10. Other information - Cooling
105204
– WTS-300-E - V4.1 - 20.01.2022
Page 137
10.2 Different variants for cooling start delay
The control can be programmed to delay the start of the compressor after the cooling
mode has been triggered, to prevent a slight freezing of milk in the tank. This delay
takes place only in case of first milking after the cleaning.
A new manual activation of the cooling start delay can be triggered only by a long
pressing of the button “COOLING”.
To cover all the different system configurations possible, the WTS-300 offers a range
of variants for cooling start delay.
0.
no cooling start delay
Cooling starts immediately
1.
simple cooling start delay
Cooling starts after a set time.
2.
periodic cooling phases
Cooling starts in the form of periodic cooling phases at set intervals
before then switching over to temperature regulation.
3.
periodic cooling phases after switch-on delay
Cooling starts after a set time, in the form of pre-set periodic cooling
phases at set intervals before then switching over to temp. regulation.
4.
according to number of milk pump impulses
Cooling starts after the set number of milk pump impulses.
5.
periodic cooling phases after a number of milk pump impulses
Cooling starts after the set number of milk pump impulses in the form of
pre-set periodic cooling phases at set intervals before then switching over
to temperature regulation.
6.
Milk-volume-dependent cooling start delay
from start cooling [P50 - P 55]
Compressor starts according to the parameterized milk quantity in the tank
for the calculated running time, before switching to temperature control.
7.
Milk-volume-dependent cooling start delay
from start cleaning [P50 - P 55]
Compressor starts according to the parameterized milk quantity in the tank
for the calculated running time, before switching to temperature control.
Cooling start delay is
set using parameters
[P61 - P67].
Cooling immediately temperature-regulated
defined time
defined phases
defined time
defined phases
temperature-regulated
Milk pump impulses
Milk pump impulses
temperature-regulated
defined phases
Parameterized
milk quantity
temperature-regulated
calculated compressor
running- and break time
Parameterized
milk quantity
temperature-regulated
calculated compressor
running- and break time
temperature-regulated
temperature-regulated
temperature-regulated