background image

D-2009/09/00712-8-3 | Date: 08/2019

OPERATING INSTRUCTIONS

Type

 TSA1 H

2

 70 MPa

Breakaway coupling for hydrogen refuelling  

at car refuelling stations

WEH

®

 - We Engineer Hightech

Содержание TSA1 H2 70 MPa

Страница 1: ...D 2009 09 00712 8 3 Date 08 2019 OPERATING INSTRUCTIONS Type TSA1 H2 70 MPa Breakaway coupling for hydrogen refuelling at car refuelling stations WEH We Engineer Hightech...

Страница 2: ...2009 09 00712 8 3 CONTENTS PLEASE NOTE 3 1 GENERAL SAFETY INSTRUCTIONS 3 2 APPLICATION 4 3 INSTALLATION 5 4 EXAMINATION AFTER SEPARATION 8 5 ACCESSORIES SPARE PARTS 8 6 STORAGE 8 7 MAINTENANCE 9 8 EX...

Страница 3: ...GENERAL SAFETY INSTRUCTIONS For your own safety please observe the following instructions 1 1 Please conform to any relevant legal directives such as for instance any national legisla tion on safety...

Страница 4: ...orresponds to the product marking 2 1 3 Suitability for application When selecting a component the total system design must be considered to ensure safe trouble free performance The correct se lection...

Страница 5: ...outlet B2 B1 TSA1 H2 70 MPa 1 Breakaway coupling body 2 Eccentric actuator 3 Filter internal 4 Receptacle insert 5 Mounting 6 Guide tube 7 Fixing elements 8 Retaining brackets 9 Data cable TSA1 H2 70...

Страница 6: ...depressurized via the dispenser for every actuation 3 1 4 The torques will change when using other fittings see Chapter 5 Accessories Spare Parts depending on the thread size Please contact us 3 1 5 T...

Страница 7: ...table 3 2 5 Insert the receptacle insert pos 4 with the filling hose connected through the guide tube pos 6 of the mounting pos 5 3 2 6 Connect the media inlet B1 pressure tight to the media port of...

Страница 8: ...event of accidental deployment e g driving a vehicle from the dispenser with the nozzle remaining in the vehicle fuel port the breakaway coupling will separate the connection between dispenser and fil...

Страница 9: ...ingress damage The product has to be sent to the manufacturer for refurbishment after 3 years at the latest 7 2 The filter should be serviced on a regular basis see separate maintenance instructions...

Страница 10: ...about the result of the measurement 8 1 4 Please note that the sensor might display a higher value not caused by hydro gen if the hydrogen fuelling station is integrated into a liquid fuels station I...

Страница 11: ...igure 4 so that the pressure may escape unhindered Keep the vent hole away from your body and your face Keep your hands or fingers away from the hole DANGER OF INJURY 9 1 5 Loosen the screw connection...

Страница 12: ...clamping jaws open 9 3 2 Insert the receptacle insert pos 4 into the breakaway coupling body pos 1 9 3 3 Turn the eccentric actuator pos 2 again by 180 the clamping jaws grip the receptacle insert 9 3...

Страница 13: ...12 8 3 10 DIMENSIONS WEH TSA1 H2 70 MPa Breakaway Coupling approx dimensions mm Description Pressure PN B1 internal thread B2 external thread TSA1 H2 70 MPa with filter 20 micron 700 bar UNF 9 16 18 U...

Страница 14: ...B1 B2 Description Pressure PN B1 internal thread B2 external thread TSA1 H2 70 MPa with filter 20 micron 700 bar UNF 9 16 18 UNF 9 16 18 60 cone MP fitting 60 inner cone All rights reserved WEH GmbH 2...

Отзывы: