6.3.3 Drain connection
Rules for safe installation of the drain connection
Observe the following rules to prevent hazards caused by a faulty drain connection:
■
There must be no restriction or reduction in the cross-section of the drain pipe.
■
The slope of the drain pipe must equal min. 3.5% (2°).
■
If more than one appliance is connected to one drain pipe, this pipe must be large enough to allow
the wastewater to flow out unchecked.
■
The appliance must be connected to the drain using a NON-flexible pipe. A fixed connection is rec‐
ommended; alternatively an open funnel waste trap can be installed.
Regulations for the drain connection
You must comply with local and national regulations on the design of the drain connection and on the
composition of the wastewater. These include:
■
DIN 1988 part 2 and part 4
■
DIN EN 1717
■
Local waste water regulations
Connection diagram
Item
Name
Function
1
Safety overflow
■
On the appliance floor,
connection point M, see
■
Used to drain away water
in the event of a fault
(blockage).
2
Appliance drain On the appliance floor, con‐
3
Drain pipe DN
50
■
Minimum internal diame‐
ter = 46 mm
■
Slope min. 3.5% (2°)
4
Waste trap /
Funnel waste
trap
Recommended for blocking
smells
5
Drain pipe DN
50
■
Minimum internal diame‐
ter = 46 mm
■
Slope min. 3.5% (2°)
Connecting the appliance to the drain
Connect the appliance as shown in the connection diagram. Use the flat bend supplied.
6 Installation
Installation manual
45