Power
Input Voltage
12/24/48 V DC (9.6 to 60 V DC), 2 redundant inputs
Input Current
IE-SW-VL05M series:
0.594 A/0.286 A/0.154 A @ 12/24/48 V
IE-SW-VL08MT series:
0.61 A/0.3 A/0.16 A @ 12/24/48 V
IE-SW-VL08MT-5TX-3SC/2SCS-1SC:
0.73 A/0.35 A/0.18 A @ 12/24/48 V
Connection
One removable 6-pin terminal block
Overload Current
Protection
Present
Reverse Polarity
Protection
Present
Mechanical
Housing
Metal, IP30 protected
Dimensions
53.6
135
105 mm (W
H
D)
Weight
0.65 kg (IE-SW-VL05M series)
0.89 kg (IE-SW-VL08MT series)
Installation
DIN-Rail, Wall Mounting (optional kit)
Environment
Operating
Temperature
Standard models: -10 to 60°C (14 to 140°F)
Wide temp. models: -40 to 75°C (-40 to 167°F)
Storage
Temperature
-40 to 85°C (-40 to 185°F)
Ambient Relative
Humidity
5% to 95% (non-condensing)
Regulatory Approvals
Safety
UL60950-1, UL 508, EN60950-1
Hazardous
Location
UL/cUL Class I, Division 2, Groups A, B, C, and D
ATEX Zone 2: only IE-SW-VL08MT series (copper
and 2 fiber models):
EN 60079-0:2012+A11:2013
EN 60079-15:2010
EN 60079-28:2015
(for IE-SW-VL08MT-2SC/2ST/2SCS only)
EMC
EN 55032/24; CISPR 32, FCC Part 15B Class A
IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m
IEC 61000-4-4 EFT: Power: 2 kV; Signal: 1 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8
Shock
IEC60068-2-27
Freefall
IEC60068-2-31
Vibration
IEC60068-2-6
MTBF
(meantime between failures)
Time
1,547,941 hrs (IE-SW-VL05M(T)-5TX models)
1,429,327 hrs (IE-SW-VL05M(T)-3TX models)
1,339,439 hrs (IE-SW-VL08MT-8TX/6TX models)
1,253,072 hrs (IE-SW-VL08MT-5TX models)