Welch Allyn RPM-Scale100 Скачать руководство пользователя страница 17

2.Increase the separation between the equipment and receiver.

3.Consult the dealer or an experienced radio/TV technician for help.

Any changes or modifications not expressly approved by the party responsible for

compliance could void the user's authority to operate this equipment.

FCC Radiation Exposure Statement

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled

environment. This transmitter must not be co-located or operating in conjunction with

any other antenna or transmitter.

Industry Canada (IC) compliance

To ensure compliance with FCC and Industry Canada RF exposure requirements, this

device must be installed in a location where the antennas of the device will have a

minimum distance of at least 20 cm from all persons. Using higher gain antennas and

types of antennas not certified for use with this product is not allowed. The device shall

not be co-located with another transmitter.

Installez l'appareil en veillant à conserver une distance d'au moins 20 cm entre les

éléments rayonnants et les personnes. Cet avertissement de sécurité est conforme aux

limites d'exposition définies par la norme CNR-102 at relative aux fréquences radio.

This device complies with Industry Canada licence-exempt RSS standard(s). Operation is

subject to the following two conditions: (1) this device may not cause interference, and

(2) this device must accept any interference, including interference that may cause

undesired operation of the device.

Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils

radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1)

l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter

tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en

compromettre le fonctionnement.

This radio transmitter (IC ID: 12725A-BS1507) has been approved by Industry Canada to

operate with the antenna listed in the specification table.

This Class B digital apparatus complies with Canadian ICES-003.

Cet appareil numérique de la classe B est conform à la norme NMB-003 du Canada

Complied standards list

Item

Standard

Risk management

ISO/EN 14971 Medical devices — Application of risk

management to medical devices

Labeling

ISO/EN 15223-1 Medical devices. Symbols to be used with

medical device labels, labeling and information to be

supplied. General requirements
Tested in accordance with ISO 10993 Biocompatibility

Directions for use 

Appendices  13

Содержание RPM-Scale100

Страница 1: ...Welch Allyn Remote Monitoring Scale RPM Scale100 Directions for use 901077 Weight scale Software Version 1 0...

Страница 2: ...yright 2015 Welch Allyn or its vendors All rights are reserved The software is protected by United States of America copyright laws and international treaty provisions applicable worldwide Under such...

Страница 3: ...5 Use the scale 7 Startup 7 Insert or replace the batteries 7 Pair a connection hub with the scale 7 Select the measurement unit 8 Obtain measurement 8 Stop a measurement 8 Maintain the scale 8 Troub...

Страница 4: ...iv Contents Welch Allyn Remote Monitoring Scale RPM Scale100...

Страница 5: ...ch Allyn Remote Monitoring Scale is intended for adults and children 10 17 years old to measure weight in home Contraindications This device is contraindicated for any person who is connected to a wea...

Страница 6: ...ooth wireless technology enabled Miscellaneous symbols Serial number Manufacturer Product identifier product family catalogue number Non ionizing electromagnetic radiation Reorder number Model number...

Страница 7: ...Warning Patient injury risk Do not jump onto the platform immediately after bathing or with wet hands Warning Patient injury risk Keep the device clean Patient contact with contaminated equipment can...

Страница 8: ...ance d 3 3m away from the equipment Note As indicated in Table 6 of IEC 60601 1 2 2007 for ME Equipment a typical cell phone with a maximum output power of 2 W yields d 3 3m at an IMMUNITY LEVEL of 3V...

Страница 9: ...ter pairing mode 3 Battery compartment behind cover Houses 4 AAA alkaline batteries 1 5V each 4 Sensors 4 4 load cell sensors which conduct weight measurement Screen elements The liquid crystal displa...

Страница 10: ...battery charge Full battery charge Bluetooth wireless technology is powered on Bluetooth wireless technology connected dotted area is not flashing Data being transferred using Bluetooth wireless techn...

Страница 11: ...ries may leak or explode 1 Open the battery door on the under side of the scale The digits 8888 appear on the LCD screen 2 Insert the four AAA alkaline batteries 1 5V each into the battery compartment...

Страница 12: ...s on and begins the measurement 2 Stand still and keep full contact with the scale until the LCD stops blinking and displays the weight Stop a measurement You can stop a measurement before it is compl...

Страница 13: ...t acquisition an error code will be displayed in the LCD area The message will persist for several seconds until the device times out and powers down Check the following items Bluetooth wireless techn...

Страница 14: ...echnology is off Turn on the Bluetooth wireless technology via the Settings Application is off Press the icon to run your application Out of range of Bluetooth transmission Place your mobile or portab...

Страница 15: ...0 100kg 0 1kg 100 200kg 0 2kg 0 220 lb 0 2lb 220 440lb 0 5lb 100 150kg 0 5kg 150 200kg 0 7kg Normal working condition Temperature 5 to 40 Humidity 85 RH Atmospheric pressure 86kPa to 106kPa Division...

Страница 16: ...rference received including interference that may cause undesired operation This equipment FCC ID OU9BS 1507 has been tested and found to comply with the limits for a Class B digital device pursuant t...

Страница 17: ...2 at relative aux fr quences radio This device complies with Industry Canada licence exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference...

Страница 18: ...dard Usability Emissions and immunity information The Welch Allyn Remote Monitoring Scale RPM SCALE100 is intended for use in the electromagnetic environment specified below The customer or user of th...

Страница 19: ...ESD IEC 61000 4 2 6 kV contact 8 kV air 6 kV contact 8 kV air Floors should be wood concrete or ceramic tile If floors are covered with synthetic material the relative humidity should be at least 30 E...

Страница 20: ...1 GHz 3 V m d 1 167 80 to 800 MHz d 2 333 800 MHz to 2 5 GHz wherePis the maximum output power rating of the transmitter in watts W andd is the recommended separation distance in meters m Field stren...

Страница 21: ...7 1 167 2 333 10 3 690 3 690 7 338 100 11 67 11 67 23 33 For transmitters rated at a maximum output power not listed above the recommended separation distanced in meters m can be estimated using the e...

Страница 22: ...device require maintenance or replacement at our option under warranty please deliver the original package to Welch Allyn prepaid Please return the store receipt with the retail purchase date and a n...