Weidmüller IE-SW-EL08-8GT Скачать руководство пользователя страница 2

 

 

 

6                        Edition 6 / 2020-07 

8.  Wiring Redundant Power Inputs and Power Fault 

Relay 

The switch supports redundant power supply inputs and provides a power fault relay 
which can be used for alarming in case of interruption of Power 1 or Power 2 on the 6-
pin terminal block. Refer to illustration below for correct wiring. 
 

 

 Warning / Avertissement 

 Take into consideration the following guidelines before wiring the device 

o

 Tenez compte des directrices suivantes avant de câbler l’appareil. 

  Terminal block is mating with Plug and suitable for 12-24AWG. Torque 

value 4.5 lb-in. 

o

 Le bornier est compatible avec les connecteurs et convient pour 12-

24AWG. Valeur de couple 4,5 lb-in. 

  The temperature rating of the input connection cable should higher than 

105°C. 

o

 La température de service nominale du câble d’entrée doit être 

supérieure à 105 °C. 

  Supplied by SELV source evaluated by UL 61010-1 or 61010-2-201 

power supply only. 

o

 Fourni par la source SELV évaluée uniquement par l'alimentation UL 

61010-1 or 61010-2-201. 

 

 

Note about behavior of power failure relay: 

 

Relay contact is closed if the device is powered-off. 

 

Relay contact always is open if the device is powered either by PWR1 or PWR2 and if 
DIP switches 1 and 2 for power control are set to off. 

 

Relay contact closes if DIP switch 1 is set to ON and PWR1 fails. 

 

Relay contact closes if DIP switch 2 is set to ON and PWR2 fails. 

9.  Communication Connections 

Switch 

IE-SW-EL08-8GT

 is equipped with: 

8x 

10/100/1000Base-T(X) Ethernet ports (Auto MDI-X) 

Switch 

IE-SW-EL05-4GT-1GESFP

 is equipped with: 

4x 

10/100/1000Base-T(X) Ethernet ports (Auto MDI-X) 

1x 

1000Base-X slot to be used with SFP Transceivers (mini-GBIC) [accessories] 

Please only use cables suitable for the respective type of communication and ensure 
that signals are protected from possible interference. 

9.1 

10/100/1000Base T(X) RJ45 Ports 

The 10/100BaseT(X) ports located on Ethernet Switch’s front panel are used to 
connect to Ethernet-enabled devices. Below we show pinouts for both MDI (NIC-type) 
ports and MDI-X (HUB/Switch-type) ports. Auto MDI-X ensures that both wiring-
schemes are supported (Automatic crossover function). 

Pinouts 10/100/1000Base T(X) RJ45 

8-Pin RJ45 

Port 

10/100 Base-T(X) MDI/MDI-X 

1000Base-T MDI/MDI-X 

Pin No. 

MDI port 

MDI-X port 

Pin No. 

MDI port 

MDI-X port 

  

TD+(transmit) 

RD+(receive) 

BI_DA+ 

BI_DB+ 

TD-(transmit) 

RD-(receive) 

BI_DA- 

BI_DB- 

RD+(receive) 

TD+(transmit) 

BI_DB+ 

BI_DA+ 

Not used 

Not used 

BI_DC+ 

BI_DD+ 

Not used 

Not used 

BI_DC- 

BI_DD- 

RD-(receive) 

TD-(transmit) 

BI_DB- 

BI_DA- 

Not used 

Not used 

BI_DD+ 

BI_DC+ 

Not used 

Not used 

BI_DD- 

BI_DC- 

9.2 

1000BaseSFP Port (only IE-SW-EL05-4GT-1GESFP) 

The switch is equipped with an 1000BaseSFP slot that can be used with an optional 
SFP transceivers (mini GBIC). Please only use SFP modules and cables that are 
compatible with each other to establish an optical connection. Weidmüller provides 
transceiver models for various distance requirements. 

LC-Port with separate Transmit and Receive Port: 

Remember to connect the Tx (transmit) port of device I to the Rx (receive) port of device 
II, and the Rx (receive) port of device I to the Tx (transmit) port of device I 
 

LC-Port Pinouts

 

LC-Port to LC-Port Cable Wiring

 

 

 

10.  LED Indicators 

The front panel of the Ethernet Switch contains several LED indicators. The function of 
each LED is described in the table below. 

LED 

Color 

Status 

Description 

PWR1 

Green 

On 

Power is being supplied to power input PWR1. 

Off 

Power is not being supplied to power input PWR1. 

PWR2 

Green 

On 

Power is being supplied to power input PWR2. 

Off 

Power is not being supplied to power input PWR2. 

FAULT 

Amber 

On 

Indicates PWR1 or PWR2 fault (if 
corresponding DIP switches are set to ON). 

Off 

If DIP switches are set to OFF or no power failure. 

LNK/ACT (IE-
SW-EL08-8GT) 

Green 

Amber 

Green 

Port’s link is active at 1 Gbps. 

Amber 

Port’s link is active at 10/100 Mbps. 

Off 

Port’s link is inactive. 

LNK/ACT (IE-
SW-EL05-4GT-
1GESFP) 

Green 

On 

Port’s link is active. 

Off 

Port’s link is inactive. 

Full/Half Duplex 
(IE-SW-EL08-
8GT) 

Amber 

On 

Port is set to Full Duplex Mode. 

Off 

Port is set to Half Duplex Mode. 

Blinking 

Packet collisions detected. 

10/100/1000M 
(IE-SW-EL05-
4GT-1GESFP) 

Amber 

On 

Port speed is 100 Mbps. 

Off 

Port speed is 10 Mbps or 1 Gbps (Full Duplex). 

LNK/ACT 
1000Base-X 
(IE-SW-EL05-
4GT-1GESFP) 

Green 

On 

Fiber-Link is active. 

Off 

Fiber-Link is inactive. 

11.  Specifications 

Technology 

Standards  

IEEE 802.3 for 10Base-T, 
IEEE 802.3u for 100Base-TX 
IEEE 802.3z for 1000Base-X  
IEEE 802.3ab for 1000Base-T 
IEEE 802.3x flow control 

Processing Type 

Store and Forward 

MAC Table size 

IE-SW-EL05-4GT-1GESFP: 1K; IE-SW-EL08-8GT: 4K 

Packet buffer size 

IE-SW-EL05-4GT-1GESFP: 1 Mbit 
IE-SW-EL08-8GT: 1.5 Mbit 

Backplane bandwidth 

IE-SW-EL05-4GT-1GESFP: 10 Gbps 
IE-SW-EL08-8GT: 16 Gbps 

Jumbo frame support 

IE-SW-EL05-4GT-1GESFP: up to 10 KB 
IE-SW-EL08-8GT: 9216 Bytes 

Interfaces 

RJ45 Ports 

10/100/1000BaseT(X) auto negotiation speed, F/H duplex 
mode and auto MDI/MDI-X connection 

SFP slot  

1000Base-X 

LED Indicators 

PWR1, PWR2 (Power), Power Fault, Port Link/Activity, 
Port Full/Half Duplex Mode 

Relay Contact 

Max. 1A @ 24 VDC  

DIP Switches 

Enabling/Disabling relay alarm for PWR1/PWR2 failure  

Power 

Input Voltage 

24 V DC (12 - 48 V DC), 2 redundant inputs  

Input Current @24 VDC  IE-SW-EL05-4GT-1GESFP: 0.18 A; IE-SW-EL08-8GT: 0.2 A 
Connection 

One removable 6-pin terminal block, Wiring cable 12-24AWG 

Overload Current 
Protection 

Present 

Reverse Polarity 
Protection 

Present 

Physical Characteristics 

Housing 

IP30 protection, metal  

Dimension (W x H x D) 

26.1 x 144.3 x 94.9 mm (1.03 x 5.68 x 3.74 in) 

Weight  

IE-SW-EL05-4GT-1GESFP: 403 g; IE-SW-EL08-8GT: 390 g 

Installation 

DIN-rail 

Environmental conditions 

Operating Temperature  -40 to 75°C (-40 to 167°F) 
Storage Temperature 

-40 to 85°C (-40 to 185°F) 

Ambient Relative 
Humidity 

5 to 95% (non-condensing) 

Altitude 

up to 2000 m 

Regulatory Approvals 

Safety 

UL 61010-1, UL 61010-2-201 

EMC 

EN 55032, EN 55024, FCC Part 15 Subpart B Class A,  
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV,  
IEC 61000-4-3 RS: 80 MHz to 1 Ghz: 3 V/m,  
IEC 61000-4-4 EFT: Power: 0.5 kV; Signal: 0.5 kV,  
IEC 61000-4-5 Surge: Power: 0.5 kV; Signal: 1 kV,  
IEC 61000-4-6 CS: 3 Vrms 

Shock 

IEC 60068-2-27 

Free Fall 

IEC 60068-2-31 

Vibration 

IEC 60068-2-6 

MTBF 

Time 

IE-SW-EL08-8GT: 926.332 hrs 
IE-SW-EL05-4GT-1GESFP: 1.861.840 hrs 

Database 

Telcordia SR332 

Warranty 

Time Period 

5 years 

 

Contact Information 

 

Weidmüller Interface GmbH & Co. KG 

Klingenbergstraße 26, 32758 Detmold / Germany 

Phone +49 (0) 5231 14-0, Fax +49 (0) 5231 14-292083 

E-Mail 

[email protected]

,  Internet 

www.weidmueller.com 

Отзывы: