 3 m 10...

Страница 12: ...ELECTROMAGNETIC COMPATIBILITY EMC Page 10...

Страница 13: ...er charges with respect to any Product s returned to Welch Allyn s principal place or any other place as specifically designated by Welch Allyn or an authorized distributor or representative of Welch...

Страница 14: ...arm to users patients and bystanders or damage to the device To maintain designed operator and patient safety peripheral equipment and accessories used that can come in direct patient contact must be...

Страница 15: ...e of strong electromagnetic sources such as electro surgery equipment Use only recommended battery cells Use of other cells may present a risk of fire or explosion Low battery warning function is desi...

Страница 16: ...ce See ELECTROMAGNETIC COMPATIBILITY EMC for guidance Do not sterilize the device or patient cables with Ethylene Oxide EtO gas Improper cleaning products and processes can damage the device produce b...

Страница 17: ...art Acquire 12 Lead ECG waveforms button Power on off button Battery orientation with notification see operating instructions for type of cell to be used Do not dispose as unsorted municipal waste Per...

Страница 18: ...dium hypochlorite 50 000 ppm free chlorine use nothing more concentrated than a 10 bleach solution 1 10 dilution or 1 part bleach to 9 parts water yielding 5 000 ppm free chlorine as recommended by th...

Страница 19: ...to its memory Once it has 60 seconds of data it is placed near a computer with a USB Transceiver Key UTK A software application is used to wirelessly copy the waveforms from the module After the wavef...

Страница 20: ...amples second channel acquisition 1 000 samples second channel analysis and storage Voltage Resolution 1 875 microvolts User Interface Power and acquisition buttons Feedback with orange green LED and...

Страница 21: ...ed to the computer Each WAM PC can only be paired with one UTK and each UTK can only be paired with one WAM PC Pairing is normally a one time setup task but it can be performed again when necessary Pa...

Страница 22: ...ired when the electrodes are placed on the patient in the correct positions Refer to Electrode Positions WARNING Incorrect electrode placement could alter the ECG waveforms enough to cause ECG signal...

Страница 23: ...Green Midway between V2 C2 and V4 C4 electrodes Blue Brown On the 5 th intercostal space at the left midclavicular line Orange Black Midway between V4 C4 and V6 C6 electrodes Violet Violet On the lef...

Страница 24: ...aveforms into memory Flashing Green 2 ticks per second Acquiring new waveforms into memory but a lead wire has become disconnected Solid Green Waveforms have been stored in memory It is not ready to a...

Страница 25: ...ng between Orange and Green it is ready to acquire new waveforms but one or more of the lead wires are disconnected from the patient c Solid Orange it is ready to acquire new waveforms and all the lea...

Страница 26: ...ime the WAM PC will automatically clear its memory and make itself ready to acquire new waveforms It will beep two times a second while it clears memory It will remain on and the LED will either be so...