weinor PergoTex Type A Скачать руководство пользователя страница 10

Maintenance Instructions and Directions for Use 

 

 
 

Item number 115024-0000 

Subject to technical modifications 

Version 4 

12.07.2013 

Page 10/14 

 
 

PergoTex 

 

Maintenance and care instructions 

5.1 

Cleaning and maintenance work in the opening space of the PergoTex 

There is a risk of motorised sun protection units being activated unintentionally.  Always ensure 
that the PergoTex is completely switched off (e.g. by disconnecting the fuse) before performing 
maintenance and cleaning work (e.g. building cleaners).  
If awnings are operated by several users, a priority locking device must be activated (controlled 
interruption of the power supply from outside), making it impossible to open or retract the awning 
at all. 

5.2 Maintenance 

The safe and risk-free use of the Pergotex can only be guaranteed if the product is checked and 
serviced on a regular basis. The following maintenance requirements must be observed. 

  Inspect the PergoTex at regular intervals for signs of wear and tear or damage to the awning 

fabric and frame. Should you detect any damage, contact a specialist retailer or dealer or a 
suitable service company to carry out the repairs. Do not use units that are in need of repair. 

  Inspect the PergoTex at regular intervals for signs of wear and tear or damage to the cables 

and leads. Should you detect any damage, contact a specialist retailer or dealer or a suitable 
service company to carry out the repairs. 

Do not use units that are in need of repair. 
 
Even a low-maintenance product needs to be cared for. For this reason, please carry out the 
following maintenance and care tasks as required, once every spring, or whenever the awning 
has not been in use for a long time. Performing these tasks will extend the operating life of your 
awning system. Foliage and other foreign bodies as well as heavy dirt must be removed 
immediately

 

 

5.3 

Foliage and foreign bodies 

Foliage and other foreign bodies as well as heavy dirt 

  in the gutter, 

  on the fabric, etc. 

must be removed immediately. 
 
Rainwater outlet holes 

  in the posts 

must be kept unblocked at all times to ensure that water can drain off.  

Содержание PergoTex Type A

Страница 1: ...technical modifications Version 4 12 07 2013 Page 1 14 PergoTex PergoTex Type A Folding patio roof with electric motor ENGLISH Important guidelines for the end user Please read these instructions and...

Страница 2: ...in winds 7 3 3 Explanation of wind resistance classes 7 3 4 Use in rain 8 3 5 Automatic controls 8 3 6 General notes on the fabric 8 4 Specific safety notes 9 4 1 Checking and monitoring the PergoTex...

Страница 3: ...quality from the very beginning 1 1 Depiction 1 1 1 Warnings The warnings differentiate between personal injury and damage to property The signal word Danger is used for personal injury and Caution f...

Страница 4: ...80x60 Transom cap 36x60 4 5 End cap for cover Wall connection capping 19 20 Transom cap 80x60 Side channel 6 Angle bracket locking bar 21 Trapezium shaped sheeting 7 Guttering 22 Fabric roller 8 end...

Страница 5: ...rain The PergoTex can be fitted to any angle of pitch ranging between 8 and 45 depending on the projection and installation height of the awning When the awning is closed the protective roof extensiv...

Страница 6: ...is supplied as standard with the PergoTex has been designed to run for a maximum of four minutes at a time If the running time is exceeded e g by frequently opening and retracting the awning the inte...

Страница 7: ...This may deviate from the wind resistance class stated by the manufacturer 3 3 Explanation of wind resistance classes Wind force acc to the Beaufort scale Description of wind force Effect on land 0 Ca...

Страница 8: ...A PergoTex must never be left unattended when open The automatic controls may fail under extreme conditions e g power failures defects sudden storms There is a risk that the PergoTex could be damaged...

Страница 9: ...r Monitor the PergoTex when it opens and retracts and keep people clear of the area until the PergoTex has fully opened and retracted The assembly work may only be performed by trained personnel Guide...

Страница 10: ...for signs of wear and tear or damage to the awning fabric and frame Should you detect any damage contact a specialist retailer or dealer or a suitable service company to carry out the repairs Do not u...

Страница 11: ...the work for you This is a good way to protect the aluminium parts and their surface from being corroded by salty water 5 5 2 In non saltwater areas Clean the aluminium parts at least once a year and...

Страница 12: ...ns the PVC coated product must be rinsed with abundant water in order to remove every trace of detergent The last rinse has to be carried out with a diluted 2 solution of sodium hypochlorite before st...

Страница 13: ...rson is your local specialist and will gladly provide you with swift professional advice To help you troubleshoot a few errors are listed below 6 1 Troubleshooting Error Cause Remedy System not runnin...

Страница 14: ...s Glasoase conservatories Your weinor partner is an experienced specialist who will gladly provide you with advice on everything from planning to realising your product They will help you turn your pa...

Отзывы: