background image

800043-02 Rev. A

Page 3 of 6

July 21, 2004

Environmental Operating Conditions & Physical Specifications

Use

Indoor

Altitude

Up to 2000 meters

Temperature Range

0

 o

 C to +50

 o

 C

Relative Humidity (max.)

80% for temperatures up to 31

C decreasing linearly to 50% relative

humidity at 40

C.

Weight

10.6 pounds or 4.81 kilograms

Dimensions (H x W x D)

3.5”x 19”x 10.5” or 88.9 mm x 482.6 mm x 266.7 mm

Input Power Rating

90-132Vac & 175-264Vac, 43 Watt, 50/60 Hz

Front-panel User Interface

Note that from any screen, pressing the ESC key twice will return you to the Home Screen.

Main-level Screens

Second-level Screens

Home Screen

  (rotates through status of each input) The following are

examples of typical home screens:

Where 

XX

 is the broadcast channel number, 

YY.Y

 is the signal-to-noise

ratio, and 

ZZZZ

 is the number of errored seconds since the last reset of the

counter or the last lock of input.

Press the 

4

4

 key to go to Alarms/Warnings.

Press the 

ENT

 key to view the second-level Serial Number and Application

Software Version Number screen.

Serial Number and Application Software Version Number Screen

Where 

XXXXXX

 is the unit's six-digit serial number and 

YYY

 is the version number

of the unit's currently installed application software.

Press the 

ESC

 key to go to the Home Screen.

Alarms/Warnings

Press the 

ENT

 key to view any active alarms or warnings on the second-

level Alarms/Warnings Message screen.

Press the 

4

4

 key to go to Clear Errored Seconds (if counter is non-zero) or

Program Setup.

Press the 

ESC

 key to go to the Home Screen.

Alarms/Warnings Message Screen

Any active alarms or warnings are described here.

Press the 

4

4

 key to view the next alarm or warning (if more than one).

Press the 

ESC

 key to return to the Alarms/Warnings screen.

Clear Errored Seconds

Press the 

ENT

 to clear the errored seconds counter.

Press the 

4

4

 key to go to the Input Setup screen.

Press the 

3

3

 key to go to Alarms/Warnings.

Press the 

ESC

 key to go to the Home Screen.

R F 1   C h a n : X X         8 V S B
S N R Y Y . Y   E r r S e c : Z Z Z Z

V i e w   A l a r m s / W a r n i n g s

C l e a r   E r r o r e d   S e c s
P r e s s < E N T >

S / N : X X X X X X
V E R : Y Y Y

A S I   1   E n a b l e d
E r r   S e c s :   0 0 0 0

N o   A l a r m s   o r   W a r n i n g