Faults and Alarms
14-8 | CFW300
14
P358 - Encoder Fault Configuraton
Adjustable
Range:
0 = Off
1 = F067 ON
2 = F079 ON
3 = F067, F079 ON
Factory
Setting:
3
Properties:
cfg
Description:
This parameter allows individually disabling the fault detection by software: a) F067 - Inverted Encoder/Motor
Wiring and b) F079 - Encoder Signal Fault. The verification by software of faults F067 and F079 will remain
disabled when P358 = 0.