Risk of poisoning!

Blocked air inlets can lead to the build-up of toxic Carbon
Monoxide.  Air inlet and outlet vents in the installation area should
therefore be kept open and clear from obstructions at all times.

When flue gas can be smelled:

1.

Turn off the equipment.

2.

Open doors and windows.

3.

Alert the heating company/installer.  

The smell of flue gas can also occur if the unit has not been used
for a long period of time. In this case, the condensate trap in the
unit must first be filled via the cleaning aperture of the flue gas
system.

Installation area

Unsuitable ambient conditions may damage the equipment. For
safe, reliable operation ensure that

the installation area is well ventilated and dust free for 
room air dependant operation,

the combustion air does not contain Halogen Hydrocarbons 
(such as in sprays, solvents, washing or cleaning products).

Working on the heating system

Improperly carried out work on the heating system can result in 
serious injury. Installation, commissioning, adjusting, servicing and
repairs must only be carried out by qualified personnel.
The unit must also only be opened by qualified personnel.

Fuel

The condensing boiler may only be operated with fuel oil
EL-1low sulphur (sulphur content max. 50 ppm) to DIN 51603-1.
Do not use additional additives.

For your safety

2

15

Chimney sweep function

Activate the symbol list by turning the dial knob and 
set cursor to chimney sweep symbol.  

Press 

key to activate chimney sweep function.

The function remains active for 25 minutes. 

The 3 larger numbers displayed show the current boiler
rating in kW.  

The 2 smaller numbers displayed show the current boiler
temperature. 

To exit the chimney sweep functions turn dial knob until
ESC is displayed and press  

key.

After approximately 90 seconds, the standard display
reappears. 

90 sec.

Содержание WTC-OW 15-A

Страница 1: ...ons Weishaupt Thermo Condens WTC OW 15 A Address of installer Max Weishaupt GmbH D 88475 Schwendi Tel 44 73 53 8 30 Fax 44 73 53 8 33 58 Print No 83189602 May 2008 Printed in Germany All rigths reserved 83189602 1 2008 05 ...

Страница 2: ...such as in sprays solvents washing or cleaning products Working on the heating system Improperly carried out work on the heating system can result in serious injury Installation commissioning adjusting servicing and repairs must only be carried out by qualified personnel The unit must also only be opened by qualified personnel Fuel The condensing boiler may only be operated with fuel oil EL 1low s...

Страница 3: ...lems occur 6 Operating the controller 7 Operating levels 8 Half yearly inspection 12 Monitoring the heat demand 14 Chimney sweep function 15 14 Monitoring the heat demand The heating water side volume flow is monitored by the WTC OW If for example the thermostatic valves close and the volume flow is less than 1 I min unnecessary burner starts are inhibited This saves energy both fuel and electrica...

Страница 4: ...ater these measures will have to be repeated when topping up Speak to your heating engineer Ask your heating engineer to show you how to correctly top up the system and how to operate the fittings If the indicator on the pressure gauge points to below 1 bar when the system is cold top it up with water until the indicator points to approx 1 5 bar Do not exceed the max pressure of 2 5 bar ATTENTION ...

Страница 5: ...ater refilling for chimney cleaning and maintenance 1 Switch off the condensing boiler 2 Display illumination ceases If the boiler is shut down for long periods the boiler water should be drained off to prevent frost damage ATTENTION 2 1 0 3 2 1 1 5 2 1 3 4 0 Bar 2 5 Standard settings 12 Half yearly inspection Is system pressure correct System warm System cold Depending on the type of system other...

Страница 6: ...g engineer 0 254 instructions f heat eng level Ch 6 3 6 What to do should problems occur reset 11 Adjust settings To avoid damage to the system do not reset the boiler more than twice If the boiler locks out for a third time 1 Note down message displayed 2 Request a service Possible fault displays Display Description Action required F21 no flame Check oil supply formation Further fault description...

Страница 7: ...0 C External sensor set point connected to B1 standby Room temp set point 7 Operating the controller 10 Standard display All operating elements are available once the front flap has been opened Dial knob This knob is used to change or adjust settings Right turn settings are increased reference marks are moved to the right or down Left turn settings are lowered reference marks are moved to the left...

Страница 8: ...oad active Burner lockout press reset key to restart Supply temperature or if flashing fault codes 9 Settings Setting of set points and display of additional system values Setting procedure Turn the knob to display the symbol list Turn the knob further to select the desired symbol The display mode appears when the cursor is moved to the right or left This same mode also appears if the enter key is...

Отзывы: