3.
Set parameters.
Move
It sets the moving distance of the machine.
Sample
It sets how many times that CCD shoots and acquires sample or characteristic points.
Interval
It sets the sampling interval distance.
Sampling delay
It sets the delay time before each sampling.
4.
Click
Execute
.
The machine automatically moves and conducts measurement.
(Optional) Click
Stop
to suspend the sampling process.
5.
Click
History Record
after the measurement finishes.
Magnification factor and CCD-Spindle angle of each measurement will be shown
in history records.
6.
Click
OK
.
Average value of measuring results will be updated as camera parameter.
For repeated measurement, please clear the history record before next
measurement, to avoid possible interference.
Example
Following is parameter setting suggestion.
Moving distance: 22mm
Sampling times: 10
Sampling distance: 20mm
Sampling delay: 300
Setting CCD-spindle Offset
CCD-spindle offset refers to the distance between the camera and the spindle. It
includes X-axis offset and Y-axis offset.
Steps
1.
Drill a hole on the workpiece surface.
2.
Click
Record Pos 1
. The system records the current machine coordinates.
WEIHONG ELECTRONIC TECHNOLOGY CO., LTD.
- 16 -