3 Technical data
Merrychef conneX
®
service and repair manual
27
Description
Features
Function
Rating
Trouble shooting
Cooling Fan
Supplies fresh air into
the component
chamber to cool down
the electrical
components. The fan
should run counter
clockwise (looking
down from above). The
fan will continue to run
until the oven is
switched off after
cleaning cycle.
Motor has internal
Thermal Overload
Protection on the Live
Supplies fresh air into
the component
chamber to keep the
electrical components
cool. Fan should run
counter clockwise.
Draws air in through
the filter under the
door and out the rear
of the oven
230VAC, 0.23A 52W @
50Hz / 0.3A 70W @
60Hz
Resistance: 198 - 222
Ω
(222
Ω
across
connection terminals).
Capacitor 1.5
µ
F
Check operation in
Diagnostic View
Check for opens, shorts
or grounds
Check for locked rotor
(Power Off)
Check IO connection
X110
Check IO LED28
Check for Live supply
potential on fan
connection
Check Event Log for IO
& UI temperatures and
E103 events
Cooling Fan Capacitor
Connects to the cooling
fan at the connection
plug
Stores and discharges
voltage to start and run
the cooling fan motor
400V, -25/70
o
C, 1.5
µ
F
±
5%
Check for proper
microfarads.
Check for opens,
shorts, or grounds.
Warning: Capacitor
may have a stored
charge, discharge
before testing
Stirrer Motor(s)
Mounts directly on the
wave guide above the
cavity, supply voltage
connected directly
from the IO Board.
Driving the stirrer
antennae in the horn
area of the microwave
launch on the cavity,
through the gear
assembly
Drives a stirrer
antenna to evenly
distribute or scatter
microwaves into the
oven cavity
230VAC 2.7W.
Resistance 7 – 8k
Ω
Check for opens, shorts
or grounds
Check for locked rotor
(Power Off)
Check IO Board spade
connections X112
Check IO LED27
Check for Live supply
potential at IO X112
pins 1-2 & 3-4
VFD
(Motor Speed
Controller)
Takes 1PH AC supply
voltage and produces a
3PH DC square wave
frequency output.
3ph fan supply
protected individually
by 3x 5A ceramic on
board fuses.
Provides an DC, 3-
phase switched mode
drive to the AC
convection motor and
is controlled by a 0-10
VDC signal from the
relay board (IO). The
frequency output
allows the Main Blower
Motor to run at
variable speeds
1ph power supply.
Control Signal Voltage
10VDC output to the IO
Board, 2-10VDC return
to determine speed
percentage of
convection fan motor
(2-7.5VDC on 16A/13A
ovens). Output 3ph DC
square wave frequency
voltage
Check electrical
connection
Check IO Board
connections X113 &
X519
Check IO LED29
Check VFD LED
sequence. Check for
10VDC at pins P2
(Green) & P3 (Blue).
Check for 1-10VDC at
pins P1 (Red) & P3
(Blue)
Check Live supply
potential on VFD
Check for consistent
output voltage
between each phase
between Blue (U), Red
(V) & Yellow (W) (Digital
multi-meter should be
set to VAC to conduct
this check)