Opening the Enclosure / Klippon TB MH Version
Place enclosure in a vertical upright position. Loosen the lid cover fixings screws with a
suitable tool (refer to diagram 1 below). After loosening the covers screws, the lid can
be opened up to approximately 130°.
Removing the lid
The lid should be removed by loosening the cover fixing screws and any attached lid
bonding cable with a suitable tool. After loosening the fixing screws the cover lid must
be opened to a 90° position (refer to diagram 2 below). With the lid in this position, lift
the lid slightly and slide to the outside to release (refer to diagram 3 below). In this way
you are able to fix the lid to either the left or the right hand side of the enclosure (multi
hinge version only). If the lid position is to be fixed to another side, it is also necessary
to reposition the padlock lug to the opposite side.
NOTE
Do not remove the captive element of the screws!