Weiser Smartcode 5 Скачать руководство пользователя страница 4

Z-Wave System Notes

This product is a security enabled Z-wave Plus product and must be used with a Security 
Enabled Z-Wave controller to be fully utilized. Z-Wave is a “Wireless mesh network,” and 
results may vary based on building construction and communication path.

To assure interoperability, each Z-Wave product must pass a stringent conformance test to 
assure that it meets the Z-Wave standard for complete compliance with all other devices and 
controls. The Z-Wave identity mark assures consumers, integrators, dealers and manufacturers 
that their products will reliably perform with any other Z-Wave device.  And, regardless of the 
vendor, always powered nodes may act as a repeater for Kwikset/Weiser/Baldwin products.

Z-Wave Configuration and Association Parameters are available on 
the SmartCode 5 Lever page at www.kwikset.com.

Removing the lock from the network

Follow your smart home system’s instructions 
to remove the lock from the network. When 
prompted by the system, press button A” on the 
lock interior once.

© 2016 Spectrum Brands, Inc.

1. 

Read all instructions in their entirety.

2.  Familiarize yourself with all warning and caution statements.

3.  Remind all family members of safety precautions.

4.  Protect your user codes and mastercode.

5.  Dispose of used batteries according to local laws and regulations.

  CAUTION: 

Prevent unauthorized entry. Since anyone with access to the back panel 

can change the user codes, you must restrict access to the back panel and routinely 
check the user codes to ensure they have not been altered without your knowledge. 
The use of a mastercode can help protect your system’s settings. 

  WARNING: 

This Manufacturer advises that no lock can provide complete security 

by itself.  This lock may be defeated by forcible or technical means, or evaded by 
entry elsewhere on the property.  No lock can substitute for caution, awareness of 
your environment, and common sense. Builder’s hardware is available in multiple 
performance grades to suit the application. In order to enhance security and reduce 
risk, you should consult a qualified locksmith or other security professional.

Important Safeguards

Alert

Reason

Solution

Keypad flashes red 1 time 
with 1 beep*

Door jammed while 
attempting to lock.

Manually re-lock door. If needed, 
reposition strike.

Keypad flashes red 3 times 
with 3 beeps*

Unsuccessful programming.

Attempt programming procedure 
again.

One incorrect code entered.

Re-enter code.

No user code  programmed.

Program at least one user code.

Keypad flashes red 10 
times with 10 beeps*

Low battery.

Replace batteries.

Lock beeps 2 times.

Programming timeout.

Attempt programming procedure 
again, making sure not to pause for 
more than 5 seconds.

Keypad flashes red 3 times.

Keypad flashes red 6 times 
with 6 beeps*.

Keypad flashes red 15 times 
with 15 beeps*

Three incorrect codes entered 
within one minute.

Re-enter code after 60-second keypad 
lockout.

*Beeping sound will only be heard if switch #3 is on.

Network Information

4 / 4

SmartCode at a Glance

Deleting a User Code

In order to delete a user code, you must override the code by adding a different user code in the same 
position. For example, if you want to delete the third code, add a different user code in position three. 

 Test the old user code to make sure it can no longer unlock the door.

If you cannot remember the user code position, you may wish to perform a factory reset to delete all 
codes associated with the lock.

Reference Guide

Exterior

Back 

panel

Program 

button

Status 

LED

Switches

Turnpiece

Interior (cover removed)

Switches and Status LED Colours

Troubleshooting

Switch

Function

1

Door lock status LED blinks every 6 
seconds

2

Lock automatically re-locks door 30 
seconds after unlocking. Disabled if no 
codes are programmed.

3

Audio

4

Not used.

Colour

Lock Status

Green

Unlocked

Amber

Locked

Red

Low battery

1   2   3   4

On

Switches

Status 

LED

Off

System Alerts

Factory Reset

Battery Replacement

A factory reset will delete all codes associated with the lock, 
and it will remove it from your smart home system.

If another lock is installed above the lever, remove the interior 
assembly when battery replacement is required.

Status 
LED

1  Remove 

battery pack.

2  Press and HOLD the Program 

button while reinserting 
the battery pack.

  Keep holding the button for 30 

seconds until the lock beeps 
and the status LED flashes red.

Keypad

Lock 
button

Keyway

SmartKey 

tool hole

Button “A”

Button “B”

3  Press the Program button 

once more. When the LED 
flashes green and you 
hear one beep, the lock 
has been reset.

4  Pair the lock with your smart home 

system, and add user codes to your lock. 

A complete Programming and Troubleshooting Guide is available on 

the SmartCode 5 Lever page at www.weiserlock.com.

Lock 
above 
lever

Mounting 
plate

Interior 
assembly

Battery 
pack

Содержание Smartcode 5

Страница 1: ...re to confirm that the hole in the door edge is 25 mm 1 in Measure to confirm that the door is between 35 and 44 mm 1 3 8 and 1 3 4 in thick A A C B D E B C D Is the semi circular hole of the latch centred in the door hole Is the door edge chiselled Install strike on the door frame Hold the latch in front of the door hole with the latch face flush against the door edge Adjust the latch face if nee...

Страница 2: ... exterior lever Secure mounting plate with supplied screws Secure exterior lever Install spindle Install interior lever The small bolt of the latch should not enter the strike hole If it enters the strike hole reposition strike A A B B C C D D cable goes over latch Do not install battery pack into interior assembly yet Lever handle faces away from the latch Tighten pre installed set screw If latch...

Страница 3: ...eping sound will only be heard if switch 3 on the lock interior is in the on positon See Switches and Status LED Colours on page 4 Mastercode For enhanced security a mastercode may be used when adding and deleting user codes For more information about the mastercode download the Programming and Troubleshooting Guide on the SmartCode 5 Lever page at www weiserlock com K K M H V 2x Tip You can press...

Страница 4: ...trike Keypad flashes red 3 times with 3 beeps Unsuccessful programming Attempt programming procedure again One incorrect code entered Re enter code No user code programmed Program at least one user code Keypad flashes red 10 times with 10 beeps Low battery Replace batteries Lock beeps 2 times Programming timeout Attempt programming procedure again making sure not to pause for more than 5 seconds K...

Страница 5: ...s 2 Configuration Parameters The Z Wave door lock module supports the use of the configuration command class to provide advanced configuration of the door lock over the Z Wave network This section describes the configuration parameters supported by the door lock 2 1 Configuration Parameters 1 through 30 Configuration parameters 1 through 30 are a one byte field used to set the type of user for the...

Страница 6: ... on the type of schedule created Example If a weekday schedule is created for a user code the associated user code type will change to Worker If a year day schedule is created for a user code the associated user code type will change to Guest If a user code is of type Worker or Guest it must have an enabled entry schedule to have access to the lock If a user code of type Worker or Guest does not h...

Страница 7: ...rogram the first four bytes of the SKU Setting parameter 34 will program the last 4 bytes of the SKU Most printable values are accepted for the set command When getting the SKU it must be done in two get commands one for each parameter The order of getting the SKU does not matter Getting parameter 33 will retrieve the first four bytes of the SKU Getting parameter 34 will retrieve the last 4 bytes ...

Страница 8: ...k and will remove it from your smart home system It will not remove any anti theft settings Please use the local reset procedure only when the primary controller is missing or inoperable 5 1 Local 1 Remove battery pack and press the program button a few times to discharge 2 Press and hold the program button 3 Replace the battery pack 4 Continue holding the program button for 30 seconds until the l...

Отзывы: