General 

 

After a first successful starting test, couple the motor to 
the driven load, and then the starting procedure can be 
reinitiated, as follows:  

 

Start the motor coupled to the load until its temperature 
stabilizes and check for unusual noises, abnormal 
vibrations or excessive heating. If significant vibration 
variations occur regarding the initial operation condition 
until the condition after reaching thermal stability, then it 
is necessary to check the alignment and the leveling.  

 

Measure the current consumption and compare it to 
the value given on the nameplate. 

 

In continuous duty, without load variation, the measured 
current must not exceed the value indicated on the 
nameplate multiplied by the service factor;  

 

All the instruments and devices for measurement and 
control must be permanently monitored to detect 
occasional alterations, determine their causes and 
make the proper corrections. 

 

6.3.2

 

Temperatures 

 

 

The temperatures of the bearings, stator winding and 
cooling system must be monitored while the motor is 
operating. 

 

These temperatures must stabilize within 4 to 8 hours of 
operation. 

 

The stator winding temperature depends on the 
machine load; therefore, the driven load must also be 
monitored during the motor.  

 

6.3.3

 

Bearings 

 

The system start, as well as the first hours of operation, 
must be monitored carefully. 

 

During the first starting, it is important to pay attention 
to unusual vibrations or noises; If the bearing is not 
working silently and smoothly, shut the motor down, 
identify de cause and correct it; 

 

In case of overheating, the motor must be shut down 
immediately for the inspection of bearings and 
temperature sensors, and the correction of possible 
causes; 

 

After the bearing temperatures stabilize, check if there 
are no leaks through the plugs, gaskets or shaft end. 

 

6.3.4

 

Cooling system 

 

 

ATTENTION 

The motor cannot be operated without water 
in the cooling system.

 

 

 

Adjust the water flow and pressure, as indicated on the 
plate affixed to the motor; 

 

For operation control purposes, it is recommended that 
the cooling water temperatures at the inlet and outlet as 
well as the differential pressure at the water inlet and 
outlet be measured and recorded periodically;  

 

These values must be periodically compared to the 
original value, and an increase in the pressure 
differential or a water temperature rise indicates the 
need for cleaning the motor water circuit. 

 
 
 
 
 
 
 

6.3.5

 

Vibration 

 

The motors are balanced at the factory in compliance with 
the vibration limits established by IEC60034-14, NEMA 
MG1 – Part 7 and NBR 11390 standards (except when 
the purchase contract specifies different values).   
The vibration measurements are carried out on the NDE 
and DE bearings, in the vertical, horizontal and axial 
directions. When the customer sends the half coupling to 
WEG, the motor is balanced with the half coupling 
mounted on the shaft. Otherwise, according to the 
standards above, the motor is balanced with half-key (i.e., 
the key slot is filled with a bar of the same width, thickness 
and height of the key slot during the balancing operation).  
The maximum vibration levels attended by WEG for 
motors in operation are informed in Table 6.1. These 
values are generic and for guidance, and the specific 
application conditions must always be taken into account: 

 

Table 6.1: Vibration (RMS)  

  Rated speed 

(rpm) 

Vibration Levels (mm/s RMS) 

Frame  

< 355  355 to 560

> 630 

600 ≤ n ≤ 1800

Alarm 4.5  4.5 

5.5 

Tripping 7.0 

7.0 

8.0 

1800 < n ≤ 3600

Alarm 3.5  4.5 

5.5 

Tripping 5.5 

6.5 

7.5 

 
The main vibration causes are: 

 

Misalignment between the motor and the driven 
equipment; 

 

Improper fastening of the motor to the base, with 

“loose shims

” under one or more motor feet, and loose 

fastening bolts; 

 

Improper or insufficiently rigid base; 

 

External vibrations proceeding from other equipment. 

 

 

ATTENTION 

Operating the motor with vibration levels 
above the values contained in Table 6.1 may 
impair its useful life and/or performance.

 

 

6.3.6

 

Shutdown 

 

In order to shut down the motor, proceed as follows:  

 

Reduce the load of the driven equipment, if possible; 

 

Open the main circuit breaker. 

After the motor stops completely: 

 

Shut down the motor cooling water supply system; 

 

Switch on the space heaters. They must be kept ON 
until the next motor operation. 

 

 

DANGER 

Even after switching the motor off, while the 
rotor is rotating, there is danger to life by 
touching any of the motor active parts. 

 

 

 
 

ATTENTION 

The terminal boxes of motors equipped with 
capacitors must not be opened before the 
discharge time. 
Discharge time of the capacitors: five 
minutes after shutting down the motor.

 

 

Содержание WGM

Страница 1: ...Automation I Energy I Transmission Distribution I Coatings Three phase induction motors cooled by water jacket W line Squirrel cage rotor Horizontal and Vertical Installation Operation and Maintenanc...

Страница 2: ......

Страница 3: ...Installation Operation and Maintenance Manual Document Number 11239449 Model WGM Language English Revision 8 February 2017...

Страница 4: ......

Страница 5: ...motor Therefore we recommend that you read this manual carefully before proceeding with the installation operation or maintenance of the motor in order to ensure safe and reliable operation of your eq...

Страница 6: ......

Страница 7: ...ated rolling bearing 17 3 3 3 6 Terminal box 17 3 3 3 7 Inspections and records during storage 17 3 3 3 8 Predictive preventive maintenance 17 3 3 3 9 Maintenance plan during storage 18 3 3 4 Preparat...

Страница 8: ...Sliding base 29 4 8 3 3 Metal base 30 4 8 3 4 Anchor bolts 30 4 8 4 Natural frequency of the base 30 4 8 5 Leveling 30 4 8 6 Alignment 30 4 8 7 Doweling 31 4 8 8 Couplings 31 4 8 8 1 Direct coupling...

Страница 9: ...ontal bearings 42 7 10 1 10 Disassembly vertical bearings 43 7 10 1 10 1 Before disassembling 43 7 10 1 10 2 Lower bearing disassembly 44 7 10 1 10 3 Upper bearing disassembly 44 7 10 1 11 Bearing ass...

Страница 10: ......

Страница 11: ...bout motors with major special features is necessary consult WEG All procedures and standards contained in this manual must be observed in order to ensure proper operation of the motor and the safety...

Страница 12: ...sures during installation for example keep people away avoid contact of children etc Those responsible for the safety of the installation must ensure that Only qualified personnel install and operate...

Страница 13: ...or terminals within the limits in accordance with the IEC60034 1 standard Voltage may vary within a range of 10 of the rated value Frequency may vary within a range of 5 to 3 of the rated value Figure...

Страница 14: ...of the motor must be carried out after removing the package The shaft locking system must be removed just before the installation and stored to be used in future transportation of the motor 3 2 HANDL...

Страница 15: ...the machined parts must be repaired 3 3 1 Outdoor storage The motor must be stored in a dry location free of flooding and vibrations Repair any damages on the package before storing the motor which i...

Страница 16: ...that additional protections be added to the motor package during the storage period as follows A closed wooden crate or the like with an electrical installation that allows the energization of the sp...

Страница 17: ...stored for a period exceeding two years the rolling bearings must be disassembled washed inspected and relubricated 3 3 3 6 Terminal box When the insulation resistance of the motor windings is measur...

Страница 18: ...X Whenever necessary SPACE HEATER Check the operating conditions X Measure the circuit voltage and frequency X Check the function of the signal system if any X WHOLE MOTOR Perform external cleaning X...

Страница 19: ...3 3 4 2 Bearing lubrication Use the lubricant specified for bearing lubrication Information on the bearings and lubricants are indicated on the bearing nameplates and the lubrication must be done as d...

Страница 20: ...lation resistance Failure to comply with these procedures may result in personal injury 4 4 2 General considerations When the motor is not immediately put into operation it must be protected against m...

Страница 21: ...ommended to measure the insulation resistance of thermal protectors 4 4 5 Polarization Index The polarization index is defined by the ratio between the insulation resistance measured in 10 minutes and...

Страница 22: ...rmistors PTC or NTC Are thermal detectors composed of semiconductors that vary their resistance sharply when they reach a certain temperature Thermistors are connected in series or independently accor...

Страница 23: ...p temperatures must not exceed the maximum admissible temperatures for the stator winding insulation class and for the bearings considering the lubrication type and system according to Table 4 5 Table...

Страница 24: ...1 145 68 120 146 06 146 44 146 81 147 19 147 57 147 94 148 32 148 70 149 07 149 45 130 149 82 150 20 150 57 150 95 151 33 151 70 152 08 152 45 152 83 153 20 140 153 58 153 95 154 32 154 70 155 07 155...

Страница 25: ...oling system informed on the motor cooling system nameplate must be strictly followed The water inlets and outlets must not be obstructed because it can cause overheating or even lead to burning the m...

Страница 26: ...r drive end Motors with a single rotation direction must only rotate in the indicated direction since fans and other devices are unidirectional In order to operate the motor in the rotation direction...

Страница 27: ...1 1 Stator connection diagrams 3 TERMINALS 6 TERMINALS 6 TERMINALS DAHLANDER Y LOWER SPEED YY HIGHER SPEED Y LOWER SPEED YY LOWER SPEED HIGHER SPEED 3 TERMINALS NEUTRAL 9 TERMINALS 12 TERMINALS YY Y Y...

Страница 28: ...connections 4 7 2 3 Rotation direction The rotation direction is indicated on the nameplate and must be observed looking to the shaft end at the motor drive end The rotation direction must be checked...

Страница 29: ...ion blocks and the mortar Fasten the foundation blocks to the motor feet using bolts Use shims of different thicknesses total thickness of approximately 2 mm between the motor feet and the foundation...

Страница 30: ...next The first natural frequency of the base or foundation first order natural frequency of the base must be out of the range from 0 8 to 1 25 times any of the potential excitation frequencies above...

Страница 31: ...e value allowed by the coupling manufacturer It is recommended to keep a safety margin for these values In the alignment leveling the influence of the temperature on the motor and the driven machine m...

Страница 32: ...ontrolled with the insertion of a paper strip on which the trace of all teeth shows up after a gear turn 4 8 8 3 Belt drive Figure 4 14 Belt drive When a reduction or increase in speed is required the...

Страница 33: ...Since induction motors have a high starting current the time spent to accelerate loads with high inertia results in a quick rise of the motor temperature If the intervals between successive starts ar...

Страница 34: ...r cooling water supply system 12 Motor air inlets and outlets must be unobstructed 13 The moving parts of the motor must be protected to prevent accidents 14 Check if the power supply voltage and freq...

Страница 35: ...differential pressure at the water inlet and outlet be measured and recorded periodically These values must be periodically compared to the original value and an increase in the pressure differential...

Страница 36: ...peed the stator magnetic field speed will be equal to the rotor speed and thus there will be no current induction on the rotor and consequently no energy will be generated 6 4 2 Slip The asynchronous...

Страница 37: ...ation resistance measurements must be done at regular intervals especially during humid weather and after prolonged motor stoppages Low values or sudden variations in the insulation resistance must be...

Страница 38: ...otor If the motor remains stopped in environments with negative temperatures the freezing of the motor cooling circuit water must be prevented This can be done by draining all the water from the frame...

Страница 39: ...0 C 0 63 Between 80 and 90 C 0 40 Between 90 and 100 C 0 25 Between 100 and 110 C 0 16 7 10 1 2 Procedures for rolling bearing relubrication 1 Remove the drain plug 2 Clean with a cotton cloth around...

Страница 40: ...rval must be corrected by multiplying the interval informed on the bearing nameplate by the multiplication factor informed in Table 7 2 3 Use the correct procedure to change the grease according to se...

Страница 41: ...1200 1200 1500 900 900 6252 190 1000 1000 900 900 900 6315 30 3000 3000 3000 1800 1800 6316 35 3000 3000 1800 1800 1800 6317 40 3000 3000 1800 1800 1800 6319 45 1800 1800 1800 1800 1800 6320 50 1800...

Страница 42: ...7 10 1 7 Low temperature greases Table 7 4 Grease for application at low temperatures Manufacturer Grease Constant operating temperature C Application Exxon Mobil MOBILITH SHC 100 Lithium Soap and Sy...

Страница 43: ...following guidelines 1 Remove the screws 4 from the outer and inner bearing caps 5 and 11 2 Remove the outer bearing cap 5 3 Remove the screw 6 that fixes the grease flinger 7 4 Remove the grease fli...

Страница 44: ...earing cap 7 4 Remove the KMT nut 9 5 Remove the screws 11 and 12 and remove the bearing hub 6 Remove the upper end shield 14 7 Move the intermediate ring and the inner bearing cap away from the beari...

Страница 45: ...ated bearing Disassembly instructions If it is necessary to remove the Pt100 for bearing maintenance proceed according to the following instructions Remove the Pt100 carefully locking the locknut 3 an...

Страница 46: ...sories 4 Remove the grease nipple extenders and the device to remove the grease from the bearings 5 Remove the bearing temperature sensors and the grounding brush if any 6 In order to prevent damages...

Страница 47: ...earing 6 and the lower end shield 7 8 Remove the shaft protection cover 12 and the fastening nut of the upper rolling bearing 13 9 Disassemble the upper bearing 9 and the upper end shield 8 10 In orde...

Страница 48: ...2 70 or above Yield Strength 33 33 Lubricant Dry Molycote 1000 Dry Molycote 1000 Diam Pitch mm Screws tightening torque Nm M3 0 5 0 6 0 5 0 48 0 32 M4 0 7 1 5 1 1 1 0 76 M5 0 8 3 2 2 2 1 5 M6 1 5 2 3...

Страница 49: ...on of the shaft wear incrustations x BEARINGS Control of noise vibration leaks and temperature x Lubricant quality control x Lubricant change According to the period indicated on the bearing nameplate...

Страница 50: ...fter the start Check the power cables The stator current oscillates under load with double the slip frequency The motor presents a humming noise during starting Rotor winding is interrupted Check and...

Страница 51: ...t the stator Check the air gap operating conditions vibration etc bearing conditions The operating condition does not correspond to the nameplate data Keep the operating condition according to the nam...

Страница 52: ...www weg net 52 l Installation operation and maintenance manual Squirrel cage motor W Line Horizontal and vertical 11239449 11 DECLARATION OF CONFORMITY...

Страница 53: ...m and plastic The electric motor in general is a product that has a long useful life however when it must be disposed WEG recommends that the materials of the packaging and of the product be properly...

Страница 54: ...e and is in lieu of all other warranties expressed or implied written or oral There are no implied warranties of merchantability or fitness for a particular purpose that apply to this sale No employee...

Страница 55: ...remona Phone 39 374 340 404 www ferrarisrl it STIAVELLI IRIO S P A Via Pantano Blocco 16 Capalle 50010 Campi Bisenzio FI Phone 39 55 898 448 www stiavelli com JAPAN WEG ELECTRIC MOTORS JAPAN CO LTD Yo...

Отзывы: