background image

UTY4000-007

4

REPORT COMMOND is “r p.”  The report will show if any sync data cards are
available.  The line will read as follows:

 

Sync Data Card #(1 or 2): INSTALLED

 

 

The SYNC DATA report command is “r sd.”  The report will report the sync data
card status in the following form:

 

FUNCTION  CURRENT SETTING

 

RS422  OUTPUT  ENABLED/DISABLED

 

LVDS OUTPUT

 ENABLED/DISABLED

 

SYNC  DATA  RATE  data rate

 

PID

PID

 

STATUS

 

3.2   From Front-panel

Ÿ

 

Sync Data Card setup with local control disabled:

The sync data card setup cannot be accessed via the front panel with local control
disabled.  The Network must authorize local control.

Ÿ

 

Sync Data Card setup with local control enabled:

The sync data card can be set via the front panel, if local control is enabled, by using the
menu path HARDWARE SETUP / CONTROL SYNC DATA.  Select the parameter you
need to adjust by using the right/left arrows and the <SELECT> key.  Use the up/down
arrows to select the desired setting.  Press the <ENTER> key to initialize the settings.

Ÿ

 

Sync Data Card status

:  To confirm that the Sync Data card option is available via the

front panel follow the menu path STATUS REPORTS / PARAMETER STATUS.  Use the
right/left arrow keys to scroll to SYNC DATA.

To view how the sync data card is configured via the front panel follow the menu path
STATUS REPORTS / SYNC DATA STATUS.  Use the right/left arrow keys to scroll
through the audio ports configuration.

Содержание Unity Satellite Receiver Model Unity Synchronous Data Option

Страница 1: ... Communications Inc When ordering parts from Wegener Communications Inc be sure to include the equipment model number equipment serial number and a description of the part In all correspondence with Wegener Communications Inc regarding this publication please refer to UTY4000 007B First Edition February 1999 Revised June 2000 WEGENER COMMUNICATIONSR TECHNOLOGY PARK JOHNS CREEK 11350 TECHNOLOGY CIR...

Страница 2: ... installed into either inboard Module 1 or outboard Module 2 position 3 Remove block out plate for selected position Save hardware 4 Install PWB into selected position Take precautions against Electro static discharge to avoid damage to module 5 Connect supplied 24 pin cable from J13 on the motherboard to J1 on the Sync Data Option card 6 Set jumpers on option card J9 is the only jumper configurab...

Страница 3: ...abled If so only the status monitoring will be possible 3 1 From Terminal Ÿ Sync data card setup with local control disabled The sync data card setup cannot be accessed via the terminal with local control disabled Local control will have to be authorized by the network Ÿ Sync data card setup with local control enabled CSD cmd param port Cmd R Set RS422 output state L Set LVDS output state D Set da...

Страница 4: ...l control Ÿ Sync Data Card setup with local control enabled The sync data card can be set via the front panel if local control is enabled by using the menu path HARDWARE SETUP CONTROL SYNC DATA Select the parameter you need to adjust by using the right left arrows and the SELECT key Use the up down arrows to select the desired setting Press the ENTER key to initialize the settings Ÿ Sync Data Card...

Страница 5: ...07 Figure 1 UTY4000 Sync Data Kit Installation UNITY4000 MOTHER BOARD P S STANDOFFS Front Rear Module 2 Module 1 J11 Pin 1 1 Mounting Bracket J13 Pin 1 J1 Pin 1 J12 Pin 1 Screws from blockout plate Screws from kit ...