Wegener i6420 Скачать руководство пользователя страница 2

Version 2.0 01/31/14 

 
Page 

2

 of 

7

 

 

INSTALLATION INSTRUCTIONS 

 

 

1)  This receiver should be installed in a location that maintains a consistent 

temperate of 65-75 degrees with ample ventilation to the front, sides and rear 
of the receiver.  

2)  Connect your RG-6 cable from your satellite dish to the RF input on the back 

of the receiver.  If more than one receiver is to be connected, a professional 
grade splitter with a DC power pass port is recommended. 

a.  Note: In a multi-receiver installation, it is recommended to use a 

professional power inserter and not to power your LNB from the 
Wegener receiver.   

3)  Connect your stations broadband network (internet) to the receiver at the LAN 

port if your network is behind a firewall (common) or the WAN port if outside a 
firewall (uncommon).   

a.  Note: A reliable network connection is 

required

 to maintain a network 

“return path” communication with our network in order to ensure 
proper functionality of the receiver.  This is an outbound 
communication only and must be maintained at all times.  Because of 
this requirement, we are unable to authorize receivers that are not 
connected with this “return path”.  If your station does not have public 
internet access, please contact Network Operations for assistance. 

4)  Connect the in-house AM or FM signal antenna or an independent AM/FM 

antenna to the port(s) corresponding with the programs identified on page 1.  

a.  Note: This is a 

required

 connection and must be maintained at all 

times.    

5)  Connect your DB9 audio and DB37 relay connectors to the ports 

corresponding with the programs identified on page 1. 

6)  Plug the receiver into a reliable, stable and properly grounded power source. 

a.  Note: Wegener and WestwoodOne strongly recommend that you use 

an Uninterruptible Power Supply (UPS) with power line filtering to 
prevent damage to the unit during electrical storms or power surges.  
Please be aware that electrical damage caused by lightning or power 
surges is not covered under the warranty.  RF surge filtering is also 
strongly recommended for this reason. 

7)  Verify your dish alignment and signal strength by looking at the EbNo and RF 

levels.  EbNo must be at least 9.0 and RF between 20-60 in order to 
authorize the receiver.   

a.  Note:  A distribution amplifier is not recommended for main cable runs 

less than 250 ft.  If amplification is necessary to attain minimum specs, 
a line amp ahead of the splitter yields more favorable results. 

b.  Note: Line attenuators to drop RF to within maximum RF levels should 

be used sparingly to avoid unnecessary noise injection.     

8)  Once all connections are made, and levels meet minimum specifications, 

please contact WestwoodOne Network Operations for authorization.   