background image

 

LED Indicators 

Several LED indicators are located on the IE-SW-IP67(T)-5M12 front 
panel. The function of each LED is described in the table below. 

LED 

Color 

State 

Description 

PWR 

AMBER 

On 

Power is being supplied to the power 
input. 

Off 

Power is 

not

 being supplied to the 

power input. 

LNK/ACT 

(10M) 

AMBER 

On 

TP port’s 10 Mbps link is active. 

Blinking  Data is being transmitted at 10 Mbps 

Off 

TP port’s 10 Mbps link is inactive. 

LNK/ACT 

(100M)

 

GREEN 

On 

TP port’s 100 Mbps link is active 

Blinking 

Data is being transmitted at 100 
Mbps. 

Off 

TP port’s 100 Mbps link is inactive. 

 

Auto MDI/MDI-X Connection 

The Auto MDI/MDI-X function allows users to connect IE-SW-IP67(T)-
5M12’s 10/100BaseTX ports to any kind of Ethernet device, without 
needing to pay attention to the type of Ethernet cable being used for the 
connection. This means that you can use either a straight-through cable 
or cross-over cable to connect the IE-SW-IP67(T)-5M12 to Ethernet 
devices. 
 

Dual Speed Functionality & Switching 

The IE-SW-IP67(T)-5M12 10/100 Mbps switched M12 ports auto 
negotiate with the connected device to use the fastest data 
transmission rate supported by both devices. All of Weidmül

ler’s 

unmanaged switches are plug-and-play devices, so that software 
configuration is not required. The half/full duplex mode for the switched 
M12 ports is user dependent and changes (by auto-negotiation) to full 
or half duplex, depending on which transmission speed is supported by 
the attached device. 

Switching and Address Learning 

The IE-SW-IP67(T)-5M12 has an address table that can hold up to 
1000 node addresses, which makes it suitable for use with large 
networks. The address tables are self-learning, so that as nodes are 
added or removed, or moved from one segment to another, the IE-SW-
IP67(T)-5M12 automatically keeps up with new node locations. An 
address-aging algorithm causes the least-used addresses to be deleted 
in favor of newer, more frequently used addresses. To reset the 
address buffer, power down the unit and then power it back up. 

 
 
 
 

Содержание IE-SW-IP67-5M12

Страница 1: ...roduct information can be downloaded using following link http www weidmueller com Select Product Catalogue Select Industrial Ethernet active Select IP67 unmanaged Switches Select Product model Click...

Страница 2: ...Class 1 Division 2 and comply with CE FCC and UL standards Package Checklist Your Ethernet Switch is shipped with the following items If any of these items is missing or damaged please contact your We...

Страница 3: ...ed M12 socket with D coding 3 Port Label 4 Power input 5 pin male shielded M12 socket with A coding 5 Power input PWR LED 6 Device Type 7 Holes for attaching the IE SW IP67 T 5M12 to a wall with screw...

Страница 4: ...3 screw holes on the wall based on the positions of the 3 screw holes on the switch shown in the mounting dimensions diagram STEP 2 Insert one screw in the top middle screw hole on the switch and scre...

Страница 5: ...nd common wire Observe all electrical codes dictating the maximum current allowable for each wire size If the current goes above the maximum ratings the wiring could overheat causing serious damage to...

Страница 6: ...T X Ethernet ports 4 pin shielded M12 socket with D coding The 10 100BaseTX ports located on the front panel are used to connect to Ethernet enabled devices Most users configure these ports for Auto M...

Страница 7: ...D Power input Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Input V Not assigned Input V Not assigned Function ground Pinouts for RJ45 8 pin RJ45 8 Pin MDI Port Pinouts MDI X Port Pinouts Pin Signal 1 Tx 2 Tx 3 Rx 6...

Страница 8: ...8 M12 4 pin M to M12 4 pin M Straight Trough Cable Wiring M12 4 pin M to RJ45 8 pin Cross Over Cable Wiring M12 4 pin M to RJ45 8 pin Straight Trough Cable Wiring...

Страница 9: ...the IE SW IP67 T 5M12 to Ethernet devices Dual Speed Functionality Switching The IE SW IP67 T 5M12 10 100 Mbps switched M12 ports auto negotiate with the connected device to use the fastest data tran...

Страница 10: ...for speeds in the 10BaseT and 100BaseTX modes with operation according to the IEEE 802 3u standard This means that some nodes could be operating at 10 Mbps while at the same time other nodes are opera...

Страница 11: ...verload Current Protection 1 1 A Reverse Polarity Protection Present Physical Characteristics Housing Plastic IP67 protection Dimensions 60 x 125 x 29 6 mm W x H x D Weight 250 g Installation Panel Wa...

Страница 12: ...otherwise in writing in this catalogue product description Weidm ller gives no warranty or guarantee as to the interoperability in specific systems or as to the fitness for any particular purpose To t...

Отзывы: