Programming Basic Instructions
5-6 | CFW300
5
5.4 ENGINEERING UNITS FOR SOFTPLC
This parameter group allows the user to configure the engineering units for indication on the HMI of the user's
parameters of the SoftPLC module.
P510 - SoftPLC Engineering Unit
Adjustable
Range:
0 = Without Unit
1 = A
2 = V
3 = Hz
4 = s
5 = %
6 = ºC (°F)
7 = rpm
Factory
Setting:
0
Properties:
Description:
This parameter selects the engineering unit that will be viewed on the HMI, that is, any user’s parameter of the
SoftPLC which is related to the SoftPLC engineering unit will be viewed in this format.
P511 - SoftPLC Indication Form
Adjustable
Range:
0 = wxyz
1 = wxy.z
2 = wx.yz
3 = w.xyz
Factory
Setting:
1
Properties:
Description:
This parameter selects the decimal point that will be viewed on the HMI, that is, any user’s parameter of the
SoftPLC which is related to the SoftPLC indication form will be viewed in this format.
NOTE!
The engineering unit may be selected in the “Configuration of the User’s Parameters” window in
the WPS program.