Weidmüller 2682350000 Скачать руководство пользователя страница 2

 

 

 

6                   V1.4 / 2022-03-29 

 

 Warning / Avertissement 

 Take into consideration the following guidelines before wiring the device 

o

 Tenez compte des directrices suivantes avant de câbler l’appareil. 

  Terminal block is mating with Plug and suitable for 12-24AWG. Torque 

value 4.5 lb-in. 

o

 Le bornier est compatible avec les connecteurs et convient pour 12-

24AWG. Valeur de couple 4,5 lb-in. 

  The temperature rating of the input connection cable should higher than 

105°C. 

o

 La température de service nominale du câble d’entrée doit être 

supérieure à 105 °C. 

  Supplied by SELV source evaluated by UL 61010-1 or 61010-2-201 

power supply only. 

o

 Fourni par la source SELV évaluée uniquement par l'alimentation UL 

61010-1 or 61010-2-201. 

 

 

Behavior of fault alarm relay (can be triggered by configurable events power 
failure or port link down):  

 

Relay contact is closed if the device is powered-off. 

 

Relay contact is open if the device is powered-on and no alarm conditions exist (neither 
Power Failure Alarms nor Port Link Loss Alarms are activated (Web menu Warnings 

 

Fault Relay Alarm). 

 

Relay contact closes if any of an activated alarm condition happens. 

9.  Communication Connections 

Switch 

IE-SW-AL08M-8GT

 is equipped with: 

8 x 10/100/1000BASE-T(X) Ethernet ports (Auto MDI-X) 

Please only use cables suitable for the respective type of communication and ensure 
that signals are protected from possible interference. 

9.1 

10/100/1000BASE-T(X) RJ45 Ports 

The 10/100/1000BASE-T(X) ports located on Ethernet Switch’s front panel are used to 
connect to Ethernet-enabled devices. Below we show pinouts for both MDI (NIC-type) 
ports and MDI-X (HUB/Switch-type) ports. Auto MDI-X ensures that both wiring-
schemes are supported (Automatic crossover function). 

10/100/1000BASE-T(X) RJ45 Pinouts

 

8-Pin RJ45 

Port 

10/100BASE-T(X) MDI/MDI-X 

1000BASE-T MDI/MDI-X 

Pin No. 

MDI port 

MDI-X port 

Pin No. 

MDI port 

MDI-X port 

  

TD+(transmit) 

RD+(receive) 

BI_DA+ 

BI_DB+ 

TD-(transmit) 

RD-(receive) 

BI_DA- 

BI_DB- 

RD+(receive) 

TD+(transmit) 

BI_DB+ 

BI_DA+ 

Not used 

Not used 

BI_DC+ 

BI_DD+ 

Not used 

Not used 

BI_DC- 

BI_DD- 

RD-(receive) 

TD-(transmit) 

BI_DB- 

BI_DA- 

Not used 

Not used 

BI_DD+ 

BI_DC+ 

Not used 

Not used 

BI_DD- 

BI_DC- 

9.2 

RS232 Console Port  

The RS232 Interface with RJ45 connector can be used to access the switch console for 
configuration. Additional it can be applied with external Backup/Restore module IE-
EBR-MODULE-RS232-ALM (Article no. 2682610000). 
 
Pinouts Serial  
Console Port: 
 
 
 
 
 
 

10.  User Management  

10.1  Device Access (Login to Web Interface) 

The Web interface of the Switch can be accessed via following factory default settings: 

IP address / Netmask: 

192.168.1.110 / 255.255.255.0

 

User name: 

admin

 

Password: 

Detmold

 

Connect the PC to any Ethernet port of the managed Switch and set the PC’s IP 
address to a free one of range 192.168.1.0 / 255.255.255.0 

Start a web browser and enter the IP address of the connected Switch into the 
browser’s address line (http://192.168.1.110). After the appearance of prompt (login) 
enter the login credentials. After confirmation of your input with "OK" the home page of 
the switch will be displayed. 

10.2  Reset Button (Behavior of Factory Default Settings) 

  Pressing < 5 seconds: Reboot the switch (Warm Start) and sets IP to Factory 

Default IP. 

  Pressing >= 5 seconds: Resets the switch configuration to Factory Default Settings. 

Note: Behavior of reset button can be configured in the Web Interface (Menu Factory Default). 

11.  LED Indicators 

The front panel of the Ethernet Switch contains several LED indicators. The function of 
each LED is described in the table below. 

LED 

Color 

Status 

Description 

PWR1 

Green 

On 

Power is supplied to power input PWR1. 

PWR2 

Green 

On 

Power is supplied to power input PWR2. 

R-MSTR 
(Ring Master) 

Green 

On 

Is Ring Master of an enabled O-Ring. 

Ring 

Green 

On 

O-Ring redundancy is enabled. 

Blinking 

Ring structure is broken (No redundancy). 

LNK/ACT 

Green 

On 

Port’s link is active. 

Off 

Port’s link is inactive. 

Blinking 

Data is transmitted. 

10/100/1000M 

Green / 

Amber 

Green 

Port speed is set to 1000 Mbps. 

Amber 

Port speed is set to 100 Mbps. 

Off 

Port speed is set to 10 Mbps. 

FAULT 

Amber 

On 

Fault Relay indication for Power failure and 
Port link loss. 

12.  Disposal Information 

 

Observe the notes for proper disposal of the 
product. You can find the notes here: 

www.weidmueller.com/disposal

 
  

 

13.  Specifications 

Technology 

Ethernet Standards  

IEEE 802.3 for 10BASE-T 
IEEE 802.3u for 100BASE-TX 
IEEE 802.3z for 1000BASE-X 
IEEE 802.3x for flow control 
IEEE 802.3az Energy-Efficient Ethernet 
IEEE 802.3ad for port trunk with LACP 
IEEE 802.1D for STP (Spanning Tree protocol) 
IEEE 802.1w for RSTP (Rapid Spanning Tree protocol) 
IEEE 802.1s for MSTP (Multiple Spanning Tree Protocol) 
IEEE 802.1p for Class of Service 
IEEE 802.1Q for VLAN Tagging 
IEEE 802.1X for Authentication 
IEEE 802.1AB for LLDP (Link Layer Discovery Protocol) 

Processing Type 

Store and Forward 

MAC Table size 

8K 

Packet buffer size 

4 Mbit 

Backplane bandwidth 

16 Gbps 

Jumbo frame support 

Up to 9.6 kBytes 

Interfaces 

RJ45 Ports 

10/100/1000BASE-T(X) auto negotiation speed, F/H duplex 
mode and auto MDI/MDI-X connection 

RS232 Console Port 

RS232 Interface with RJ45 connector for Console access and 
useable with external Backup/Restore module 

LED Indicators 

PWR1, PWR2 (Power), Fault (Relay), Ring Master, Ring 
Status, Port Link/Activity, Port Full/Half Duplex Mode 

Relay Contact 

Max. 1A @ 24 V DC for Power Failure and Port Link Loss 

Power 

Input Voltage 

24 V DC (12 - 48 V DC), 2 redundant inputs  

Power Consumption (typ.) 

13.2 Watts 

Connection 

One removable 6-pin terminal block, Wiring cable 12-24AWG 

Overload Current Protect. 

Present 

Reverse Polarity Protect. 

Present 

Physical Characteristics 

Housing 

IP30 protection, metal  

Dimension (W x H x D) 

54.3 x 145.1 x 108.3 mm (2.13 x 5.71 x 4.26 inch.) 

Weight  

779 g 

Installation 

DIN-rail 

Environmental conditions 

Operating Temperature 

-40 to 75°C (-40 to 167°F) 

Storage Temperature 

-40 to 85°C (-40 to 185°F) 

Ambient Relative Humidity 

5 to 95% (non-condensing) 

Operating Altitude 

Up to 2000 m 

Regulatory Approvals 

Safety 

UL 61010-1; UL 61010-2-201 

EMC 

EN 55032, EN 55024, FCC Part 15 Subpart B Class A,  
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV,  
IEC 61000-4-3 RS: 80 MHz to 1 Ghz: 3 V/m,  
IEC 61000-4-4 EFT: Power: 0.5 kV; Signal: 0.5 kV,  
IEC 61000-4-5 Surge: Power: 0.5 kV; Signal: 1 kV,  
IEC 61000-4-6 CS: 3 Vrms 

Shock 

IEC 60068-2-27 

Free Fall 

IEC 60068-2-31 

Vibration 

IEC 60068-2-6 

MTBF 

Time 

508.672 hrs 

Database 

Telcordia SR332 

Warranty 

Time Period 

5 years 

 

Contact Information 

 

Weidmüller Interface GmbH & Co. KG 

Klingenbergstraße 26, 32758 Detmold / Germany 

Phone +49 (0) 5231 14-0, Fax +49 (0) 5231 14-292083 

E-Mail 

[email protected]

,  Internet 

www.weidmueller.com 

 

Отзывы: