Serial Commands Summary C–3
C.4
Default Configuration Settings
The following is a summary of default configuration settings.
Configuration CommandDefault Settings
ACK / NAK
Disabled
Baud Rate
9600
Beeper Mode
Disable beeper
Data Bits:
7
No Read Message
“NR”
Parity
Even
Postamble
CR LF
Preamble
Port ID Code ID
Read Timeout
Timeout ends a read attempt, 1.5 seconds
RTS/CTS
Disabled
Stop Bit:
1
Trigger Mode
Serial Trigger or External Trigger, Read
Once
Votes
3 votes for port 1 and 1 vote for port 2
XON/XOFF
Disabled
Symbology Configuration
Default Settings
Codabar
Enabled
Send Start/Stop
Yes
Minimum Length
6
Maximum Length
60
Code 39
Enabled
Require Checksum
No
Send Checksum
No
Minimum Length
1
Maximum Length
48
Code 128
Enabled
Minimum Length
1
Maximum Length
80
EAN 8/13
Enabled
I 2 of 5
Disabled
Require Checksum
No
Send Checksum
No
Minimum Length
6
Maximum Length
80
UPC A/E
Enabled