Weidmüller IE-SW-EL24-24TX Скачать руководство пользователя страница 2

 

 

 

 

V1.0 / 2020-10-29 

8.  Wiring Redundant Power Inputs and Power Fault 

Relay 

The switch supports redundant power supply inputs and provides a power fault relay 
which can be used for alarming in case of interruption of Power 1 or Power 2 on the 6-pin 
terminal block. Refer to illustration below for correct wiring. 
 

 

 Warning / Avertissement 

 Take into consideration the following guidelines before wiring the device 

o

 Tenez compte des directrices suivantes avant de câbler l’appareil. 

  Terminal block is mating with Plug and suitable for 12-24AWG. Torque 

value 4.5 lb-in. 

o

 Le bornier est compatible avec les connecteurs et convient pour 12-

24AWG. Valeur de couple 4,5 lb-in. 

  The temperature rating of the input connection cable should higher than 

105°C. 

o

 La température de service nominale du câble d’entrée doit être 

supérieure à 105 °C. 

  Supplied by SELV source evaluated by UL 61010-1 or 61010-2-201 

power supply only. 

o

 Fourni par la source SELV évaluée uniquement par l'alimentation UL 

61010-1 or 61010-2-201. 

 
 

 

Note about behavior of power failure relay: 

  Relay contact is closed if the device is powered-off. 

  Relay contact is open if the device is powered by PWR1 

and

 PWR2  

  Relay contact is closed if device is powered 

either

 by PWR1 

or

 PWR2  

 

9.  Communication Connections 

Switch 

IE-SW-EL24-24TX

 is equipped with following communication interfaces: 

 
24 x 

10/100Base-T(X) ports  

Please only use cables suitable for the respective type of communication and ensure that 
signals are protected from possible interference. 

9.1 

10/100Base T(X) RJ45 Ports 

The 10/100BaseT(X) ports located on Ethernet Switch’s front panel are used to connect 
to Ethernet-enabled devices. Below we show pinouts for both MDI (NIC-type) ports and 
MDI-X (HUB/Switch-type) ports. Auto MDI-X ensures that both wiring-schemes are 
supported (Automatic crossover function). 

 

 

10/100Base T(X) RJ45 Pinouts 

MDI Port Pinouts 

MDI-X Port Pinouts 

8-pin RJ45 

Pin 

Signal 

Pin 

Signal 

 

Tx+ 

Rx+ 

Tx- 

Rx- 

Rx+ 

Tx+ 

Rx- 

Tx- 

 
 

 

Note about possible loss of data packages in case of “Duplex mismatching” 

If the switch’s auto-negotiation port is connected to a non-negotiating device, 
then the switch will set its port transmission speed same as the connected 
device but is unable to correctly detect the duplex mode. 

As result the port is set to the correct speed but is using always the half duplex 
mode as required by the IEEE 802.3u standard in such cases.  

For correct transmission, the non-negotiating port must be set to half-duplex 
mode (speed can be either 10 Mbps or 100 Mbps, it always will be recognized 
automatically by an Auto-Negotiation-Device). 

 

10.  LED Indicators 

The front panel of the Ethernet Switch contains several LED indicators. The function of 
each LED is described in the table below. 

LED 

Color 

Status 

Description 

PWR1 

Green 

On 

Power is being supplied to power input 
PWR1. 

Off 

Power is not being supplied to power input 
PWR1. 

PWR2 

Green 

On 

Power is being supplied to power input 
PWR2. 

Off 

Power is not being supplied to power input 
PWR2. 

LNK/ACT 
(RJ45 LAN Ports) 

Green 

On 

Port link is active. 

Off 

Port link is inactive. 

Blinking 

Transmitting data. 

Full/Half duplex 
(RJ45 LAN Ports) 

Amber 

On 

Port is set to Full Duplex mode. 

Off 

Port is set to Half Duplex mode. 

Blinking 

Half Duplex Mode: Packet collisions 
detected. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11.  Specifications 

Technology 

Standards  

IEEE 802.3 for 10Base-T 
IEEE 802.3u for 100Base-TX 
IEEE 802.3x flow control 

Processing Type 

Store and Forward 

MAC Table size 

8K 

Packet buffer size 

1 Mbit 

Backplane bandwidth 

4.8 Gbps 

Interfaces 

RJ45 Ports 

10/100BaseT(X) auto negotiation speed, Full/Half duplex 
mode and auto MDI/MDI-X connection 

LED Indicators 

PWR1, PWR2 (Power), LAN Port Link/Activity, Duplex Mode 
Setting (Half/Full Duplex) and Collision Detection 

Relay Contact 

Max. 1A @ 24 VDC  

Power 

Input Voltage 

24 V DC (12 - 48 V DC), 2 redundant inputs   

Input Current@24 VDC  0.39 A 
Connection 

One removable 6-pin terminal block, Wiring cable 12-24AWG 

Overload Current 
Protection 

Present 

Reverse Polarity 
Protection 

Present 

Physical Characteristics 

Housing 

IP30 protection, metal  

Dimension (W x H x D) 

96.4 x 154 x 108.5 mm (3.8 x 6.06 x 4.27 inch) 

Weight  

1052 g 

Installation 

DIN-rail 

Environmental conditions 

Operating Temperature  -40 to 75°C (-40 to 167°F) 
Storage Temperature 

-40 to 85°C (-40 to 185°F) 

Ambient Relative 
Humidity 

5 to 95% (non-condensing) 

Altitude 

up to 2000 m 

Regulatory Approvals 

Safety 

UL 61010-1; UL 61010-2-201 

EMS 

EN 55032, EN 55024, FCC Part 15 Subpart B Class A 
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV,  
IEC 61000-4-3 RS: 80 MHz to 1 Ghz: 3 V/m,  
IEC 61000-4-4 EFT: Power: 0.5 kV; Signal: 0.5 kV,  
IEC 61000-4-5 Surge: Power: 0.5 kV; Signal: 1 kV,  
IEC 61000-4-6 CS: 3 Vrms 

Shock 

IEC 60068-2-27 

Free Fall 

IEC 60068-2-31 

Vibration 

IEC 60068-2-6 

MTBF 

Time 

959.803 hrs 

Database 

Telcordia SR332 

Warranty 

Time Period 

5 years 

 

 

 

 

 

 

Contact Information 

 

Weidmüller Interface GmbH & Co. KG 

Klingenbergstraße 26, 32758 Detmold / Germany 

Phone +49 (0) 5231 14-0, Fax +49 (0) 5231 14-292083 

E-Mail 

[email protected]