上海维宏电子科技股份有限公司
SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO., LTD
.
11
/
116
Different control systems require different settings.
Set Drive Parameters in Non-bus Control Systems
Set Drive Parameters in Bus Control Systems
3.4.1 Set Drive Parameters in Non-bus Control Systems
Different servo drive parameters need to be set in different follow control modes:
Set Drive Parameters in Position Loop Control Mode
Set Drive Parameters in Velocity Loop Control Mode
If you are using a non-WEIHONG drive (WISE):
Ensure that the servo drive SON signal is active low (ON when connected to GND
of a 24V power supply).
If the servo drive is active low when it works normally, set the polarity of the drive
alarm input port to
NC
. If the servo drive is active low when it reports an alarm, set
the polarity of the drive alarm input port to
NO
.
Set the drive
pulse signal type
parameter to
pulse + direction
.
Ensure that the servo drive does not have an external emergency stop signal input
port. If it does, check the signal logic.
Ensure that the terminal board is connected to a 24V power supply before drive trial
run.
3.4.1.1 Set Drive Parameters in Position Loop Control Mode
Test parameter settings in position loop control mode as shown below:
WISE
Yaskawa Σ-
Ⅱ
Yaskawa Σ-
Ⅱ
Σ-
Ⅴ
/ Σ-7
Panasonic MINAS A4
Panasonic MINAS A5
Fuji FALDIC-
β
Fuji ALPHA 5
Delta ASDA-A
Delta ASDA-A2
Delta ASDA-B
Delta ASDA-B2
3.4.1.1.1 WISE
The parameters and descriptions are shown below:
Pr001 Control mode selection
o
Description: Control mode setting
o
Unit: -
o
Range
1: Position control mode
2: Velocity control mode
o
Value: 1
Pr528 LED initial state
o
Description: Pulse detection is used in WEIHONG control systems to check
to see if correct pulses are sent and determine if there is electric interference.
o
Unit: -
o
Range: -
o
Value: 6 Command pulse sum
Pr008 Number of command pulses per motor turn
Содержание LS6000M
Страница 6: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 3 116 1 3 Shortcut Keys The shortcut keys are as follows...
Страница 63: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 60 116 Lambda NE The port definitions are shown below...
Страница 69: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 66 116 5 2 5 MAX Fiber Laser The wiring diagram is shown below...
Страница 75: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 72 116 With brake lines 50P HD plug...
Страница 76: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 73 116 Without brake lines 50P HD plug...
Страница 78: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 75 116 One to two...
Страница 81: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 78 116 Fuji alpha5 plus axis X Y1 Y2...
Страница 83: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 80 116 Delta ASDA B...
Страница 84: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 81 116 Delta ASDA B one to two...
Страница 86: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 83 116 MR JE with brake cable...
Страница 87: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 84 116...
Страница 91: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 88 116 ESDA...
Страница 93: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 90 116 R series...
Страница 96: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 93 116 With brake lines 50P HD plug...
Страница 97: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 94 116 Without brake lines 44P interface...
Страница 105: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 102 116 Delta ASDA B2...
Страница 112: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 109 116 The button definitions are shown below...
Страница 114: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 111 116 The button definitions are shown below...
Страница 115: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 112 116...
Страница 117: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 114 116...