Exhaust gas temperature
The temperature of the undiluted exhaust gas can reach 500 °C.
Follow fire safety regulations.
6.2.2 Positions of the fan burners and main gas valve
Position of the gas burners
The following illustration shows a size 6.10 combi oven with boiler as an example of all appliance sizes:
Item
Name
1
Exhaust outlet from boiler burner (only on models
with boiler not steam injection)
2
Exhaust outlet for convection burner
3
Convection burner
4
Main gas valve, connection to gas supply in appli-
ance floor
5
Boiler burner (only on models with boiler not
steam injection)
6.2.3 Installing the gas
Requirements
Check that the following requirement has been met:
■
A gas shut-off device is installed at the customer's premises.
Materials required
■
Leak detector spray/gas detector
Installing the gas
1.
Compare the type of gas, the gas pressure and the rating for the gas supply
connection with the data given on the appliance type plate.
The appliance must not be connected to the gas supply or put into use unless
the values match those on the type plate.
'Data for gas operation' in 'Technical data' on
2.
Connect to the gas supply.
3.
Make sure that all the connections outside the appliance are gastight.
4.
Find out about the construction and position of the burner, and the layout of its
parts.
Positions of the fan burners and gas distribu-
5.
Switch on the appliance.
6.
Make sure that all the connections outside and inside the appliance are gas-
tight. Seal any connections that are not gastight.
7.
Start a cooking profile in the Convection operating mode.
6 Installation
Installation manual
49