 Subject: 

Replacing the Infinite Switch, from old Robertshaw to the new EGO

NOTE:

 In order to connect the same wire to the new 

switch, as per the above diagram of equivalence, 

follow the steps below:

7.  Cut the wire from the old switch.

8.  On the piece of wire 

remaining on the 

harness, strip its end 

3/8”.

9.  Insert the stripped end of the wire into the 

WAGO connector (corresponding the activation 

lever lifted of the WAGO connector)

10.  Lock the stripped 

end of the wire into 

the WAGO connector 

by lowering its 

corresponding 

activation lever tab.

11.  Insert and lock 

one of the wires 

provided in the kit 

into the same WAGO 

connector. 

12.  Connect the newly installed wire onto its proper 

terminal of the new switch provided with the kit, 

as per the schematic of equivalence

13.  Repeat all the steps above to complete the 

whole wiring transfer from the old switch to the 

new.

14.  Install and secure back the new infinite switch to 

the panel and also re-install the panel.

15.  Plug in and test the unit.