![Weil-McLain GOLD CGt SERIES Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/weil-mclain/gold-cgt-series/gold-cgt-series_manual_952721025.webp)
Part Number
550-110-290/0107
5
GOLD CGt Gas-Fired Water Boiler — Boiler Manual
1
Boiler isolation (balancing) valves
2
Flow/check valve
3
System or zone circulator
4
System temperature gauges
5
Zone valve
6
Drain valve
7
System temperature valves (see instruc-
tions on page 4 for adjusting valves)
8
Blend temperature gauge
9
Relief valve
10
Automatic air vent
11
Fill valve
12
Diaphragm-type or bladder-type expansion tank, if used
13
Air separator and automatic vent, if used (Note that the fill valve
must always be connected to the expansion tank, at item 11.)
Figure 20
By-pass piping
Zoning with circulators
Figure 21
By-pass piping
Zoning with zone valves
Piping — low temperature systems
(continued)