Part number 550-141-887/0800
23
AHE
Series 4 Direct Vent Wall-Mounted Boilers
— Boiler Manual
10b
Operation — wiring diagram
Figure 18
N
G
Notes:
SERVICE
SWITCH
H
Items not provided
Table G: Gas valve terminals and anticipator settings
Honeywell VR8205A
Robertshaw 7200DER
White-Rodgers 36E
2
2
MV
MV
1
1
Gas valve
"A"
"B"
Anticipator
amps
0.6
0.7
0.7
Electrical shock hazard — can cause severe injur
y or
death. Disconnect power before installing or ser
vicing.
SERVICE
SWITCH
THERMOST
A
T
THERMOST
A
T
120 V
AC
120 V
AC
24 V
AC
24 V
AC
Control module
lo
w v
oltage
section
CONTR
OL
MODULE
120
V
A
C
SECTION
P
ower
G
T
stat–Circ
Limit
P
ress switch
Flame
Flame
sensor
ROLLOUT
TFE
ROLLOUT
TFE
INDUCER MOTORINDUCER MOTOR
CIRCULA
TOR
CIRCULA
TOR
W
A
TER TEMP
LIMIT SWITCH
W
A
TER TEMP
LIMIT SWITCH
GAS V
AL
VE
GAS V
AL
VE
AIR PRESSURE
SWITCH
AIR PRESSURE
SWITCH
HOT SURF
ACE
IGNITER
HOT SURF
ACE
IGNITER
HIGH
VOL
TAGE
HIGH
VOL
TAGE
120 V
A
C
See T
able G
SchematicWir
ing Diagra
m
LadderWir
ing Diagra
m
"A""A"
"B""B"
ROLLOUT TFE
BK
BK
Y
YY
Y
Y
Y
Y
W
BK
JUNCTION BOX
W
A
TER
TEMPERA
TURE
LIMIT SWITCH
BLOCK
TEMPERA
TURE
SWITCH
IGNITION MODULE
THERMOST
A
T
OR END SWITCH
(Note 3)
PRESSURE SWITCH
"A"
"B"
GAS V
AL
VE
TERMINAL BLOCK
(see T
able G)
Hot sur
face igniter
BK
G
G
W
WW
W
BK
BK
R
R
Resistor
R
R
R
R
W
BR
BR
G
BK
BK
G
BK
C
NO
NC
BL
BL
W
CIRCULA
TOR
WIRE NUTS
EQUIPMENT
GROUND
INDUCER
MOTOR
TRANSFORMER
P
a
rt
Number
550-223-787/0800
AHE
Ser
ies 4
• Hot surf
ace ignition
• Natur
al or propane gas
• F
o
rced hot w
a
ter
Legend
120 V
AC FACTOR
Y WIRING
LOW VOLTAGE FACTOR
Y WIRING
120 V
AC FIELD WIRING
LOW VOLTAGE FIELD WIRING
Plug
-in connectors
Red
White
BL
BL
EQUIPMENT
GROUND
N
G
H
(note 6)
(note 10)
(note 3)
(note 8)
(note 7)
BLOCK
TEMPERA
TURE SWITCH
R
R
R
R
BK
BK
G
WW
G
W
BK
G
GG
BK
BK
A United Dominion Compan
y
W
eil-McLain • 500 Blaine St. • Michigan City
, IN 46360-2388
1.All wiring must be installed in accordance with:
A.U.S.A. — N.E.C. And any other national, state, or local code
requirements.
B.Canada — C.S.A. C22.1 C.E.C. Part 1 and any other national,
provincial, or local code requirements.
2.If any of the original wire as supplied with the appliance must be
replaced, use minimum 105 °C wire or equivalent. Exception: Wires to
Rollout TFE must be 200 °C or equivalent.
3.Thermostat anticipator setting (single zone) — see T
able G for
anticipator setting, depending on which gas valve is installed in boiler
.
4.For multiple zoning, use either zone valves or cir
culators.
Refer to the
component manufacturer's instructions and this manual for application
and wiring suggestions.
5.Refer to control component instructions packed with the boiler for
application information.
6.All contacts shown without power applied.
7.Connector and status light locations may var
y.
8.The control module is polarity-sensitive to the incoming 120 V
AC
power
. If polarity is reversed, control will flash the POWER light when
powered and will not cycle boiler
.