Страница 1: ...Easy Automatic external defibrillator Device nos 1000 to 1340 from device no 1341 with ILCOR 2005 Service and Repair instructions MEDUCORE Easy with Battery Pack MEDUCORE Easy with Rechargeable Batte...
Страница 2: ...21 6 3 Testing devices 21 6 4 Replace SRC sticker 21 6 5 Documentation 21 7 Malfunctions and Rectification 22 8 Repair information and repair instructions 24 8 1 General 24 8 2 Tools and facilities 2...
Страница 3: ...ying out repairs as shown in the service and repair manual In case of warranty claims all devices are to be sent to WEINMANN In order to handle warranty or goodwill requests we will require you to sub...
Страница 4: ...trode plug 9 Carrying handle 10 Shock key Underside of device 11 Display Shock preperation 17 Battery Pack Rechargeable Battery Pack optional 16 Self sticking defibrillation electrodes 19 Emergency se...
Страница 5: ...s for the delivery of an electric shock The delivery of a shock is carried out directly by the user after the device has prompted to do so Only use the device MEDUCORE Easy for the purposes described...
Страница 6: ...activated metronome function gives off an acoustic metronome signal at a frequency of 100 beats per minute during the HLR pause Carry out the cardiac massage in rhythm with audible signal tone After...
Страница 7: ...should carry out a heart lung revival Application documentation The MEDUCORE Easy saves ECG and event data The data could later be used e g in the follow up of treatment For this use the documentatio...
Страница 8: ...his can otherwise lead to damage of the device and consequently endanger users and patients The MEDUCORE Easy can be kept properly clean by simply wiping to disinfect Please observe the users instruct...
Страница 9: ...es of such errors and recommended countermeasures by referring to chapter 7 Malfunctions and Rectification on page 22 We recommend that you generally keep the following ready for use Emergency Set WM...
Страница 10: ...ings cannot be modified 4 3 Entering the device data Enter the serial number of the device Device No and the manufacturing date into the test records 4 4 Checking the devices self testing 1 Insert rec...
Страница 11: ...input shock button and shock output Preparation of the MEDUCORE Easy 1 Connect the rechargeable battery adapter cur rent measuring device and rechargeable battery or battery pack as illustrated 2 Inst...
Страница 12: ...e Press the flashing shock key activate this Requirement The shock is triggered by activation of the shock button The shock is given The device clearly gives the spoken message Shock was delivered The...
Страница 13: ...illator tester Sinus EKG Request All of the LEDs in the green pentagon light up 4 8 Checking the info button and reading contact 1 While the green pentagon is lit up press the info button Request The...
Страница 14: ...is correctly attached easy to open and closes firmly Functions open close switch on are ok Inner part The socket for the electrode plug is free from dirt Rechargeable Battery Pack Completely charged...
Страница 15: ...ance and SRC stickers are affixed correctly SRC sticker applies only to Germany If repairs have been carried out then you should replace the stickers with new ones 4 13 Preparing a device for dispatch...
Страница 16: ...Set the date and time with the help of the EasyView see chapter Operation in the operat ing instructions for the PC Software EasyView WM 16880 After exchanging the printed circuit board if no customer...
Страница 17: ...Checking the device 17 4 14 Documentation Note down the points 4 3 to 4 12 as well as the test date and tester number in the test records...
Страница 18: ...the Battery Rechargeable Battery see chapter 5 2 page 18 Replace internal battery see chapter 8 8 page 29 Final check in accordance with test directive WM 40006 see chapter 4 page 9 Renew maintenance...
Страница 19: ...checks the charging level Offer your customer a new Battery Pack Recommend that your customer replaces the Battery Pack as soon as possible Capacity is 8 Inform your customer about the charging level...
Страница 20: ...ase contact a licensed and certified electronic waste recycler Names and addresses can be obtained from your Environmental Officer or municipal authorities Disposal of batteries Do not dispose of spen...
Страница 21: ...an additional description of the required steps to be taken 6 3 Testing devices Additional to the named testing devices described in chapter 4 1 you will need SRC protocol see WM 40007f page 2 on page...
Страница 22: ...low Battery power levels are low Finish off current treatment and then replace batteries see Chapter Energy Supply in the operating instructions MEDUCORE Easy The red LED will light up flashing when...
Страница 23: ...ce and check connections Chapter 8 3 Page 25 Main circuit board defective Open up device and exchange the main circuit board Chapter 8 9 Page 30 Shocks can not be delivered in spite of flashing shock...
Страница 24: ...ing repairs After every repair a maintenance check must be performed see 4 Checking the device on page 9 When replacing components or single parts use only genuine WEINMANN Parts When ordering the dev...
Страница 25: ...MEDUCORE Easy 2 Lie the MEDUCORE Easy with the red lid facing down on a non slip surface 3 Remove the sealing plugs 33 4 Loosen and remove the ten screws 30 5 Take the MEDUCORE Easy in both hands and...
Страница 26: ...he front of the device The capacitor is very slightly charged The display will now show for example 0 07 Upon releasing the button the display must slowly return to 0 00 Danger Risk of electric shock...
Страница 27: ...5 Pull the loudspeaker cable from the printed circuit board 6 Pull the red cable plug out of the printed circuit board 7 Pull the capacitor out of the lower encasing part and place it carefully on th...
Страница 28: ...circuit board 5 Press the capacitor into the compartment of the lower encasing part Guide the cable in through the slit 6 Plug the cables for capacitor 27 onto the board Ensure that polarity is corre...
Страница 29: ...he printed circuit board Make sure that the polarity is correct see the labelling on the printed circuit board and on the capacitor If the cables are mixed up then the upper and lower device parts wil...
Страница 30: ...the capacitor onto the printed circuit board Make sure that insulation mats 28 are lying between the capacitor and the main circuit board 3 Plug the capacitor cable 27 into the printed circuit board M...
Страница 31: ...he device configuration The number will now be stored in MEDUCORE Easy If a 4 digit serial number is entered the system will automatically pad it out to 5 digits by adding a leading 0 If the serial nu...
Страница 32: ...circuit board 4 Plug the new cable in its place 5 Place the cable lug and spring washer onto the screw and screw the nut onto it Make sure that the order is correct 6 Close the device see Chapter 8 6...
Страница 33: ...rged see Chapter 8 3 Page 25 1 Discharge capacitor and open up the device see Chapter 8 3 Page 25 2 Remove the main circuit board see Chapter 8 9 Page 30 3 Install the main circuit board into a new up...
Страница 34: ...07 WM 40517 WM 40527 WM 40667 WM 40677 WM 40687 WM 40558 16 Defibrillation electrodes DE GB Defibrillation electrodes FR Defibrillation electrodes IT Defibrillation electrodes TH Defibrillation electr...
Страница 35: ...rd RU new Main circuit board RU replacement Main circuit board PL new Main circuit board PL replacement Main circuit board NL new Main circuit board NL replacement Main circuit board ES new Main circu...
Страница 36: ...M 40167 33 Sealing plug WM 40158 34 Battery 3 V WM 40089 35 Handle WM 40103 36 Handle sealing WM 40186 37 Cylinder head screw M8x30 DIN EN ISO 4762 ST ZN WM 50607 38 Flexible handle including attachin...
Страница 37: ...MEDUCORE Easy JA TH Instructions for use MEDUCORE Easy PL RU Instructions for use MEDUCORE Easy IS FI Instructions for use MEDUCORE Easy TR GR Instructions for use MEDUCORE Easy ID CN Instructions for...
Страница 38: ...Battery Adapter WM 40008 Test line MEDUCORE Easy WM 40454 10 3 Software EasyView Service PC software 10 4 Testing devices Multimeter measuring range up to 20 A Defi tester ECG graphs Sinusoidal rhyth...
Страница 39: ...ss IEC 529 IPX4 protected against sprayed water Vibration and knock DIN EN 1789 1999 Free fall EN 60601 1 1996 Electromagnetic compatibility EN 60601 1 2 2001 EN 55011 1998 A1 EN 55014 1 2000 A1 EN 61...
Страница 40: ...Stand by Time up to 5 years 4 years Maximum charging time 4 h Maximum charging power 1 2 A Transport Storage Temperature range Air humidity 40 C to 85 C 0 to 90 Service life 300 full charges Battery...
Страница 41: ...ay affect or prevent the proper identification of arrhythmias It is thus possible that not all defibrillatable rhythms will be identified and shock output from the device is not recommended under cert...
Страница 42: ...high Energy protocol constant rising Metronome function on off Data management Recommended safe distance between mobile HF telecommunications devices e g mobile telephones and the MEDUCORE Easy Nomin...
Страница 43: ...e V1 2 2 WM 40192a 08 12 2006 Adjusting the EasyView software for the extended flash memory erase time on the WM 40130 PCB revision by the manufacturer V 1 2 3 WM 40192b 21 02 2007 Adjusting the EasyV...
Страница 44: ...___________ __________________ Date Signature Device type MEDUCORE Easy Order No ________________________ Company _____________ __________________ Date Signature Date of manufacture ________________ S...
Страница 45: ...Manufacturer s designation Operator Safety related check Due date 2 years Scope Verify that the equipment is complete Visual inspection for mechanical damage Test of system components Safety related c...
Страница 46: ...y and capacitor discharge LEDs belonging to the progress displays pentagon triangle charge and shock button are all lighting correctly The capacitor is discharged if the shock is not delivered 8 Check...
Страница 47: ......
Страница 48: ...weg 40 D 22525 Hamburg T 49 0 40 5 47 02 0 F 49 0 40 5 47 02 461 E info weinmann de www weinmann de Center for Production Logistics Service Weinmann Ger te f r Medizin GmbH Co KG Siebenst cken 14 D 24...