Specific safety notes 

 

 

Personal injury 

Risk of personal injury due to improper use of the weinor PergoTex II. 

 

Please read and observe the specific safety notes contained in this section. 

 

4.1  Checking and monitoring the weinor PergoTex II 

For personal safety, it is important that these safety notes are complied with and kept in a safe 

place.  

  The performance of a product depends on how it is assembled and installed. 

  Check the awning system for signs of wear or damage. 

  On motorised systems, check the electrical leads for damage. 

  Do not use units that are in need of repair. 

  The repair work may only be performed by trained personnel. 

 

Guidelines for systems with automatic controls 

  When performing maintenance or installation work, disconnect the weinor PergoTex II from 

the power supply.  

 

4.2  Operation 

It must be ensured that no children or people unable to properly assess the risks of improper or 

incorrect use are able to operate the weinor PergoTex II. 

Remote controls must be kept out of reach of children. 

The setting and operating instructions supplied separately by the manufacturer of the motor, 

switches and controls must also be observed. 

 

4.3  Disassembly and disposal 

Always secure the awning system before dismantling and disposing of it. A suitably qualified 

company should be engaged to perform this task. 

 

 

 

 

DANGER 

Содержание PergoTex II

Страница 1: ...ctions and Directions for Use Version 7 2020 05 08 We reserve the right to make technical changes Item number 118702 0000 Page 1 16 Pergola awning with electric drive ENGLISH Important guidelines for...

Страница 2: ...Use in winds 8 3 3 Explanation of Beaufort classes 8 3 4 Use in rain 9 3 5 Important guidelines for the winter season 9 3 6 Automatic controls 9 3 7 General notes on the fabric 9 4 Specific safety no...

Страница 3: ...tructions weinor quality from the very beginning 1 1 Depiction 1 1 1 Warnings The warnings differentiate between personal injury and damage to property The signal word Danger is used for personal inju...

Страница 4: ...the right to make technical changes Item number 118702 0000 Page 4 16 2 Product description 2 1 Schematic diagram of the weinor PergoTex II Basic LED Figure 1 Schematic diagram of the weinor PergoTex...

Страница 5: ...cal changes Item number 118702 0000 Page 5 16 2 2 Schematic diagram of the weinor PergoTex II LED Figure 2 Schematic diagram of the weinor PergoTex II Basic LED 1 Post 6 Transom 80x60 mm 2 Guttering 7...

Страница 6: ...tallation height of the awning However optimum rain drain can only be guaranteed with a pitch of more than 8 The wind resistance class 3 to wind strength 6 is applicable for the weinor PergoTex II Whe...

Страница 7: ...e wait until the motor has cooled down approx 15 20 minutes depending on the outside temperature and is ready for operation again If your weinor PergoTex II is fitted with a sun wind or rain controlle...

Страница 8: ...ke rises vertically 1 Light air Barely noticeable smoke drift indicates wind direction still wind vanes 2 Light breeze Leaves rustle wind felt on face 3 Gentle breeze Leaves and small twigs constantly...

Страница 9: ...valanching snow 3 6 Automatic controls A weinor PergoTex II must never be left unattended when open The automatic controls may fail under extreme conditions e g power failures defects sudden storms Th...

Страница 10: ...n motorised systems check the electrical leads for damage Do not use units that are in need of repair The repair work may only be performed by trained personnel Guidelines for systems with automatic c...

Страница 11: ...for a long time Performing these tasks will extend the operating life of your awning system Foliage and other foreign bodies as well as heavy dirt must be removed immediately 5 3 Foliage and foreign...

Страница 12: ...increased absorption of dirt Therefore clean the PVC coated fabric on a regular basis and or in case of excessive pollution Product damage due to improper cleaning of the PVC fabrics Adhere to the fol...

Страница 13: ...aluminium profiles Check that all rubber gaskets and permanently elastic seals are correctly positioned Check the grouting and repair if necessary Check all gaskets seals etc between the PergoTex II...

Страница 14: ...rsonnel only Wait approx 15 to 20 minutes until the motor has cooled down Squeaking Bearing surfaces not lubricated Maintenance and care fitter Light off No power Establish a power supply voltage Noti...

Страница 15: ...PergoTex II PergoTex II LED Maintenance Instructions and Directions for Use Version 7 2020 05 08 We reserve the right to make technical changes Item number 118702 0000 Page 15 16...

Страница 16: ...Directions for Use Version 7 2020 05 08 We reserve the right to make technical changes Item number 118702 0000 Page 16 16 weinor GmbH Co KG Mathias Br ggen Stra e 110 50829 Cologne Germany www weinor...

Отзывы: