HMI and Basic Programming
4-2 | CFW500
4
Inverter status
Secondary display
Unit of measurement
(it refers to the value
of the main display)
Bar to
monitor the
variable
Menu (to select the
parameter groups) –
only one parameter
group is shown at a
time.
Main display
Figure 4.2:
Display areas
Parameter groups available in the field Menu:
PARAM:
all parameters.
READ:
read only parameters.
MODIF:
parameters modified in relation to the factory default.
BASIC:
parameters for basic application.
MOTOR:
parameters related to the motor control.
I/O:
parameters related to digital and analog inputs and outputs.
NET:
parameters related to the communication networks.
HMI:
parameters to configure the HMI.
SPLC:
parameters related to the SoftPLC.
STARTUP:
parameters for oriented Start-up.
Status of the inverter:
LOC:
command source or Local references.
REM:
command source or Remote references.
:
direction of rotation by means of arrows.
CONF:
CONFIG status active.
SUB:
undervoltage.
RUN:
execution.
4.3 OPERATING MODES OF THE HMI
The monitoring mode allows the user to view up to three variables on the main display, secondary display and
bar graph. Such fields of the display are defined in
The setting mode is composed of three levels:
Level 1
allows the user to select the menu items to direct the browsing of the parameters.
Содержание CFW500 V1.8X
Страница 2: ......
Страница 4: ......
Страница 8: ...Contents...
Страница 34: ...General Information 2 4 CFW500...
Страница 38: ...About the CFW500 3 4 CFW500 3...
Страница 42: ...HMI and Basic Programming 4 4 CFW500 4...
Страница 52: ...Programming Basic Instructions 5 10 CFW500 5...
Страница 56: ...Identification of the Inverter Model and Accessories 6 4 CFW500 6...
Страница 76: ...Available Motor Control Types 8 4 CFW500 8...
Страница 84: ...V f Scalar Control 9 8 CFW500 9...
Страница 170: ...Communication 17 8 CFW500 17...