Welbilt Cleveland 24CDM Скачать руководство пользователя страница 14

Operator’s Manual

______________________________________________________________________________

 

9

On the Convection Steamer registers 10 psi, steamer
preheating may begin. Skip the remainder of step I, and
begin step 2.

For units with a built-in boiler, fill the boiler with water

and start the steam generator as described in step a.
through d. below.

a.

Press the ON end of the POWER on-off rocker switch

located next to the steam pressure gauge (Figure 2).
The red indicator light in the POWER rocker switch
turns on and the steam generator begins to fill with
water units takes about 5 minutes.

b. When the water level in the steam generator reaches a

safe operating level, the amber light in the STEAM
momentary switch turns on. Whenever the amber light
is on, the heaters, steam supply, or burners are 

off,

and no steam is being generated. The energy source
(electric, gas, etc.) cannot be activated until the boiler
contains sufficient water, indicated by the amber light.

c. Press the STEAM (amber colored) momentary switch

to produce steam in the boiler this activates the energy
source (electric heaters, gas burners, or steam so-
lenoid valve) and the amber light turns off.

The STEAM switch must be pressed to restart the

steamer after it is shut off for any reason (including a
brief power interruption). No attempt should be made
to operate the equipment during a power failure.

NOTE:

For steamers with built-in gas-fired boilers: If the
burners fail to ignite in four seconds, a safety
circuit energizes the system. In this event toggle
the POWER rocker switch to the OFF position
and back to the ON position. The amber light in
the STEAM momentary switch lights. Wait five
minutes, and then press the STEAM momentary
switch to start the burner ignition cycle once
again.

d. About 20 minutes after starting the boiler in step C; the

steam pressure gauge on the unit base should register
10 psi.

2. Preheat the Convection Steamer cooking

compartments. For accurate, efficient cooking times, the
cooking compartments should be preheated during
startup.

NOTE: With a steamer/kettle combination, if both must

be used at the same time, always heat the kettle
first. When kettle contents begin to simmer,
steam pressure returns, the steamer
compartments may be preheated

a. Close the compartment door by gently swinging it shut.

b. Refer to timer setting instructions under Automatic

Operation for the appropriate control panel. Set the
Timer for each compartments to one minute, and start
the cooking cycles. Steaming begins in each compart-
ment.

NOTE: On Convection Steamers equipped with

electronic key pad control panels, the timer does
not begin counting down until the cooking
compartment reaches operating temperature.
This may take 2 or 3 minutes if the steamer has
not been operating.

c. Steaming continues for the set one minute. When the

preheating is completed, the steam automatically shuts

off 

and a 3-second alarm sound. The Convection

Steamer is ready for cooking operations.

COOKING OPERATIONS

The control panels mounted on the cooking compartments
regulate cooking operations. Although cooking operations
are similar for all Convection Steamers, regardless of con-
trol panel configuration, separate instructions are provided
for each control panel type.

Cooking Operations for
The Key Pad Control Panel

The electronic keypad control panel illustrated in Figure 3.

The Cleveland Range Convection Steamer has two cook-
ing modes: Manual and automatic. The Manual Mode
provides continuous steaming and is turned on and off by
the MANUAL/TIMED rocker switch. The Automatic Mode
monitors cooking time and compartment temperature to
provide accurate, efficient, uniform steam cooking.

NOTE:

Whether using timed or manual cooking modes,
optimum steam heat transfer, and therefore a
higher quality food product, is achieved when
shallow, perforated, uncovered pans are used.

WARNING

STEAM may cause severe burns. Use extreme
Caution when opening the steamer door. Turn face away
from the steamer when first opening the door. Do not look
into the cooking compartment until steam has dewed.
KEEP HANDS OUT OF THE COOMNG
COMPARIMENTTO PREVENT BURNS.

Manual Cooking Operation -
Key Pad Controls

Use manual mode for a continuous supply of steam for
long periods, or if the required cooking time is unknown
and frequent inspection is required.

1.

Place the pan(s) of food into the compartment.

Содержание Cleveland 24CDM

Страница 1: ...models are released Visit our website for the latest manual Convection Steamer Part KE004031 2 C MODELS 24 36CGM CEM CSM CDM 42CKGM CKEM CKSM CKDM 36CGM16300 36CEM1648 36CSM16 36CDM16 For your future...

Страница 2: ...nformer aux mesures de s curit normalis es de l industrie y compris mais sans s y limiter les r glementations de l OSHA les proc dures de d branchement verrouillage tiquetage relatives tous les servic...

Страница 3: ...juste modificaci n servicio o mantenimiento puede ocasionar da os a la propiedad lesiones o muerte Lea detenidamente las instrucciones de instalacion y de operaci n antes de instalar poner a funcionar...

Страница 4: ...de presi n Keep clear of pressure relief discharge Restez l cart de la soupape de suret Permanezca alejado de la descarga de presi n Do not lean on or place objects on the equipment Ne vous penchez p...

Страница 5: ...artment Control Panels 8 Start up and Preheat 8 Cooking Operations 9 Cooking operations for the Key Pad Control Panel 9 Manual Cooking Operation Key Pad Controls 9 Automatic Cooking Operation Key Pad...

Страница 6: ...ier s instructions If the gas supplier cannot be reached call the fire department C Operational Safety The Operational Safety section outlines minimum safety policies and procedures for operating one...

Страница 7: ...vice representative BURN and SCALD HAZARD Exposure to steam condensate and hot surfaces can cause death burns and scalds To help avoid injury Do NOT breathe steam or condensate Stand on the hinge side...

Страница 8: ...__________________________________ Serial Number____________________________________________________________ Write the Serial Number of your appliance here C PRODUCT INFORMATION PLATE The Product Info...

Страница 9: ...EMENTS for your STEAMER are as follows Total Dissolved Solids less than 60 parts per million Total Alkalinity less than 20 parts per million Silica less than 13 parts per million Chloride less than 30...

Страница 10: ...C22 1 The installer A wiring diagram is provided inside the base cabinet must ground equipment that is connected to electricity WARNING INJURY TO PERSONNEL AND EQUIPMENT DAMAGE May result from an impr...

Страница 11: ...tors Electric supply must match power requirements specified on the data plate inside the base cabinet The copper wiring size must be adequate to carry the required current at the rated voltage A sepa...

Страница 12: ...at the water in the boiler sight gauge glass automatically stays about 1 3 full when boiler is started up and operated 12 Check to ensure that the steam pressure gauge registers 10 psi The steam press...

Страница 13: ...m supply may also be used Units with a built in boiler have both the POWER rocker switch and the STEAM momentary switch next to the pressure gage Units with no internal generator have the POWER rocker...

Страница 14: ...if both must be used at the same time always heat the kettle first When kettle contents begin to simmer steam pressure returns the steamer compartments may be preheated a Close the compartment door by...

Страница 15: ...s for the seconds If the cooking time is 99 seconds or less only press the number keys for seconds b Example 1 To set the timer for 1 hour and 15 minutes Change 1 hour 60 min and 15 minutes to 75 minu...

Страница 16: ...witch Automatic Cooking Operation Dial Timer Controls Each Convection Steamer cooking compartment is equipped with an independent dial timer This timer con trols cooking compartment steaming cycle Use...

Страница 17: ...e cleaners and cleaning procedures as for other kitchen surfaces of stainless steel and aluminum Mild soapy water with a dear water rinse is recommended DO NOT ALLOW WATER TO RUN INTO ELECTRICAL Contr...

Страница 18: ...041B Descaling Procedure Convection Steamers a Inspect more frequently in areas where the water con ditions do not meet the Water Quality Requirements 1 Change the boiler gasket every time you open th...

Страница 19: ...is clogged Clean water supply strainer Water sensors shorted by scale Descale steam generator with USDA Deposits Approved descaler Inoperative controls or solenoid See note 1 Steam Generator does not...

Страница 20: ...or drain lines Food takes too long to cook Not enough steam movement in Make proper connections Refer to Service Cook in perforated pans when compartment Hot water con Manual possible Connected to co...

Страница 21: ...and savory and is easily sliced Desserts Many kinds of cornstarch pudding and custard desserts are prepared by steaming Fruit desserts such as steamed Baked Apples are another suggestion Core the appl...

Страница 22: ...0ml 60 Mashed Potatoes 2 oz 60ml 120 Sauce 1 oz 30ml 240 Number of servings of cooked vegetables from one 12 x 20 x 2 perforated pan 65mm 1 1GN Frozen Vegetables Yields 10 0 lbs 4 5kgs Approx 50 3 oz...

Страница 23: ...5 3 4 Whole 10 Celery Dai Cut 1 3 Diced 2 1 Minced 1 Corn yellow whole 2 On cob 6 12 Cobbettes 6 12 Eggplant sliced 1 Mixed Vegetables 3 4 Mushrooms Whole 1 3 Sliced 1 Onions diced sliced 2 3 1 Whole...

Страница 24: ...1 1 2 minutes on each side This well done steak shrinks less is more tender and juicy and when served is the same size as the rare steak Sirloin Patties Chopped 8 oz 4 min Ribeye 8 oz 4 min Top butt s...

Страница 25: ...Operator s Manual ___________________________________________________________________________20 NOTES...

Страница 26: ...itchencare com To learn how Welbilt Foodservice and its leading brands can equip you visit our global web site at www welbilt com then discover the regional or local resources available to you Every n...