GOLD
WTGO
OIL-FIRED NATURAL DRAFT WATER BOILER — SERIES 3 —
Boiler Manual
HOMEOWNER and SERVICE TECHNICIAN — read and follow completely.
Operation
WTGO
(see Figure 1)
1. If burner does not fire, check for:
•
Service switch on boiler or additional switches turned off.
•
Fuses or breaker switch tripped.
•
Thermostat set below room temperature.
•
Fuel valves turned off.
•
Not enough oil in tank to supply burner.
Figure 1
WTGO Boilers
2. Correct problems found in step #1. If burner does not fire,
press reset button on burner primary control only once.
Repeated presses will deposit oil in combustion chamber.
Burner must never be fired when oil is in combus-
tion chamber. Immediately call qualified service
technician.
3. If burner still does not fire, call qualified service technician.
1
Burner disconnect plug
2
Service switch on boiler
3
Water relief valve
4
Temperature-pressure gauge
5
Circulator
6
Combination limit control,
tankless heater control and
low water cut-off (located in
tankless heater plate)
7
Reset button on burner
primary control
8
Burner primary contro
l