Weil-McLain RIELLO 40 BF UltraOil 800060000-Brn-PO Rie BF5 Скачать руководство пользователя страница 18

3398

15

GB

BURNER START- UP FORM *

35 Pond Park Rd.

Hingham, MA 02043

Phone: 781-749-8292

Toll Free: 800-992-7637

Fax: 781-740-2069

2165 Meadowpine Blvd.

Mississauga,On L5H 3R2

Phone: 905-542-0303           

Toll Free: 800-387-3898

Fax: 905-542-1525

Burner S/N. or Model:

Installer name:

Company:

Address:

Phone:

Owner Name:

Address:

Phone:

Appliance:

Installation date:

Fax:

E-mail:

Nozzle info:

Pump pressure:

Turbolator setting:

Draft overfire:

Draft breech:

Air setting:

CO

2

:

CO:

O

2

:

Smoke density:

(Bacharach)

Single line:

Two lines:

Burner Start-up Info (OIL)

*

 This form was designed and provided in the installation manual for reference and also for providing tech-

nical information which can be faxed or mailed to our technical hot-line coordinator when technical assis-
tance is required. Please complete this form, fax it or mail it at the address/fax above, or send an e-mail
with the information listed below to: [email protected]

Содержание RIELLO 40 BF UltraOil 800060000-Brn-PO Rie BF5

Страница 1: ...nd wiring of the burner Please read carefully before attempting final installation This manual is to remain with the final installation designation It is the installer s responsibility to en sure that...

Страница 2: ...roughly cleaned prior to installing a new filter cartridge DRAFT Follow the instructions furnished with the heating appliance The pressure in the combustion area should be kept as close to zero as pos...

Страница 3: ...SEMBLY 5 ELECTRODE SETTING 5 NOZZLE PLACEMENT 5 TURBULATOR SETTING 5 OIL LINE CONNECTIONS 6 Single line Gravity feed system 6 NPTF NPT pipe adapter 7 Two line Lift system 7 PUMP PURGE 8 Single line Gr...

Страница 4: ...ure A BI week of manufacture 8511111 Burner product code 00025 Increment of 1 for each burner pro duced specific to product code reset to zero each January 1st Quantity Description Code 1 Burner with...

Страница 5: ...nition transformer 8kV 16mA Model A B C D E F BF3 Inches 9 13 16 11 1 4 7 1 2 3 1 2 4 5 8 8 21 32 mm 249 286 193 89 117 220 BF5 Inches 9 13 16 11 1 2 7 1 2 3 1 2 6 5 16 6 13 16 mm 249 292 193 89 160 1...

Страница 6: ...ctrical connector 2 Earth ground conductor terminal Green wire 3 Hot conductor terminal Black wire 4 Neutral conductor terminal White wire Using the appropriate diagram below make electrical connec ti...

Страница 7: ...or 4 AIRPRESSURE SWITCH 10 BLUE BLUE BLUE REMOTE SENSING OF SAFETY LOCKOUT The SAFETY SWITCH in the 530SE CONTROL BOX is equipped with a contact allowing remote sensing of burner lockout The electrica...

Страница 8: ...ed NOZZLE PLACEMENT Remove the NOZZLE ADAPTER 2 from the DRAWER ASSEMBLY by loosening the SCREW 1 Insert the proper NOZZLE into the NOZZLE ADAPTER and tighten securely Do not over tighten Replace adap...

Страница 9: ...tions No changes to the oil pump are required for use in single line applications NOTE If the pump cover 1 is removed for any reason be sure the O ring 2 is properly seated in the pump cover 1 before...

Страница 10: ...the bottom of the oil tank The return line should terminate near the top of the oil tank B Suction and return lines should be sized in accordance with local codes and both should extend to the same d...

Страница 11: ...ir tube cover Shines a light source on the photocell now visible where the air tube cover was removed return power to the burner and activate the burner With the light source in place the burner will...

Страница 12: ...reset 1 BF5 Factory preset 1 BF5 Factory preset 1 Boiler UO3 UO3 UO4 UO5 Input GPH 0 8 1 0 1 2 1 4 Nozzle Delavan 65 X 70 B 85 X 60 B 1 00 X 70 B 1 10 X 70 B Pump Pressure PSI 150 145 145 160 0 1 3 4...

Страница 13: ...3398 10 GB BURNER START UP CYCLE Normal Lock out due to light failure Thermostat Motor Ignition transformer Valve Flame Lock out lamp 12sec 12sec 5sec D7526 2min...

Страница 14: ...l pressure Ignition electrodes shorted cracked porcelain Burner motor not up to speed Excessive draft over fire Defective control box Replace Burner Fires Cycles On Off In Quick Succession 483SE Only...

Страница 15: ...vent condensation or corrosion of intake air venting F Used approved type of intake air vacuum breaker and to be installed in the same room and the burner for the event of intake air source being bloc...

Страница 16: ...13 3398 EXPLODED SPARE PARTS LIST...

Страница 17: ...CONTROL SUB BASE 21 3001157 C7001029 PRIMARY CONTROL 530SE C 22 3002280 PHOTOCELL 23 3008078 BURNER FRONT PLATE 23 3008079 BURNER FRONT PLATE 24 3000932 MOVEABLE FLANGE 25 3020248 MOUNTING GASKET 26 3...

Страница 18: ...Nozzle info Pump pressure Turbolator setting Draft overfire Draft breech Air setting CO2 CO O2 Smoke density Bacharach Single line Two lines Burner Start up Info OIL This form was designed and provide...

Страница 19: ...474 3556 35 Pond Park Road Hingham MA 02043 Phone 781 749 8292 Toll Free 800 992 7637 Fax 781 740 2069 www riellousa com 2165 Meadowpine Blvd Mississauga ON L5N 6H6 Phone 905 542 0303 Toll Free 800 3...

Отзывы: